Solaris Volume Manager Administration Guide

Optimizing for Random I/O and Sequential I/O

This section explains Solaris Volume Manager strategies for optimizing your particular configuration.

In general, if you do not know if sequential I/O or random I/O predominates on file systems you will be implementing on Solaris Volume Manager volumes, do not implement these performance tuning tips. These tips can degrade performance if they are improperly implemented.

The following optimization suggestions assume that you are optimizing a RAID 0 volume. In general, you would want to optimize a RAID 0 volume, then mirror that volume to provide both optimal performance and data redundancy.

Random I/O

If you have a random I/O environment, such as an environment used for databases and general-purpose file servers, you want all disk spindles to be approximately equal amounts of time servicing I/O requests.

For example, assume that you have 40 Gbytes of storage for a database application. If you stripe across four 10 Gbyte disk spindles, and if the I/O load is truly random and evenly dispersed across the entire range of the table space, then each of the four spindles will tend to be equally busy, which will generally improve performance.

The target for maximum random I/O performance on a disk is 35 percent or lower usage, as reported by the iostat command. Disk use in excess of 65 percent on a typical basis is a problem. Disk use in excess of 90 percent is a significant problem. The solution to having disk use values that are too high is to create a new RAID 0 volume with more disks (spindles).


Note –

Simply attaching additional disks to an existing volume will not improve performance. You must create a new volume with the ideal parameters to optimize performance.


The interlace size of the stripe doesn't matter because you just want to spread the data across all the disks. Any interlace value greater than the typical I/O request will do.

Sequential Access I/O

You can optimize the performance of your configuration to take advantage of a sequential I/O environment, such as DBMS servers that are dominated by full table scans and NFS servers in very data-intensive environments, by setting the interlace value low relative to the size of the typical I/O request.

For example, assume a typical I/O request size of 256 Kbyte and striping across 4 spindles. A good choice for stripe unit size in this example would be: 256 Kbyte / 4 = 64 Kbyte, or smaller.

This strategy ensures that the typical I/O request is spread across multiple disk spindles, thus increasing the sequential bandwidth.


Note –

Seek time and rotation time are practically zero in the sequential case. When you optimize sequential I/O, the internal transfer rate of a disk is most important.


In sequential applications, the typical I/O size is usually large (greater than 128 Kbytes, often greater than 1 Mbytes). Assume an application with a typical I/O request size of 256 Kbytes and assume striping across 4 disk spindles. 256 Kbytes / 4 = 64 Kbytes. So, a good choice for the interlace size would be 32 to 64 Kbyte.