SunVTS 3.0 Test Reference Manual

gemtest Error Messages

Table 18-3 gemtest Error Messages

 

Error Message 

Probable Cause(s) 

Recommended Action 

 6000 Timed out for receiving pkt number Card and/or driver not configured properly. Configure driver or reseat card. Check loopback connector. If the problem persists, contact your authorized Sun service Provider.
 6001 system error System may have run out of memory. Reduce the number of processes currently running or increase system memory.
 6002 Data mismatch between transmitted and received pkt data Link loss,CRC error,Alignment Error. If the frequency of errors is large, replace the card and/or contact your authorized Sun service Provider.
 8000 errmsg for device Card not present Check for card.
 8001 Memory allocation failure System ran out of memory. Reduce the number of processes currently running. Increase system memory.
 8002 No card found No card found. Install card.
 8003 Failed to get the link up Loopback connector not connected. Faulty loopback connector. Check it an replace it if necessary. If problem persists, contact your authorized Sun service Provider
 8004 Transmit failed error STREAMS was unable to accept more data, perhaps due to insufficient STREAMS memory resources. Reduce the system load.
 8005 Receive failed, error for pkt number  Try again, if the problem persists, then it is a system error. Contact your authorized Sun service provider.
 8006DLPI error for device string Wrong Instance number X specified in geX Specify correct instance number.