The following sections list the components in each of the physical servers. All servers of the same type are configured identically.
The following components are installed in the Sun Fire V210 Servers:
DVD-ROM, part number X7410A
Sun Crypto Accelerator, part number X7405A
The following components are installed in the Sun Fire V240 servers used for the management and administration stations:
DVD-ROM, part number X7410A
Sun Crypto Accelerator, part number X7405A
2 additional disks, part number XRA-SC1GB-73G10K
The PCI slot numbers on the back of Sun Fire V440 servers are numbered right to left 0 through 6. Components are installed in V440 systems as per the following table. HBA stands for host bus adapter that allows the server to attach to external storage.
Table 2–1 PCI Slot Components in Sun Fire V440 Servers
PCI Slot No |
Frequency |
Component |
Description |
---|---|---|---|
0 |
33MHz |
SG-XPCI2FC-QF2 |
PCI Dual HBA |
1 |
33MHz |
SG-XPCI2FC-QF2 |
PCI Dual HBA |
2 |
66MHz |
SG-XPCI2FC-QF2 |
PCI Dual HBA |
3 |
33MHz |
X3151A |
Gigaswift Ethernet |
4 |
66MHz |
SG-XPCI2FC-QF2 |
PCI Dual HBA |
5 |
66MHz |
X444A |
Quad Gigaswift Ethernet |
The following components are installed in the Sun Fire V880 server:
DVD-ROM, part number X6168A
Sun Crypto Accelerator, part number X7405A
6 Additional disks, part number X6756A
The Sun StorEdge 3510 arrays used for primary storage are grouped as set with 2 of JBOD and 1 Raid Controller unit. The following diagram shows how to connect the 3510 set.