Enclosure Services Functional test
(general description)
|
Certain control operations are performed on devices in the enclosure through the SES device and verified that the operation was performed successful. This functional test involves the following steps:
-
Perform control operation.
-
Verify control operation was successful.
-
Restore state to what it was before 1.
-
Verify restore operation was successful.
The test will fail if any one of the above steps fails.
This test targets the disks and the fans in the enclosure.
|
Enclosure Services Functional test
(detailed Disk test description)
|
-
Control Operation--Each port of the disk is toggled from its original state. A port that was originally connected will be bypassed and vice-versa.
-
Verify Control Operation--This is done in two ways. First, the new status of the disk ports is verified by reading the status through the SES device. The test will fail if the status read back does not reflect the change. Next, disk access is attempted through the port that was originally connected but has now been bypassed. The test will fail if the access attempt is successful.
-
Restore State--The port states are restored to what they were before the Control Operation.
-
Verify Restore Operation--This is done in two ways. First the status of the disk ports is verified by reading the status through the SES device. The test will fail if the status read back does not reflect the change. Next, disk access is attempted through the port that have been reconnected. The test will fail if the access attempt is unsuccessful.
|