You can also accomplish this procedure by using the Sun Cluster Manager GUI. See the Sun Cluster Manager online help for more information.
This procedure provides the long forms of the Sun Cluster commands. Most commands also have short forms. Except for the long and short forms of the command names, the commands are identical. For a list of the commands and their short forms, see Appendix A, Sun Cluster Object-Oriented Commands.
Users other than superuser require solaris.cluster.read RBAC authorization to use the status subcommand.
View the cluster configuration.
% cluster show |
To display more information by using the cluster command, use the verbose options. See the cluster(1CL) man page for details.
The following example lists the cluster configuration.
% cluster show |
=== Cluster ===
Cluster Name: cluster-1
installmode: disabled
heartbeat_timeout: 10000
heartbeat_quantum: 1000
private_netaddr: 172.16.0.0
private_netmask: 255.255.248.0
max_nodes: 64
max_privatenets: 10
global_fencing: Unknown
Node List: phys-schost-1
Node Zones: phys_schost-2:za
=== Host Access Control ===
Cluster name: clustser-1
Allowed hosts: phys-schost-1, phys-schost-2:za
Authentication Protocol: sys
=== Cluster Nodes ===
Node Name: phys-schost-1
Node ID: 1
Type: cluster
Enabled: yes
privatehostname: clusternode1-priv
reboot_on_path_failure: disabled
globalzoneshares: 3
defaultpsetmin: 1
quorum_vote: 1
quorum_defaultvote: 1
quorum_resv_key: 0x43CB1E1800000001
Transport Adapter List: qfe3, hme0
--- Transport Adapters for phys-schost-1 ---
Transport Adapter: qfe3
Adapter State: Enabled
Adapter Transport Type: dlpi
Adapter Property(device_name): qfe
Adapter Property(device_instance): 3
Adapter Property(lazy_free): 1
Adapter Property(dlpi_heartbeat_timeout): 10000
Adapter Property(dlpi_heartbeat_quantum): 1000
Adapter Property(nw_bandwidth): 80
Adapter Property(bandwidth): 10
Adapter Property(ip_address): 172.16.1.1
Adapter Property(netmask): 255.255.255.128
Adapter Port Names: 0
Adapter Port State(0): Enabled
Transport Adapter: hme0
Adapter State: Enabled
Adapter Transport Type: dlpi
Adapter Property(device_name): hme
Adapter Property(device_instance): 0
Adapter Property(lazy_free): 0
Adapter Property(dlpi_heartbeat_timeout): 10000
Adapter Property(dlpi_heartbeat_quantum): 1000
Adapter Property(nw_bandwidth): 80
Adapter Property(bandwidth): 10
Adapter Property(ip_address): 172.16.0.129
Adapter Property(netmask): 255.255.255.128
Adapter Port Names: 0
Adapter Port State(0): Enabled
--- SNMP MIB Configuration on phys-schost-1 ---
SNMP MIB Name: Event
State: Disabled
Protocol: SNMPv2
--- SNMP Host Configuration on phys-schost-1 ---
--- SNMP User Configuration on phys-schost-1 ---
SNMP User Name: foo
Authentication Protocol: MD5
Default User: No
Node Name: phys-schost-2:za
Node ID: 2
Type: cluster
Enabled: yes
privatehostname: clusternode2-priv
reboot_on_path_failure: disabled
globalzoneshares: 1
defaultpsetmin: 2
quorum_vote: 1
quorum_defaultvote: 1
quorum_resv_key: 0x43CB1E1800000002
Transport Adapter List: hme0, qfe3
--- Transport Adapters for phys-schost-2 ---
Transport Adapter: hme0
Adapter State: Enabled
Adapter Transport Type: dlpi
Adapter Property(device_name): hme
Adapter Property(device_instance): 0
Adapter Property(lazy_free): 0
Adapter Property(dlpi_heartbeat_timeout): 10000
Adapter Property(dlpi_heartbeat_quantum): 1000
Adapter Property(nw_bandwidth): 80
Adapter Property(bandwidth): 10
Adapter Property(ip_address): 172.16.0.130
Adapter Property(netmask): 255.255.255.128
Adapter Port Names: 0
Adapter Port State(0): Enabled
Transport Adapter: qfe3
Adapter State: Enabled
Adapter Transport Type: dlpi
Adapter Property(device_name): qfe
Adapter Property(device_instance): 3
Adapter Property(lazy_free): 1
Adapter Property(dlpi_heartbeat_timeout): 10000
Adapter Property(dlpi_heartbeat_quantum): 1000
Adapter Property(nw_bandwidth): 80
Adapter Property(bandwidth): 10
Adapter Property(ip_address): 172.16.1.2
Adapter Property(netmask): 255.255.255.128
Adapter Port Names: 0
Adapter Port State(0): Enabled
--- SNMP MIB Configuration on phys-schost-2 ---
SNMP MIB Name: Event
State: Disabled
Protocol: SNMPv2
--- SNMP Host Configuration on phys-schost-2 ---
--- SNMP User Configuration on phys-schost-2 ---
=== Transport Cables ===
Transport Cable: phys-schost-1:qfe3,switch2@1
Cable Endpoint1: phys-schost-1:qfe3
Cable Endpoint2: switch2@1
Cable State: Enabled
Transport Cable: phys-schost-1:hme0,switch1@1
Cable Endpoint1: phys-schost-1:hme0
Cable Endpoint2: switch1@1
Cable State: Enabled
Transport Cable: phys-schost-2:hme0,switch1@2
Cable Endpoint1: phys-schost-2:hme0
Cable Endpoint2: switch1@2
Cable State: Enabled
Transport Cable: phys-schost-2:qfe3,switch2@2
Cable Endpoint1: phys-schost-2:qfe3
Cable Endpoint2: switch2@2
Cable State: Enabled
=== Transport Switches ===
Transport Switch: switch2
Switch State: Enabled
Switch Type: switch
Switch Port Names: 1 2
Switch Port State(1): Enabled
Switch Port State(2): Enabled
Transport Switch: switch1
Switch State: Enabled
Switch Type: switch
Switch Port Names: 1 2
Switch Port State(1): Enabled
Switch Port State(2): Enabled
=== Quorum Devices ===
Quorum Device Name: d3
Enabled: yes
Votes: 1
Global Name: /dev/did/rdsk/d3s2
Type: scsi
Access Mode: scsi2
Hosts (enabled): phys-schost-1, phys-schost-2
Quorum Device Name: qs1
Enabled: yes
Votes: 1
Global Name: qs1
Type: quorum_server
Hosts (enabled): phys-schost-1, phys-schost-2
Quorum Server Host: 10.11.114.83
Port: 9000
=== Device Groups ===
Device Group Name: testdg3
Type: SVM
failback: no
Node List: phys-schost-1, phys-schost-2
preferenced: yes
numsecondaries: 1
diskset name: testdg3
=== Registered Resource Types ===
Resource Type: SUNW.LogicalHostname:2
RT_description: Logical Hostname Resource Type
RT_version: 2
API_version: 2
RT_basedir: /usr/cluster/lib/rgm/rt/hafoip
Single_instance: False
Proxy: False
Init_nodes: All potential masters
Installed_nodes: <All>
Failover: True
Pkglist: SUNWscu
RT_system: True
Resource Type: SUNW.SharedAddress:2
RT_description: HA Shared Address Resource Type
RT_version: 2
API_version: 2
RT_basedir: /usr/cluster/lib/rgm/rt/hascip
Single_instance: False
Proxy: False
Init_nodes: <Unknown>
Installed_nodes: <All>
Failover: True
Pkglist: SUNWscu
RT_system: True
Resource Type: SUNW.HAStoragePlus:4
RT_description: HA Storage Plus
RT_version: 4
API_version: 2
RT_basedir: /usr/cluster/lib/rgm/rt/hastorageplus
Single_instance: False
Proxy: False
Init_nodes: All potential masters
Installed_nodes: <All>
Failover: False
Pkglist: SUNWscu
RT_system: False
Resource Type: SUNW.haderby
RT_description: haderby server for Sun Cluster
RT_version: 1
API_version: 7
RT_basedir: /usr/cluster/lib/rgm/rt/haderby
Single_instance: False
Proxy: False
Init_nodes: All potential masters
Installed_nodes: <All>
Failover: False
Pkglist: SUNWscderby
RT_system: False
Resource Type: SUNW.sctelemetry
RT_description: sctelemetry service for Sun Cluster
RT_version: 1
API_version: 7
RT_basedir: /usr/cluster/lib/rgm/rt/sctelemetry
Single_instance: True
Proxy: False
Init_nodes: All potential masters
Installed_nodes: <All>
Failover: False
Pkglist: SUNWsctelemetry
RT_system: False
=== Resource Groups and Resources ===
Resource Group: HA_RG
RG_description: <Null>
RG_mode: Failover
RG_state: Managed
Failback: False
Nodelist: phys-schost-1 phys-schost-2
--- Resources for Group HA_RG ---
Resource: HA_R
Type: SUNW.HAStoragePlus:4
Type_version: 4
Group: HA_RG
R_description:
Resource_project_name: SCSLM_HA_RG
Enabled{phys-schost-1}: True
Enabled{phys-schost-2}: True
Monitored{phys-schost-1}: True
Monitored{phys-schost-2}: True
Resource Group: cl-db-rg
RG_description: <Null>
RG_mode: Failover
RG_state: Managed
Failback: False
Nodelist: phys-schost-1 phys-schost-2
--- Resources for Group cl-db-rg ---
Resource: cl-db-rs
Type: SUNW.haderby
Type_version: 1
Group: cl-db-rg
R_description:
Resource_project_name: default
Enabled{phys-schost-1}: True
Enabled{phys-schost-2}: True
Monitored{phys-schost-1}: True
Monitored{phys-schost-2}: True
Resource Group: cl-tlmtry-rg
RG_description: <Null>
RG_mode: Scalable
RG_state: Managed
Failback: False
Nodelist: phys-schost-1 phys-schost-2
--- Resources for Group cl-tlmtry-rg ---
Resource: cl-tlmtry-rs
Type: SUNW.sctelemetry
Type_version: 1
Group: cl-tlmtry-rg
R_description:
Resource_project_name: default
Enabled{phys-schost-1}: True
Enabled{phys-schost-2}: True
Monitored{phys-schost-1}: True
Monitored{phys-schost-2}: True
=== DID Device Instances ===
DID Device Name: /dev/did/rdsk/d1
Full Device Path: phys-schost-1:/dev/rdsk/c0t2d0
Replication: none
default_fencing: global
DID Device Name: /dev/did/rdsk/d2
Full Device Path: phys-schost-1:/dev/rdsk/c1t0d0
Replication: none
default_fencing: global
DID Device Name: /dev/did/rdsk/d3
Full Device Path: phys-schost-2:/dev/rdsk/c2t1d0
Full Device Path: phys-schost-1:/dev/rdsk/c2t1d0
Replication: none
default_fencing: global
DID Device Name: /dev/did/rdsk/d4
Full Device Path: phys-schost-2:/dev/rdsk/c2t2d0
Full Device Path: phys-schost-1:/dev/rdsk/c2t2d0
Replication: none
default_fencing: global
DID Device Name: /dev/did/rdsk/d5
Full Device Path: phys-schost-2:/dev/rdsk/c0t2d0
Replication: none
default_fencing: global
DID Device Name: /dev/did/rdsk/d6
Full Device Path: phys-schost-2:/dev/rdsk/c1t0d0
Replication: none
default_fencing: global
=== NAS Devices ===
Nas Device: nas_filer1
Type: netapp
User ID: root
Nas Device: nas2
Type: netapp
User ID: llai
|