NAME | SYNOPSIS | DESCRIPTION | FILES | SEE ALSO | DIAGNOSTICS
ide@unit-address
The uata host bus adapter driver is a nexus driver that supports the ide interface on SPARC platforms. The driver supports ultra DMA mode-4 (ATA66). The driver also attempts to set the disk and ATAPI CD-ROM drive to maximum supported speed for the device.
Currently, the uata driver supports IDE controllers CMD646U and Acer Southbridge M5229.
The uata driver supports two channels concurrently with two devices connected per channel. The devices are logically numbered from 0 to 3:
Master disk on primary channel
Slave disk on primary channel
Master disk on secondary channel
Slave disk on secondary channel
/kernel/drv/uata
prtconf(1M), driver.conf(4), attributes(5)
X3T10 ATA-4 specifications
In addition to being logged, the following messages may appear on the system console:
The driver could not obtain the interrupt cookie; the attach may fail.
Indicates a fatal problem; the drives are not ready to be programmed and features cannot be set. (During the driver initialization process, the driver must set the features for the drive, including dma and pio.)
Indicates a fatal problem with the drive; features could not be set.
Indicates a fatal problem with the drive; features could not be set.
Displayed at boot up time to indicate that the target <number> was identified, where <number> is a decimal value.
Residual number of bytes in data transfer and the I/O operation could not be finished completely.
Generally indicates a fatal condition; I/O operation could not be completed following reset of the channel.
A timeout occured because of <message> on device (target=<number>) on channel (chno =<number). Where <message> could be either early abort, early timeout, abort request, abort device, reset target or reset bus.
The drive did not respond before issuing the command <number> to the controller; command <number> will not be issued to the drive. (<number> is the hexadecimal opcode for the sleep or standby commands, which are issued when the drive transitions between power management states.)
Command <number> failed on the drive. (<number> is the hexadecimal opcode for the sleep or standby commands, which are issued when the drive transitions between power management states.)
Command <number> returned error. (<number> is the hexadecimal opcode for the sleep or standby commands, which are issued when the drive transitions between power management states.)
The disk will not transition to sleep state. (Indicates that the driver could not set the device to sleep mode while performing power management functions.)
The disk will not transition from sleep to active state.
An unsupported ata controller was found on the system and prints <ID>, device id and revision of the controller, where <ID> represents the hexidecimal vendor ID.
These messages are informational and indicate that a timeout occured for a I/O request. The uata driver recovers from these states automatically unless there is a fatal error.