Solaris 7 (Intel Platform Edition) Device Configuration Guide

DPT PM2022, PM2042W, PM2122, PM2142W SCSI and PM3222, PM3222UW, PM3332UW SCSI RAID HBAs

Solaris Device Driver:

dpt

Device Types:

SCSI, SCSI RAID 

Adapters:

DPT PM2022, PM2042W, PM2122, PM2142W SCSI  

DPT PM3222, PM3222UW, PM3332UW SCSI RAID 

Bus Type:

EISA 

Preconfiguration Information

Supported Settings

o WD1003 Boot Address: 

Disabled (Secondary) 

o IRQ Level: 

Any legal value between 11 and 15, except 14 


Note -

Make sure you use edge-triggered interrupts.


o IDE Boot Address: 

Disabled 

o SCSI BIOS ROM Address: 

Default 

o HBA SCSI ID: 

Default 7 

Known Problems and Limitations

ERROR: Could not create Fdisk partition table on disk
ERROR: Could not label the disks

Configuration Procedure

Run the DPT SCSI Storage Manager Utility, DPTMGR, under DOS, and select Solaris as the operating environment. See Chapter 4 of DPT SmartCache III User's Manual for instructions. An error message similar to this may be displayed while DPTMGR is running.

Unable to find any drivers in the DRIVERS Directory ......

This message can be ignored.

Special Case

When using the ECU supplied by DPT in conjunction with a configuration file, you enter emulation information as part of the configuration process. When you configure two drives, both should be "disabled." When asked for drive types for drives 0 and 1, type 0. This indicates "no drives present" and disables the WD1003 emulation mode of the adapter, allowing correct operation of the native mode driver.