Sun Adapter for TCP/IP HL7 User's Guide

HL7 Inbound Adapter - Sequence Number Protocol

The following table lists and describes the property that appears on the Sequence Number Protocol page of the Properties Editor accessed from the Environment. Sequence numbering helps prevent duplication of data.

Table 53 Environment - HL7 Inbound Adapter - Sequence Number Protocol

Name 

Description 

Sequence Number File Location

The location of the sequence number file (a local directory). This is required when the Sequence Number Protocol is enabled. The sequence number folder is a nonvolatile directory that stores the sequence number files used to persist the HL7 sequence number. The unique base file name is automatically generated according to project or Collaboration information. 

For the inbound Adapter the file names are created as follows: 

ProjectName + DeploymentName + ExternalApplicationName + CollaborationName + .seqno

For example, prjHL7Inbound_dpIn_eaHL7Inbound_ jcdHL7inbound1.seqno

The default setting is /temp/hl7inbound/seq.