SCSI controller c1 provides an example of connecting a SCSI controller.
Only SCSI attachment points are listed. The attachment points displayed on your system will depend on your system configuration.
Become superuser.
Verify the device is disconnected before connecting it.
# cfgadm -al Ap_Id Receptacle Occupant Condition c0 connected configured unknown c0::dsk/c0t0d0 connected configured unknown c0::rmt/0 connected configured unknown c1 disconnected configured unknown c1::dsk/c1t10d0 disconnected configured unknown c1::dsk/c1t4d0 disconnected configured unknown |
Connect a SCSI controller.
# cfgadm -c connect c1 |
Verify the SCSI controller is connected.
# cfgadm -al Ap_Id Receptacle Occupant Condition c0 connected configured unknown c0::dsk/c0t0d0 connected configured unknown c0::rmt/0 connected configured unknown c1 connected configured unknown c1::dsk/c1t10d0 connected configured unknown c1::dsk/c1t4d0 connected configured unknown |