/opt/SUNWvts/bin/spiftest standard_arguments -o dev=device_name, M=test_mode,Ptr=enable/disable,B=baud_rate,Size=character_size,S=#of_stop_bits, Parity=parity,F=flow_control,Data=test_pattern,sp=serial_port
Table 33-3 spiftest Command Line Syntax
Argument |
Explanation |
---|---|
dev=device_name |
Specifies the serial ports in SBus card slots (0-63) being tested. Since there is no default, you must type a board name: |
|
stc0 = the 8 serial ports in the first card |
|
stc1 = the 8 serial ports in the second card |
|
stc2 = the 8 serial ports in the third card |
|
stc3 = the 8 serial ports in the fourth card |
|
stc4 = the 8 serial ports in the fifth card |
|
stc5 = the 8 serial ports in the sixth card |
|
stc6 = the 8 serial ports in the seventh card |
|
stc7 = the 8 serial ports in the eighth card |
M=test_mode |
Specifies Internal, 96_pin_Loopback, 25_pin_loopback, or Echo_TTY test mode. |
Ptr=printer_test |
Enables or disables the Printer subtest. |
B=baud_rate |
Sets the baud rate to 110, 300, 600, 1200, 2400, 4800, 9600, 19200, or 38400; the default is 9600. To use the 38400 rate, only one port at a time can be tested, and the Internal test must be disabled. |
Stop=#of_stop_bits |
Toggles the number of stop bits between 1 or 2; the default is 1. |
Size=character_size |
Sets character size as a number between 5 and 8. |
P=parity |
Specifies the parity as none, odd, or even; the default is none. |
F=flow_control |
Specifies flow control as xonxoff,rtscts, or both. |
Data=test_pattern |
Specifies test pattern as 0x55555555, 0xAAAAAAAA, or random. |
sp=serial_port |
Specifies the terminal and serial port number, such as term/3. |
64-bit tests are located in the sparcv9 subdirectory: /opt/SUNWvts/bin/sparcv9/testname. If a test is not present in this directory, then it may only be available as a 32-bit test. For more information refer to "32-Bit and 64-Bit Tests".