Sun Cluster 3.2 Release Notes for Solaris OS

ProcedureHow to Apply the Sun Cluster 3.2 Core Patch

  1. Install the patch using the usual rebooting patch procedure for a core patch.

  2. Verify that the patch has been installed correctly on all nodes and is functioning properly.

  3. Register the new version of resource types SUNW.HAStoragePlus, SUNW.ScalDeviceGroup, and SUNW.ScalMountPoint that are being updated in this patch. Perform resource type upgrade on any existing resources of these types to the new versions.

    For information about registering a resource type, see Registering a Resource Type in Sun Cluster Data Services Planning and Administration Guide for Solaris OS in Sun Cluster Data Services Planning and Administration Guide for Solaris OS.


    Caution – Caution –

    If the Sun Cluster 3.2 core patch is removed, any resources that were upgraded in step 3 must be downgraded to the earlier resource type versions. The procedure for downgrading will require planned downtime of these services. Therefore, do not perform step 3 until you are ready to commit the Sun Cluster 3.2 core patch permanently to your cluster.