The following restrictions apply to hardware in all Sun Cluster Geographic Edition configurations.
Multihost tape, CD-ROM, and DVD-ROM are not supported.
Alternate pathing (AP) is not supported.
Storage devices with more than a single path from a given cluster node to the enclosure are not supported except for the following storage devices:
Sun StorEdgeTM A3500, for which two paths are supported to each of two nodes.
Devices using Sun StorEdge Traffic Manager, formerly Sun StorEdge Traffic Manager.
EMC storage devices that use EMC PowerPath software.
Sun StorEdge 9900 storage devices that use HDLM.
If you are using a Sun EnterpriseTM 420R server with a PCI card in slot J4701, the motherboard must be at least dash-level 15 (at least 501–5168–15). To find the motherboard part number and revision level, look at the edge of the board closest to PCI slot 1.
System panics have been observed in clusters when UDWIS I/O cards are used in slot 0 of a board in a Sun Enterprise 10000 server; do not install UDWIS I/O cards in slot 0 of this server.
Sun VTSTM software is not supported.