Item
|
Description
|
Host Interface
|
Three, 3 G SAS ports on each SIM module
|
Hard Disk Interface
|
SAS Disk Drives: 73 GB, 146 GB, and 300 GB at 15 K RPM
|
|
SATA II Disk Drives: 250 GB, 500 GB, and 750 GB at 7.2 K RPM
|
Drive Slots
|
J4200: A maximum of 12 disks per system with a two-drive minimum; interconnects up to four systems and 48 disk drives
|
|
J4400: A maximum of 24 disks per system with a two-drive minimum; interconnects up to four systems and 96 disk drives
|
|
3.5-inch form factor, 1.0-inch height
|
Redundant, Hot Swappable Components
|
Two SIM boards
|
|
Two power supply modules
|
|
Two fan modules (J4200 only)
|
|
Up to 12 (J4200) or 24 (J4400) SAS or SATA II disks
|
System Form Factor
|
Internal bays for up to 12 disks (J4200) or 24 disks (J4400)
|
|
Rack mount in a 19-inch cabinet
|
Dimensions
|
J4200 - 2 Rack Units: The chassis is 17.51 in. (445 mm) wide X 3.44 in. (87.4 mm) high X 24.05 in. (611 mm) deep (not including cables)
J4400 - 4 Rack Units: The chassis is 17.51 in. (445 mm) wide X 6.88 in. (174.8 mm) high X 23.38 in. (594 mm) deep (not including cables)
|
Management Features
|
Online software and firmware upgrades
|
|
Status indicators for SIM boards, disks, power supplies, and fan modules
|
AC Power
Maximum Operating Current
Maximum Operating Current
|
J4200: 9 A maximum operating (100 VAC to 127 VAC range), 47 to 63 Hz
4.5 A maximum operating (200 VAC to 240 VAC range, 47 to 63 Hz
1.51 A maximum operating @ 240 VAC (198 VAC to 264 VAC range), 50 to 60 Hz
J4400: 10 A maximum operating (100 VAC to 127 VAC range), 47 to 63 Hz
2.47 A maximum operating @ 240 VAC (198 VAC to 264 VAC range), 50 to 60 Hz
|
Operating Environment
|
Heat output J4200: 352.8 Watts (1204 BTU/hour)
|
|
Heat output J4400: 662 Watts (2123 BTU/hour)
|
|
Temperature: 35˚ F to 95˚ F (0˚ C to 35˚ C) maximum
|
|
Humidity: 20% to 80% (noncondensing) maximum
|
|
Altitude: 0 to 9,843 feet (3,000 meters)
|
|
Shock: 31-G +/-5%, with pulse duration of 2.6 ms or less half-sine, bottom side tested only
|
|
Vibration: 0.25 G (peak), 3 to 200 Hz sweep @ 1/2 octave per minute, bottom side tested only
|
ElectroMagnetic Compatibility (EMC) Standards
|
FCC 47CFR15 Subpart B Class A (USA)
|
|
ICES-003 Class A (Canada)
|
|
CE Mark including EN55022 Class A, EN55024, EN61000-3-2, and EN61000-3-3 (Europe)
|
|
VCCI-03 Class A (Japan)
|
|
CCC Class A (China)
|
|
BSMI CNS13438 Class A (Taiwan)
|
|
C-Tick Mark (Australia and New Zealand)
|
Safety Standards
|
UL/CUL: U.S. with Canada / UL60950-1
|
|
TUV Sud: Europe / EN60950-1
|
|
CB (by TUV): IEC60950-1
|
|
BSMI: Taiwan / CNS14336
|
|
CCC: China
|
Sun Supported Racks
|
Sun Rack 900/1000 cabinet
|
|
Sun StorEdge Expansion cabinet
|
|
Sun Fire Expansion Cabinet
|
|