6000

enclosure_name: Unable to access disk diskname (enclosure name, Front|Rear, Slot)

Bad disk. 

Contact your authorized Sun service representative.

6001

Unable to access any disk through host adapter: host adapter device

Bad host adapter. 

Run SunVTS socaltest on the host adapter.

6003

enclosure_name: Unable to access disk diskname (enclosure_name, Front|Rear, Slot) through Host adapter device name. This disk is still accessible through other path(s)

Port A or B of the disk is faulty. 

Contact your authorized Sun service representative.

6004

enclosure_name: Failed to determine the location of disk diskname

Invalid device name. 

Contact your authorized Sun service representative.

6005

enclosure_name: Could not access diskname (enclosure_name, Front|Rear, Slot) through Host adapter device name

Host adapter is faulty. 

Contact your authorized Sun service representative.

6006

enclosure_name: Disk diskname cannot be accessed through Host adapter device name

Critical failure in the Interface Board (in the enclosure) through which this disk is accessed. 

Contact your authorized Sun service representative.

6007

enclosure_name: Disk diskname cannot be accessed through Host adapter device name

Interface Board (in the enclosure) through which this disk is accessed is not installed. 

 

6008

enclosure_name: Disk diskname cannot be accessed through Host adapter device name

Critical failure (transmitter fault) in the GBIC module (in the enclosure) through which this disk is accessed. 

Contact your authorized Sun service representative.

6009

enclosure_name: Disk diskname cannot be accessed through Host adapter device name

Loss of light at the GBIC module (in the enclosure) through which this disk is accessed.

Contact your authorized Sun service representative.

Faulty cable.

Faulty GBIC module on the host side.

6013

enclosure_name: Could not access diskname (enclosure name, Front|Rear, Slot) through Host adapter device name

Faulty GBIC module on host side. 

 

Bad cable connection. 

6014

enclosure_name: Could not access diskname (enclosure name, Front|Rear, Slot) through Host adapter device name

Faulty Host Adapter. 

 

Faulty GBIC on host side. 

Faulty cable. 

6015

enclosure_name: Could not access diskname through Host adapter device name

Disk is not installed. 

 

6016

enclosure_name: Could not access diskname through Host adapter device name

Disk detected to be installed, but may be bypassed or powered off. 

 

6017

enclosure_name: Disk diskname cannot be accessed through Host adapter device name

Critical failure in the enclosure backplane through which this disk is accessed. 

Contact your authorized Sun service representative.

6018

enclosure_name: Disk diskname cannot be accessed through Host adapter device name

Enclosure backplane through which this disk  

is accessed is not installed. 

 

6019

enclosure_name: Disk diskname cannot be accessed through Host adapter device name

GBIC module (in the enclosure) through which this disk is accessed is not installed. 

 

6020

enclosure_name: Cannot communicate with the enclosure via Host adapter device name

Critical failure in the Interface Board (top/bottom one in enclosure). 

Contact your authorized Sun service representative.

6021

enclosure_name: Cannot communicate with the enclosure via Host adapter device name

Interface board (top or bottom) is not installed in the enclosure. 

 

6022

enclosure_name: Cannot communicate with the enclosure via Host adapter device name; possibly connected to location GBIC in the enclosure

Critical failure (transmitter fault in the GBIC module in the enclosure). 

Contact your authorized Sun service representative.

6023

enclosure_name: Cannot communicate with the enclosure via Host adapter device name; possibly connected to location GBIC in the enclosure

Signal level too low at the GBIC module in the enclosure. 

Ensure the cables are properly connected. Contact your authorized Sun service representative.

 

Faulty cable or cable disconnected. 

 

Faulty GBIC module on the  

host side. 

6024

enclosure_name: Cannot communicate with the enclosure via Host adapter device name

GBIC module (location) is not installed in the enclosure.

 

6026

enclosure_name: Failed to Restore|Toggle disk (Front|Rear, slot slot_number) state. Expected:

Port A: Bypassed|Connected; Port B: Bypassed|Connected; Observed:

Port A: Bypassed|Connected; Port B: Bypassed|Connected

Error in Enclosure Services or Enclosure Element. 

Contact your authorized Sun service representative.

6027

enclosure_name: Unable to access disk diskname

(Front|Rear slot slot_number) through port A|B even after bringing the port online

Error in Enclosure Services or Enclosure Element. 

Contact your authorized Sun service representative.

6028

enclosure_name: Disk access succeeded for diskname (Front|Rear slot slot_number) through port A|B

even after requesting that the port be bypassed

Error in Enclosure Services or Enclosure Element. 

Contact your authorized Sun service representative.

6035

enclosure_name: Cannot access enclosure through

Host adapter device name

Critical GBIC failure in the enclosure; location GBIC:  

disabled|enabled Signal: signal_level; Transmitter:

Failed|OK; location GBIC: disabled|enabled

Signal: signal_level; Transmitter: Failed|OK

Contact your authorized Sun service representative.

6036

enclosure_name: Critical condition detected in enclosure!

 

Run this test in 'Functional' mode for more information. Contact your authorized Sun service representative.

8001

Could'nt determine the host adapter through which diskname being accessed

Software error. 

Contact your authorized Sun service representative.

8003

Internal error

Software error in test. 

Contact your authorized Sun service representative

system error message. 

8004

enclosure_name: Could not communicate with enclosure via Host adapter device name

Bad connection. 

Ensure the cables are properly connected. Contact your authorized Sun service representative. 

8005

Could not communicate with the enclosure

Faulty connection. 

Ensure the cables are properly connected. Run SunVTS socaltest to verify the host adapter. Contact your authorized Sun service representative.