Contact American Megatrends to get the optional megamgr configuration utility.
The MegaRAID controller cannot be configured by editing the /kernel/drv/mega.conf file.
Follow this procedure to configure and use more than one logical drive. If the /kernel/drv/cmdk.conf file is not carefully edited, the system may panic upon reboot.
Press Control-M while the system is starting up to configure the controller and all logical drives.
Install the Solaris software and reboot.
You will only see a single logical drive available during installation.
Open /kernel/drv/cmdk.conf and add additional drives by duplicating the existing entry for target=0 and incrementing the lun field by one for each additional logical drive you want the Solaris software to recognize.
For example, if you have a total of three logical drives configured on your adapter, you would add the following lines:
name="cmdk" class="scsi" target=0 lun=1 scsi_audio="sccd_sony","sccd_std"; name="cmdk" class="scsi" target=0 lun=2 scsi_audio="sccd_sony","sccd_std"; |
Reboot.
After the system reboots, you can use additional drives.