Solaris Volume Manager Administration Guide

Chapter 15 RAID 5 Volumes (Tasks)

This chapter provides information about performing Solaris Volume Manager tasks that are associated with RAID 5 volumes. For information about the concepts involved in these tasks, see Chapter 14, RAID 5 Volumes (Overview).

RAID 5 Volumes (Task Map)

The following task map identifies the procedures needed to manage Solaris Volume Manager RAID 5 volumes.

Task 

Description 

Instructions 

Create RAID 5 volumes 

Use the Solaris Volume Manager GUI or the metainit command to create RAID 5 volumes.

How to Create a RAID 5 Volume

Check the status of RAID 5 volumes 

Use the Solaris Volume Manager GUI or the metastat command to check the status of RAID 5 volumes.

How to Check the Status of a RAID 5 Volume

Expand a RAID 5 volume 

Use the Solaris Volume Manager GUI or the metattach command to expand RAID 5 volumes.

How to Expand a RAID 5 Volume

Enable a slice in a RAID 5 volume 

Use the Solaris Volume Manager GUI or the metareplace command to enable slices in RAID 5 volumes.

How to Enable a Component in a RAID 5 Volume

Replace a slice in a RAID 5 volume 

Use the Solaris Volume Manager GUI or the metareplace command to replace slices in RAID 5 volumes.

How to Replace a Component in a RAID 5 Volume

Creating RAID 5 Volumes


Caution – Caution –

Do not create volumes larger than 1TB if you expect to run the Solaris software with a 32–bit kernel or if you expect to use a version of the Solaris OS prior to Solaris 9 4/03. See Overview of Large Volume Support in Solaris Volume Manager for more information about large volume support in Solaris Volume Manager.


ProcedureHow to Create a RAID 5 Volume

Steps
  1. Check Prerequisites for Creating Solaris Volume Manager Components and Background Information for Creating RAID 5 Volumes.

  2. To create the RAID 5 volume, use one of the following methods:

    • From the Enhanced Storage tool within the Solaris Management Console, open the Volumes node, then choose Action->Create Volume and follow the steps in the wizard. For more information, see the online help.

    • Use the following form of the metainit command:


      metainit name -r component component component
      
      • name is the name for the volume to create.

      • r specifies to create a RAID 5 volume.

      • component specifies a slice or soft partition to include in the RAID 5 volume.

      To specify an interlace value, add the -i interlace-value option. For more information, see the metainit(1M) man page.


Example 15–1 Creating a RAID 5 Volume of Three Slices


# metainit d45 -r c2t3d0s2 c3t0d0s2 c4t0d0s2
d45: RAID is setup

In this example, the RAID 5 volume d45 is created with the -r option from three slices. Because no interlace value is specified, d45 uses the default of 16 Kbytes. The system verifies that the RAID 5 volume has been set up, and begins initializing the volume.

You must wait for the initialization to finish before you can use the RAID 5 volume.


See Also

To prepare the newly created RAID 5 volume for a file system, see Chapter 16, Creating UFS, TMPFS, and LOFS File Systems (Tasks), in System Administration Guide: Devices and File Systems. An application, such as a database, that uses the raw volume must have its own way of recognizing the volume.

To associate a hot spare pool with a RAID 5 volume, see How to Associate a Hot Spare Pool With a Volume.

Maintaining RAID 5 Volumes

ProcedureHow to Check the Status of a RAID 5 Volume

When checking status of RAID 5 volumes, you need to check both the RAID 5 state and the slice state to fully understand the state of the volume and the possibility of data loss if the volumes are not in an Okay state. See Overview of Checking Status of RAID 5 Volumes for details.


Note –

RAID 5 volume initialization or resynchronization cannot be interrupted.


Step

    To check status on a RAID 5 volume, use one of the following methods:

    • From the Enhanced Storage tool within the Solaris Management Console, open the Volumes node and view the status of the volumes. Choose a volume, then choose Action->Properties to see more detailed information. For more information, see the online help.

    • Use the metastat command.

      For each slice in the RAID 5 volume, the metastat command shows the following:

      • “Device” (device name of the slice in the stripe)

      • “Start Block” on which the slice begins

      • “Dbase” to show if the slice contains a state database replica

      • “State” of the slice

      • “Hot Spare” to show the slice being used to hot spare a failed slice


Example 15–2 Viewing RAID 5 Volume Status

Here is sample RAID 5 volume output from the metastat command.


# metastat
d10: RAID
    State: Okay        
    Interlace: 32 blocks
    Size: 10080 blocks
Original device:
    Size: 10496 blocks
        Device              Start Block  Dbase State        Hot Spare
        c0t0d0s1                 330     No    Okay        
        c1t2d0s1                 330     No    Okay        
        c2t3d0s1                 330     No    Okay 

The metastat command output identifies the volume as a RAID 5 volume. For each slice in the RAID 5 volume, it shows the name of the slice in the stripe, the block on which the slice begins, an indicator that none of these slices contain a state database replica, that all the slices are okay, and that none of the slices are hot spare replacements for a failed slice.


ProcedureHow to Expand a RAID 5 Volume

In general, attaching components is a short-term solution to a RAID 5 volume that is running out of space. For performance reasons, it is best to have a “pure” RAID 5 volume. If you must expand an existing RAID 5 volume to gain extra storage space, use this procedure.


Caution – Caution –

Do not create volumes larger than 1TB if you expect to run the Solaris software with a 32–bit kernel or if you expect to use a version of the Solaris OS prior to Solaris 9 4/03. See Overview of Large Volume Support in Solaris Volume Manager for more information about large volume support in Solaris Volume Manager.


Steps
  1. Make sure that you have a current backup of all data and that you have root access.

  2. Read Background Information for Creating RAID 5 Volumes.

  3. To attach additional components to a RAID 5 volume, use one of the following methods:

    • From the Enhanced Storage tool within the Solaris Management Console, open the Volumes node, then open the RAID 5 volume. Choose the Components pane, then choose Attach Component and follow the instructions. For more information, see the online help.

    • Use the following form of the metattach command:


      metattach volume-name name-of-component-to-add
      
      • volume-name is the name for the volume to expand.

      • name-of-component-to-add specifies the name of the component to attach to the RAID 5 volume.

      See the metattach(1M) man page for more information.


Example 15–3 Adding a Component to a RAID 5 Volume


# metattach d2 c2t1d0s2
d2: column is attached

This example shows the addition of slice c2t1d0s2 to an existing RAID 5 volume named d2.


See Also

For a UFS, run the growfs command on the RAID 5 volume. See Volume and Disk Space Expansion.

An application, such as a database, that uses the raw volume must have its own way of growing the added space.

ProcedureHow to Enable a Component in a RAID 5 Volume


Note –

If a disk drive is defective, you can replace it with another available disk (and its slices) on the system as documented in How to Replace a Component in a RAID 5 Volume. Alternatively, you can repair/replace the disk, label it, and run the metareplace command with the -e option.


Steps
  1. Make sure that you have a current backup of all data and that you have root access.

  2. To enable a failed component in a RAID 5 volume, use one of the following methods:

    • From the Enhanced Storage tool within the Solaris Management Console, open the Volumes node, then open the RAID 5 volume. Choose the Components pane, then choose the failed component. Click Enable Component and follow the instructions. For more information, see the online help.

    • Use the following form of the metareplace command:


      metareplace -e volume-name component-name
      
      • -e specifies to replace the failed component with a component at the same location (perhaps after physically replacing a disk).

      • volume-name is the name of the volume with a failed component.

      • component-name specifies the name of the component to replace.

      metareplace automatically starts resynchronizing the new component with the rest of the RAID 5 volume.


Example 15–4 Enabling a Component in a RAID 5 Volume


# metareplace -e d20 c2t0d0s2

In this example, the RAID 5 volume d20 has a slice, c2t0d0s2, which had a soft error. The metareplace command with the -e option enables the slice.


ProcedureHow to Replace a Component in a RAID 5 Volume

This task replaces a failed slice of a RAID 5 volume in which only one slice has failed.


Caution – Caution –

Replacing a failed slice when multiple slices are in error might cause data to be fabricated. The integrity of the data in this instance would be questionable.


You can use the metareplace command on non-failed devices to change a disk slice or other component. This procedure can be useful for tuning the performance of RAID 5 volumes.

Steps
  1. Make sure that you have a current backup of all data and that you have root access.

  2. Use one of the following methods to determine which slice of the RAID 5 volume needs to be replaced:

    • From the Enhanced Storage tool within the Solaris Management Console, open the Volumes node, then open the RAID 5 volume. Choose the Components pane, then view the status of the individual components. For more information, see the online help.

    • Use the metastat command.

    Look for the keyword “Maintenance” to identify the failed slice.

  3. Use one of the following methods to replace the failed slice with another slice:

    • From the Enhanced Storage tool within the Solaris Management Console, open the Volumes node, then open the RAID 5 volume. Choose the Components pane, then choose the failed component. Click Replace Component and follow the instructions. For more information, see the online help.

    • Use the following form of the metareplace command:


      metareplace volume-name failed-component new-component
      
      • volume-name is the name of the volume with a failed component.

      • failed-component specifies the name of the component to replace.

      • new-component specifies the name of the component to add to the volume in place of the failed component.

      See the metareplace(1M) man page for more information.

  4. To verify the status of the replacement slice, use one of the methods described in Step 2.

    The state of the replaced slice should be “Resyncing” or “Okay”.


Example 15–5 Replacing a RAID 5 Component


# metastat d1
d1: RAID
State: Needs Maintenance
    Invoke: metareplace d1 c0t14d0s6 <new device>
    Interlace: 32 blocks
    Size: 8087040 blocks
Original device:
    Size: 8087520 blocks
	Device              Start Block  Dbase State        Hot Spare
	c0t9d0s6                 330     No    Okay        
	c0t13d0s6                330     No    Okay        
	c0t10d0s6                330     No    Okay        
	c0t11d0s6                330     No    Okay        
	c0t12d0s6                330     No    Okay        
	c0t14d0s6                330     No    Maintenance
 
# metareplace d1 c0t14d0s6 c0t4d0s6
d1: device c0t14d0s6 is replaced with c0t4d0s6
# metastat d1
d1: RAID
    State: Resyncing
    Resync in progress: 98% done
    Interlace: 32 blocks
    Size: 8087040 blocks
Original device:
    Size: 8087520 blocks
	Device              Start Block  Dbase State        Hot Spare
	c0t9d0s6                 330     No    Okay        
	c0t13d0s6                330     No    Okay        
	c0t10d0s6                330     No    Okay        
	c0t11d0s6                330     No    Okay        
	c0t12d0s6                330     No    Okay
	c0t4d0s6                 330     No    Resyncing

In this example, the metastat command displays the action to take to recover from the failed slice in the d1 RAID 5 volume. After locating an available slice, the metareplace command is run, specifying the failed slice first, then the replacement slice. (If no other slices are available, run the metareplace command with the -e option to attempt to recover from possible soft errors by resynchronizing the failed device.) If multiple errors exist, the slice in the “Maintenance” state must first be replaced or enabled. Then the slice in the “Last Erred” state can be repaired. After the metareplace command, the metastat command monitors the progress of the resynchronization. During the replacement, the state of the volume and the new slice will is “Resyncing.” You can continue to use the volume while it is in this state.