To reach the dialog box below, right-click on the test name in the System Map and select Test Parameter Options. If you do not see this test in the System Map, you might need to expand the collapsed groups, or your system may not include the device appropriate to this test. Refer to the SunVTS User's Guide for more details.
Option |
Description |
---|---|
Enet_Test |
Enables or disables Ethernet testing. |
Edata_Pattern_Type |
Selects the type of data pattern for Enet_Test: Sequential, Random, or both. |
Num_Packets |
Specifies the number of data packets to be sent in one test loop. |
Target_IP_Addr |
Specifies the IP address of a host to use for the ping test. |
Etest_Type |
Selects any or all internal, external, Phy (ethernet transceiver), or ping tests. |
Serial_Test |
Enables or disables serial_test. |
Loopback_Type |
Selects internal loopback, external loopback, or both. |
Sdata_Pattern_Type |
Selects the type of data pattern for serial_test: Sequential, Random, or both. |
STest_Type |
Selects ports to be tested: c, d, u, or v. |
TTYU_Baud |
Selects the alarm card's COM1 port baud rate. |
TTYV_Baud |
Selects the alarm card's COM2 port baud rate. |
PC_Card_Test |
Enables or disables PC card (PCMCIA) testing. |
PC_Card_Type |
Specifies the card type for the PC Card: modem or serial i/o. |
Flash_Test |
Enables or disables the flash checksum test. |
SEEPROM_test |
Enables or disables the SEEPROM checksum test. |
TOD_test |
Enables or disables the TOD checksum test. |
ALARMPORT |
Enables or disables the alarmport test. |
ALARMNUM |
Selects any or all alarm ports to be tested: 0, 1, 2, 3. |
ALARM0ON |
Turns on, turns off, or toggles (on then off) alarm port 0. |
ALARM1ON |
Turns on, turns off, or toggles (on then off) alarm port 1. |
ALARM2ON |
Turns on, turns off, or toggles (on then off) alarm port 2. |
ALARM3ON |
Turns on, turns off, or toggles (on then off) alarm port 3. |
The alarmport test requires a visual check using an LED box.
The loopback tests use the following external loopbacks:
Ethernet loopback test--standard RJ-45 connector. Connect pin 1 to pin 3, and pin 2 to pin 6.
Serial loopback test for Netra ct 800--DB-9 connector. Connect pin 2 to pin 3, pins 4 and 6 to pin 1, and pin 7 to pin 8.
Serial loopback test for Netra ct 400--RJ-45. Connect pin 6 to pin 3, pin 1 to pin 8, and pin 2 to pin 7.