Configuring Java CAPS Environment Components for Communications Adapters

HL7 Inbound Adapter - Sequence Number Protocol

The HL7 Inbound Adapter - Sequence Number Protocol provides configuration settings used to help prevent duplication of data.

This section of the TCP/IP HL7 Adapter Environment properties contains the top-level parameters displayed in the following table.

Table 10 Environment - HL7 Inbound Adapter - Sequence Number Protocol

Name 

Description 

Required Value 

Sequence Number File Location

Specifies the location of the sequence number file (a local directory). This is required when the Sequence Number Protocol is enabled. The sequence number file is a non-volatile directory that stores the sequence number files that are used to persist the HL7 sequence number. This unique base file name is automatically generated according to Project/Collaboration information. 

For the Inbound Adapter the file names are created as follows: 


<Project name> + <deployment name> + 
<external application node name>  +  
<Collaboration name> + .seqno

For example: 


 prjHL7Inbound_dpIn_eaHL7Inbound_
jcdHL7inbound1.seqno

The path and directory where the sequence number file is located. 

The default setting is: 

/temp/hl7inbound/seq