The SUNW.sapenq resource type represents the SAP enqueue server in a Sun Cluster configuration. The extension properties of this resource type are as follows:
The child process monitoring level for the Process Monitor Facility (PMF). This property is equivalent to the -C option of pmfadm.
The default value of -1 indicates that child process monitoring is not to be performed. Positive values indicate the desired level of child process monitoring.
Integer
-1
No range defined
Any time
The two-digit instance number for the SAP enqueue server. This number is the value of SAPSYSTEM in the SAP profile for SAP enqueue server.
String
No default defined
Not applicable
When disabled
The full path to the SAP enqueue server profile.
String
No default defined
Not applicable
When disabled
The full path to the SAP enqueue server executable.
String
No default defined
Not applicable
When disabled
The full path to the SAP enqueue server monitor executable.
String
directory/ensmon, where directory is the full path to the directory where the SAP enqueue server executable is stored, as specified by the extension property Enqueue_Server.
Not applicable
When disabled
The directory for the startup and monitor log files.
String
The home directory of the administration user, as specified by the extension property SAP_User.
Not applicable
When disabled
The maximum number of restarts by the Process Monitor Facility (PMF) that are allowed for the SAP enqueue server fault monitor.
Integer
4
No range defined
Any time
The interval in minutes between restarts of the SAP enqueue server fault monitor.
Integer
2
No range defined
Any time
The timeout value in seconds that the SAP enqueue server fault monitor uses to probe an SAP enqueue server instance.
Integer
120
Minimum = 2; no maximum defined
Any time
The administration user for the SAP enqueue server.
String, where letters are in lowercase
No default defined
Not applicable
When disabled
The signal that is sent to the application to stop the SAP enqueue server application.
Integer
2 (equivalent to SIGINT)
1–37
When disabled