This chapter provides information on how to install the patch necessary for adding OS services to your server and how to upgrade clients after a server upgrade.
This section supplements "Adding Server and Client Support Task Map" in System Administration Guide, Volume I on the Solaris 7 Documentation CD.
When you install diskless clients or Solstice AutoClientTM systems from a server running Solstice AdminSuite 2.3 software, you need to install Solstice AdminSuite 2.3 patch number 104468-11 (SPARC) or 104469-11 (Intel) or any subsequent revision of this patch. You will find the patch and installation instructions
For SPARC: http://access1.sun.com/private-cgi/patch2html?README.104468-11
For Intel: http://access1.sun.com/private-cgi/patch2html?README.104469-11
If you are unable to obtain the patch from access1.sun.com, go through your normal support channel.
If you are using Solstice AdminSuite software with a patched Solaris release from which it is inadvisable or impossible to remove all the patches, then you need the following file to add OS services:
/var/sadm/patch/.mu_applied
This file is automatically created by the following Maintenance Update releases:
Solaris 2.5.1: MU3, MU4, and MU5
Solaris 2.6: MU1 and MU2
Solaris 7: MU1, MU2, MU3, and MU4
With this workaround, Solstice AdminSuite software is unable to track all the patches in a system. Use admclientpatch to add or remove patches to or from the system.
This section supplements "Upgrading a System" in the Solaris 7 (SPARC Platform Edition) Installation Library and the Solaris 7 (Intel Platform Edition) Installation Library.
After you upgrade a server, you need to apply the patches in the Patches directory on the Solaris 7 11/99 CD to the clients connected to that server.
For more information on adding patches to clients, see the man page patchadd(1M). For more information on server upgrades, see the man page server_upgrade(1M).