Dimension |
Measurement |
Length |
5.776 in. (146.71 mm) |
Width |
3.3 in. (83.82 mm) |
Weight |
4.3 oz. (125g) |
Specification |
Measurement |
Maximum Power Dissipation |
14 Watts |
Maximum Power Consumption |
2.8 Amps @ 5V |
Voltage Tolerance |
5V +/- 5% |
Ripple |
Maximum 100 mV |
Operational Current |
5V, 2.0 Amps |
Condition |
Operating Specification |
Storage Specification |
---|---|---|
Temperature |
0 to 70C (+32 to +131F) |
-40 to 75C (-40 to +167F) |
Relative Humidity |
5 to 85% non-condensing |
0 to 95% non-condensing |
|
(40C, wet bulb temperature) |
40C /hour |
Altitude |
-1000 to +15,000 ft. |
-1000 to +50,000 ft. |
Shock |
5g, 1/2 sine wave, 11 msec |
30g, 1/2 sine wave, 11 msec |
Vibration, pk to pk displacement |
0.005 in. max. (5 to 32 Hz) |
0.1 in. max (5 to 17 Hz) |
Vibration, peak acceleration |
0.25g (5 to 500 Hz) |
1.0g (5 to 500 Hz) |
|
(Sweep Rate = 1 octave/min.) |
(Sweep Rate = 1 octave/min.) |
Specification |
Performance |
Maximum Ethernet Transfer Rate |
10/100 Mbps per channel |
Host Interface
|
IEEE 1496 SBus master interface with support for 64-bit mode accesses, and an SBus slave interface, at 32-bit mode only. |
Network Interface |
100BASE-TX using Category 5 (data-grade) cable; 10BASE-T using Category 3 (voice-grade) cable or better Single UTP RJ-45 for both 10 and 100 Mbps per channel |
Ethernet Version |
Conforms to IEEE 802.3u |
SBus Burst Sizes |
16/32/64 bytes |
SBus Parity |
Yes |
SBus Clock |
25 MHz max., 16.67 MHz min. |
Max SBus Burst Transfer Rate |
67 (25 MHz), 44.89 (16.67 MHz) Mbytes/sec1 |
Steady State SBus Transfer Rate |
50 Mbytes/sec2 |
Max Ethernet Transfer Rate |
12.5 Mbytes/sec per channel |
SBus Data/Address Lines |
D (31:0)/PA (18:0) |
SBus Modes |
Master/Slave |
Capacitance per SBus Signal Line |
<= 20 pF |
SBus Version |
Conforms to IEEE 1496 |
1 Assumes 64 Byte Burst and 0 SBus Latency |
|
2 4 Channels Running At Max Ethernet Speed |