You can use the ndd utility in two modes:
Non-interactive
Interactive
In non-interactive mode, you invoke the utility to execute a specific command. Once the command is executed, you exit the utility. In interactive mode, you can use the utility to get or set more than one parameter value. (Refer to the ndd (1M) man page for more information.)
This section describes how to modify and to display parameter values.
To modify a parameter value, use the -set option.
If you invoke the ndd utility with the -set option, the utility passes value, which must be specified down to the named /dev/qfe driver instance, and assigns it to the parameter:
# ndd -set /dev/qfe parameter value
To display the value of a parameter, specify the parameter name (and omit the value).
When you omit the -set option, a query operation is assumed and the utility queries the named driver instance, retrieves the value associated with the specified parameter, and prints it:
# ndd /dev/qfe parameter
To modify a parameter value in interactive mode, specify ndd /dev/qfe, as shown below.
The ndd utility then prompts you for the name of the parameter:
# ndd /dev/qfe name to get/set? (Enter the parameter name or ? to view all parameters)
After entering the parameter name, the ndd utility prompts you for the parameter value (see Table C-1 through Table C-8).
To list all the parameters supported by the qfe driver, type ndd /dev/qfe \?.
(See Table C-1 through Table C-8 for parameter descriptions.)
# ndd /dev/qfe \? ? (read only) transceiver_inuse (read only) link_status (read only) link_speed (read only) link_mode (read only) ipg1 (read and write) ipg2 (read and write) use_int_xcvr (read and write) pace_size (read and write) adv_autoneg_cap (read and write) adv_100fdx_cap (read and write) adv_100hdx_cap (read and write) adv_10fdx_cap (read and write) adv_10hdx_cap (read and write) autoneg_cap (read only) 100fdx_cap (read only) 100hdx_cap (read only) 10fdx_cap (read only) 10hdx_cap (read only) lp_autoneg_cap (read only) lp_100fdx_cap (read only) lp_100hdx_cap (read only) lp_10fdx_cap (read only) lp_10hdx_cap (read only) instance (read and write) lance_mode (read and write) ipg0 (read and write) #