Sun Cluster 3.0-3.1 With Sun StorEdge T3 or T3+ Array Manual for Solaris OS

Maintaining Sun StorEdge T3 or T3+ Storage Array Components

This section contains the procedures about how to maintain a storage array. The following table lists these procedures. This section does not include a procedure about how to add a disk drive and a procedure about how to remove a disk drive, because a storage array only operates when fully configured.


Caution – Caution –

If you remove any field-replaceable unit (FRU) for an extended period of time, thermal complications might result. To prevent this complication, the storage array is designed so that an orderly shutdown occurs. This shutdown occurs when you remove a component for longer than 30 minutes. Therefore, a replacement part must be immediately available before you start an FRU replacement procedure. You must replace an FRU within 30 minutes. If you do not replace the FRU within this time, the storage array, and all attached storage array, shut down and power off.



Note –

When you upgrade firmware on a storage device or on an enclosure, redefine the stripe size of a LUN, or perform other LUN operations, a device ID might change unexpectedly. When you perform a check of the device ID configuration by running the scdidadm -c command, the following error message appears on your console if the device ID changed unexpectedly.


device id for nodename:/dev/rdsk/cXtYdZsN does not match physical 
device's id for ddecimalnumber, device may have been replaced.

To fix device IDs that report this error, run the scdidadm -R command for each affected device.


Table 2–1 Task Map: Maintaining a Storage Array

Task 

Information 

Replace a disk drive. 

How to Replace a Disk Drive

Replace a host-to-hub/switch fiber-optic cable. 

Replacing a Node-to-Switch Component

Replace an FC host adapter GBIC or an SFP. 

Replacing a Node-to-Switch Component

Replace an FC hub/switch GBIC or an SFP that connects an FC hub/switch to a host. 

Replacing a Node-to-Switch Component

Replace a hub/switch-to-storage array fiber-optic cable. 

How to Replace a Hub/Switch or Hub/Switch-to-Array Component in a Single-Controller Configuration

Replace an FC hub/switch GBIC or an SFP that connects the FC hub/switch to a storage array. 

How to Replace a Hub/Switch or Hub/Switch-to-Array Component in a Single-Controller Configuration

Replace an FC hub/switch. 

How to Replace a Hub/Switch or Hub/Switch-to-Array Component in a Single-Controller Configuration

Replace an FC switch. 

This procedure applies to SAN-configured clusters only. 

How to Replace a Hub/Switch or Hub/Switch-to-Array Component in a Single-Controller Configuration

Replace an FC hub/switch power cord. 

How to Replace a Hub/Switch or Hub/Switch-to-Array Component in a Single-Controller Configuration

Replace a media interface adapter (MIA) on a storage array. 

This procedure does not apply to storage arrays. 

How to Replace a Hub/Switch or Hub/Switch-to-Array Component in a Single-Controller Configuration

Replace a storage array controller. 

How to Replace a Storage Array Controller

Replace a chassis. 

How to Replace a Chassis

Replace a host adapter. 

How to Replace a Host Adapter

Remove a storage array. 

How to Remove a Storage Array in a Single-Controller Configuration

Remove a storage array. 

How to Remove a Storage Array in a Single-Controller Configuration

Remove a partner group. 

How to Remove a Partner Group

Add a node to the storage device.

Sun Cluster system administration documentation 

 

Remove a node from the storage device.

Sun Cluster system administration documentation 

Sun StorEdge T3 and T3+ Array FRUs

The following is a list of administrative tasks that require no cluster-specific procedures. See the Sun StorEdge T3 and T3+ Array Installation, Operation, and Service Manual for the following procedures.

Upgrading a Sun StorEdge T3 array controller to a Sun StorEdge T3+ array controller requires no cluster-specific procedures. See the Sun StorEdge T3 Array Controller Upgrade Manual for the following procedures.

ProcedureHow to Replace a Disk Drive

Use this procedure to replace a failed disk drive in a storage array in a running cluster.


Note –

Sun storage documentation uses the following terms:

This manual uses logical volume to refer to all such logical constructs.


Steps
  1. If the failed disk drive affect the storage array logical volume's availability, If yes, use volume manager commands to detach the submirror or plex.

    For more information, see your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation.

  2. Check if the logical volume (in Step 1) is a quorum device.


    # scstat -q
    

    If yes, choose and configure another device to be the new quorum device. Remove the old quorum device. For procedures about how to add and remove quorum devices, see your Sun Cluster system administration documentation.

  3. Replace the failed disk drive.

    For instructions, refer to the Sun StorEdge T3 and T3+ Array Installation, Operation, and Service Manual.

  4. (Optional) If the new disk drive is part of a logical volume that you want to be a quorum device, add the quorum device.

    For the procedure about how to add a quorum device, see your Sun Cluster system administration documentation.

  5. Did you detach a submirror or plex in Step 1?

    • If no, you are finished with this procedure.

    • If yes, use volume manager commands to reattach the submirror or plex.

      For more information, see your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation.

Replacing a Node-to-Switch Component

Use this procedure to replace a node-to-switch component that has failed or that you suspect might be contributing to a problem.


Note –

Node-to-switch components that are covered by this procedure include the following components:

For the procedure about how to replace a host adapter, see How to Replace a Host Adapter.


This procedure defines Node A as the node that is connected to the node-to-switch component that you are replacing. This procedure assumes that, except for the component you are replacing, your cluster is operational.

Ensure that you are following the appropriate instructions:

ProcedureHow to Replace a Node-to-Switch Component in a Cluster That Uses Multipathing

Steps
  1. Is your configuration active-passive?

    If yes, and the active path is the path that needs a component replaced, make that path passive.

  2. Replace the component.

    Refer to your hardware documentation for any component-specific instructions.

  3. (Optional) If your configuration is active-passive and you changed your configuration in Step 1, switch your original data path back to active.

ProcedureHow to Replace a Node-to-Switch Component in a Cluster Without Multipathing

Steps
  1. Check if the physical data path failed.

    If no, proceed to Step 2.

    If yes:

    1. Replace the component.

      Refer to your hardware documentation for any component-specific instructions.

    2. Fix the volume manager error that was caused by the failed data path.

    3. (Optional) If necessary, return resource groups and device groups to this node.

    You have completed this procedure.

  2. Determine the resource groups and device groups that are running on Node A.


    # scstat
    
  3. Move all resource groups and device groups to another node.


    # scswitch -s -h from-node
    
  4. Replace the node-to-switch component.

    Refer to your hardware documentation for any component-specific instructions.

  5. (Optional) If necessary, return the resource groups and device groups that you identified in Step 2 to Node A.


    # scswitch -z -g resource-group -h nodename
    # swswitch -z -D device-group -h nodename
    

ProcedureHow to Replace a Hub/Switch or Hub/Switch-to-Array Component in a Single-Controller Configuration

Use this procedure to replace a hub/switch or the following hub/switch-to-array components for an array in a single-controller configuration. To replace these components for an array in a partner-group configuration, see How to Replace an FC Switch or Storage Array-to-Switch Component in a Partner-Group Configuration. You can use storage array in single-controller configuration with FC switches when you create a SAN.

Steps
  1. Detach the submirrors on the storage array. This array is connected to the hub/switch-to-array fiber-optic cable that you are replacing. Detach the submirrors to stop all I/O activity to this storage array.

    For more information, see your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation.

  2. Replace the hub/switch or hub/switch-to-array component.

    • For the procedure about how to replace a fiber-optic cable, see the Sun StorEdge T3 and T3+ Array Configuration Guide.

    • For the procedure about how to replace an FC hub/switch GBIC or an SFP, an FC hub/switch, or an FC hub/switch power cord, see the documentation that shipped with your FC hub/switch hardware.

    • For the procedure about how to replace an MIA, see the Sun StorEdge T3 and T3+ Array Installation, Operation, and Service Manual.

    • If you are replacing FC switches in a SAN, follow the hardware installation and SAN configuration instructions in the documentation that shipped with your switch hardware.


      Note –

      If you are replacing an FC switch and you intend to save the switch configuration for restoration to the replacement switch, do not connect the cables to the replacement switch until after you recall the Fabric configuration to the replacement switch. For more information about how to save and recall switch configurations, see the documentation that shipped with your switch hardware.



      Note –

      Before you replace an FC switch, be sure that the probe_timeout parameter of your data service software is set to more than 90 seconds. If you increase the value of the probe_timeout parameter to more than 90 seconds, you avoid unnecessary resource group restarts. Resource group restarts occur when one of the FC switches is powered off.


  3. Reattach the submirrors to resynchronize the submirrors.

    For more information, see your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation.

ProcedureHow to Replace an FC Switch or Storage Array-to-Switch Component in a Partner-Group Configuration

Use this procedure to replace components for a storage array in a partner-group configuration in a running cluster. To replace components for arrays in a single-controller configuration, see How to Replace a Hub/Switch or Hub/Switch-to-Array Component in a Single-Controller Configuration. Use this procedure to replace the following storage array-to-switch components.

Steps
  1. Access the storage array. This storage array is connected to the FC switch or component that you are replacing.

  2. View the controller status for the two storage arrays in the partner group.

    For more information, see the Sun StorEdge T3 and T3+ Array Administrator's Guide.

  3. Are you replacing an FC switch or component that is attached to a storage array controller that is ONLINE or DISABLED?

    • If the controller is already DISABLED, skip to Step 5.

    • If the controller is ONLINE, disable the controller.

    For more information, see the Sun StorEdge T3 and T3+ Array Administrator's Guide.

  4. Verify that the controller's state has been changed to DISABLED.

  5. Replace the component by using the following references.

    • For the procedure about how to replace a fiber-optic cable between a storage array and an FC switch, see the documentation that shipped with your switch hardware.

    • For the procedure about how to replace a GBIC or an SFP on an FC switch, see the documentation that shipped with your FC switch hardware.

    • For the procedure about how to replace an FC switch, see the documentation that shipped with your switch hardware.


      Note –

      If you are replacing an FC switch and you intend to save the switch IP configuration for restoration to the replacement switch, wait to connect the cables to the replacement switch. Connect the cables to the replacement switch after you recall the Fabric configuration to the replacement switch. For more information about how to save and recall switch configurations, see the documentation that shipped with your switch hardware.



      Note –

      Before you replace an FC switch, be sure that the probe_timeout parameter of your data service software is set to more than 90 seconds. If you increase the value of the probe_timeout parameter to more than 90 seconds, you avoid unnecessary resource group restarts. Resource group restarts occur when one of the FC switches is powered off.


    • For the procedure about how to replace an MIA, see the Sun StorEdge T3 and T3+ Array Installation, Operation, and Service Manual.

    • For the procedure about how to replace interconnect cables, see the Sun StorEdge T3 and T3+ Array Installation, Operation, and Service Manual.

  6. If necessary, access the storage array. This storage array is the storage array in the partner group that is still online.

  7. Enable the storage array that you disabled in Step 3.

    For more information, see the Sun StorEdge T3 and T3+ Array Administrator's Guide.

  8. Verify that the controller's state has been changed to ONLINE.

ProcedureHow to Replace a Storage Array Controller

Steps
  1. Detach the submirrors on the storage array. This array is connected to the controller that you are replacing. Detach the submirrors to stop all I/O activity to this storage array.

    For more information, see your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation.

  2. Replace the controller.

    For the procedure about how to replace a storage array controller, see the Sun StorEdge T3 and T3+ Array Installation, Operation, and Service Manual.

  3. Reattach the submirrors to resynchronize the submirrors.

    For more information, see your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation.

ProcedureHow to Replace a Chassis

Use this procedure to replace a storage array chassis. This procedure assumes that you are retaining all FRUs other than the chassis and the midplane. To replace the chassis, you must replace both the chassis and the midplane because these components are manufactured as one part.


Caution – Caution –

You must be a Sun service provider to perform this procedure. If you need to replace a chassis, contact your Sun service provider.


Steps
  1. Detach the submirrors on the storage array. This array is connected to the chassis that you are replacing. Detach the submirrors to stop all I/O activity to this storage array.

    For more information, see your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation.

  2. Replace the chassis and the midplane.

    For the procedure about how to replace a storage array chassis, see the Sun StorEdge T3 and T3+ Array Field Service Manual.

  3. Reattach the submirrors to resynchronize the submirrors.


    Caution – Caution –

    The world wide names (WWNs) change as a result of this procedure. You must reconfigure your volume manager software to recognize the new WWNs.


    For more information, see your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation.

ProcedureHow to Replace a Host Adapter

Use this procedure to replace a failed host adapter in a running cluster. This procedure defines Node A as the node with the failed host adapter that you are replacing.

Before You Begin

This procedure relies on the following prerequisites and assumptions.

Steps
  1. Determine the resource groups and device groups that are running on Node A.

    Record this information because you use this information in Step 9 of this procedure to return resource groups and device groups to Node A.


    # scstat
    
  2. Move all resource groups and device groups off Node A.


    # scswitch -S -h nodename
    
  3. Shut down Node A.

    For the full procedure about how to shut down and power off a node, see your Sun Cluster system administration documentation.

  4. Power off Node A.

  5. Replace the failed host adapter.

    For the procedure about how to remove and add host adapters, see the documentation that shipped with your nodes.

  6. Do you need to upgrade the node's host adapter firmware?

    • If yes, boot Node A into noncluster mode. Proceed to Step 7.

      For more information about how to boot nodes, see your Sun Cluster system administration documentation.

    • If no, proceed to Step 8.

  7. Upgrade the host adapter firmware on Node A.

    PatchPro is a patch-management tool that eases the selection and download of patches required for installation or maintenance of Sun Cluster software. PatchPro provides an Interactive Mode tool especially for Sun Cluster. The Interactive Tool makes the installation of patches easier. PatchPro's Expert Mode tool helps you to maintain your configuration with the latest set of patches. Expert Mode is especially useful for obtaining all of the latest patches, not just the high availability and security patches.

    To access the PatchPro tool for Sun Cluster software, go to http://www.sun.com/PatchPro/, click Sun Cluster, then choose either Interactive Mode or Expert Mode. Follow the instructions in the PatchPro tool to describe your cluster configuration and download the patches.

    For third-party firmware patches, see the SunSolveSM Online site at http://sunsolve.ebay.sun.com.

  8. Boot Node A into cluster mode.

    For more information about how to boot nodes, see your Sun Cluster system administration documentation.

  9. Return the resource groups and device groups you identified in Step 1 to Node A.


    # scswitch -z -g resource-group -h nodename
    # scswitch -z -D device-group-name -h nodename
    

    For more information, see your Sun Cluster system administration documentation.

ProcedureHow to Remove a Storage Array in a Single-Controller Configuration

Use this procedure to remove a storage array and its submirrors from a running cluster. This procedure provides the flexibility to remove the host adapters from the nodes for the storage array that you are removing. To remove a partner group from the cluster, see How to Remove a Partner Group.


Note –

When you upgrade firmware on a storage device or on an enclosure, redefine the stripe size of a LUN, or perform other LUN operations, a device ID might change unexpectedly. When you perform a check of the device ID configuration by running the scdidadm -c command, the following error message appears on your console if the device ID changed unexpectedly.


device id for nodename:/dev/rdsk/cXtYdZsN does not match physical 
device's id for ddecimalnumber, device may have been replaced.

To fix device IDs that report this error, run the scdidadm -R command for each affected device.


This procedure defines Node A as the node with which you begin working. Node B is another node in the cluster.


Caution – Caution –

During this procedure, you lose access to the data that resides on the storage array that you are removing.


Steps
  1. Back up all database tables, data services, and volumes that are associated with the storage array. This storage array is the storage array you are removing.

  2. Detach the submirrors from the storage array that you are removing. Detach the submirrors to stop all I/O activity to the storage array.

    For more information, see your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation.

  3. Remove the references to the LUN(s) from any diskset or disk group.

    For more information, see your Solstice DiskSuite/Solaris Volume Manager or VERITAS Volume Manager documentation.

  4. Determine the resource groups and device groups that are running on Node B.


    # scstat
    
  5. Shut down Node A.

    For the procedure about how to shut down and power off a node, see your Sun Cluster system administration documentation.

  6. Is the storage array that you are removing the last storage array that is connected to Node A?

    • If yes, disconnect the fiber-optic cable between Node A and the FC hub/switch that is connected to this storage array. Afterward, disconnect the fiber-optic cable between the FC hub/switch and this storage array.

    • If no, proceed to Step 7.

    For the procedure about how to remove a fiber-optic cable, see the Sun StorEdge T3 and T3+ Array Configuration Guide.


    Note –

    If you are use your storage array in a SAN-configured cluster, you must keep two FC switches configured in parallel. This configuration maintains cluster availability. See SAN Solutions in a Sun Cluster Environment in Sun Cluster 3.0-3.1 Hardware Administration Manual for Solaris OS for more information.


  7. Do you want to remove the host adapter from Node A?

    • If yes, power off Node A.

    • If no, skip to Step 10.

  8. Remove the host adapter from Node A.

    For the procedure about how to remove host adapters, see the documentation that shipped with your nodes.

  9. Without enabling the node to boot, power on Node A.

    For more information, see your Sun Cluster system administration documentation.

  10. Boot Node A into cluster mode.

    For more information about how to boot nodes, see your Sun Cluster system administration documentation.

  11. Shut down Node B.

    For the procedure about how to shut down and power off a node, see your Sun Cluster system administration documentation.

  12. Is the storage array that you are removing the last storage array that is connected to the FC hub/switch.

    • If yes, disconnect the fiber-optic cable that connects this FC hub/switch and Node B.

    • If no, proceed to Step 13.

    For the procedure about how to remove a fiber-optic cable, see the Sun StorEdge T3 and T3+ Array Configuration Guide.


    Note –

    If you are use your storage array in a SAN-configured cluster, you must keep two FC switches configured in parallel. This configuration maintains cluster availability. See SAN Solutions in a Sun Cluster Environment in Sun Cluster 3.0-3.1 Hardware Administration Manual for Solaris OS for more information.


  13. Do you want to remove the host adapter from Node B?

    • If yes, power off Node B.

    • If no, skip to Step 16.

  14. Remove the host adapter fromNode B.

    For the procedure about how to remove host adapters, see the documentation that shipped with your nodes.

  15. Without enabling the node to boot, power on Node B

    For more information, see your Sun Cluster system administration documentation.

  16. Boot Node B into cluster mode.

    For more information about how to boot nodes, see your Sun Cluster system administration documentation.

  17. On all nodes, update the /devices and /dev entries.


    # devfsadm -C
    # scdidadm -C
    
  18. Return the resource groups and device groups that you identified in Step 4 to Node A and Node B..


    # scswitch -z -g resource-group -h nodename
    # scswitch -z -D device-group-name -h nodename
    

ProcedureHow to Remove a Partner Group

Use this procedure to permanently remove storage array partner groups and their submirrors from a running cluster. To remove a storage array in single-controller configuration, see How to Remove a Storage Array in a Single-Controller Configuration.


Note –

When you upgrade firmware on a storage device or on an enclosure, redefine the stripe size of a LUN, or perform other LUN operations, a device ID might change unexpectedly. When you perform a check of the device ID configuration by running the scdidadm -c command, the following error message appears on your console if the device ID changed unexpectedly.


device id for nodename:/dev/rdsk/cXtYdZsN does not match physical 
device's id for ddecimalnumber, device may have been replaced.

To fix device IDs that report this error, run the scdidadm -R command for each affected device.


This procedure defines Node A as the cluster node that you begin working with. Node B is another node in the cluster.


Caution – Caution –

During this procedure, you lose access to the data that resides on each storage array partner group that you are removing.


Steps
  1. If necessary, back up all database tables, data services, and volumes associated with each partner group that you are removing.

  2. If necessary, detach the submirrors from each storage array or partner group that you are removing. Detach the submirrors to stop all I/O activity to the storage array or partner group.

    For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.

  3. Remove references to each LUN. Each LUN belongs to the storage array or partner group that you are removing.

    For more information, see your Solstice DiskSuite or VERITAS Volume Manager documentation.

  4. Determine the resource groups and device groups that are running on all nodes.

    Record this information because you use this information in Step 19 of this procedure to return resource groups and device groups to these nodes.


    # scstat
    
  5. Shut down Node A.

    For the procedure about how to shut down and power off a node, see your Sun Cluster system administration documentation.

  6. Disconnect from both storage arrays the fiber-optic cables connecting to the FC switches, then the Ethernet cable(s).

  7. Is any storage array that you are removing the last storage array connected to an FC switch that is on Node A?

    • If no, skip to Step 11.

    • If yes, disconnect the fiber-optic cable between Node A and the FC switch that was connected to this storage array.

      For the procedure about how to remove a fiber-optic cable, see the Sun StorEdge T3 and T3+ Array Configuration Guide.


    Note –

    If you are using your storage arrays in a SAN-configured cluster, you must keep two FC switches configured in parallel. This configuration maintains cluster availability. See SAN Considerations for more information.


  8. Do you want to remove the host adapters from Node A?

    • If no, skip to Step 11.

    • If yes, power off Node A.

  9. Remove the host adapters from Node A.

    For the procedure about how to remove host adapters, see the documentation that shipped with your host adapter and nodes.

  10. Without enabling the node to boot, power on Node A

    For more information, see your Sun Cluster system administration documentation.

  11. Boot Node A into cluster mode.

    For more information on booting nodes, see your Sun Cluster system administration documentation.

  12. Shut down Node B.

    For the procedure about how to shut down and power off a node, see your Sun Cluster system administration documentation.

  13. Is any storage array that you are removing the last storage array connected to an FC switch that is on Node B?

    • If no, proceed to Step 14.

    • If yes, disconnect the fiber-optic cable that connects this FC switch to Node B.

      For the procedure about how to remove a fiber-optic cable, see the Sun StorEdge T3 and T3+ Array Configuration Guide.


    Note –

    If you are using your storage arrays in a SAN-configured cluster, you must keep two FC switches configured in parallel. This configuration maintains cluster availability. See SAN Considerations for more information.


  14. Do you want to remove the host adapters from Node B

    • If no, proceed to Step 17.

    • If yes, power off Node B.

  15. Remove the host adapters from Node B.

    For the procedure about how to remove host adapters, see the documentation that shipped with your nodes.

  16. Without enabling the node to boot, power on Node B

    For more information, see your Sun Cluster system administration documentation.

  17. Boot Node B into cluster mode.

    For more information about how to boot nodes, see your Sun Cluster system administration documentation.

  18. On all nodes, update the /devices and /dev entries.


    # devfsadm -C
    # scdidadm -C
    
  19. Return the resource groups and device groups that you identified in Step 4 to all nodes.


    # scswitch -z -g resource-group -h nodename
    # scswitch -z -D device-group-name -h 
    nodename