SunVTS 5.0 Test Reference Manual

saiptest Options

To reach the dialog box below, right-click on the test name in the System Map and select Test Parameter Options. If you do not see this test in the System Map, you might need to expand the collapsed groups, or your system may not include the device appropriate to this test. Refer to the SunVTS User's Guide for more details.

Figure 46-1 saiptest Test Parameter Options Dialog Box

Graphic

The Configuration section of the Options dialog box displays the asynchronous serial ports available for the SAI board. Table 4-1 shows the available ports.

Table 46-1 saiptest Asynchronous Serial Ports

Board Number 

Board Device 

Serial Ports 

saip0 

term/a000-a007 

saip1 

term/b000-b007 

saip2 

term/c000-c007 

saip3 

term/d000-d007 

saip4 

term/e000-e007 

saip5 

term/f000-f007 

saip6 

term/g000-g007 

saip7 

term/h000-h007 

saip8 

term/i000-i007 

saip9 

term/j000-j007 

10 

saip10 

term/k000-k007 

11 

saip11 

term/l000-l007 

12 

saip12 

term/m000-m007 

13 

saip 13 

term/n000-n007 

14 

saip 14 

term/o000-o007 

15 

saip 15 

term/p00-p007 

Table 46-2 saiptest Options

saiptest Option

Description 

Internal Test 

Performs internal loopback testing on the SAI card(s) installed in PCI slots. You do not need to attach anything to the card(s) to perform this test. 

25-pin Loopback 

Provides full-duplex transmission and full-modem loopback testing of the serial port selected in the Serial Port section of the option menu. Attach the 25-pin loopback plug to the serial port on the serial asynchronous interface patch panel that is being tested. This test cannot be run concurrently with the Echo-TTY option enabled. 

Echo-TTY 

Checks the proper operation of the serial port selected in the Serial Port selection of the option menu by echoing characters typed on a TTY terminal keyboard to the TTY terminal screen. The characters you type on your TTY keyboard display on the TTY screen. 

 

Note: A TTY connection to the serial asynchronous interface serial port requires corresponding character size se up. For example, if a TTY attachment is running with 8-bit character size, then the Char Size saiptest option should be set to 8- bits. If you do not type any characters within two minutes, this test times-out.

Baud Rate 

Specifies the baud rate. Choose 110, 300, 600, 1200, 2400, 4800, 9600, 19200, or 38400 baud. 

Note: The baud rate of 38400 can only be used if the Internal test is disabled and you are testing one port at a time. 

Char Size 

Specifies the character length. Choose 5, 6, 7, or 8 characters. 

Stop Bit 

Specifies the number of stop bits. Choose 1 or 2 bits. 

Parity 

Specifies the selectable parity. Choose none, odd, or even. 

Flow Control 

Specifies the selectable flow control. Choose XOnOff, 

rtscts, or both. 

Data Type 

Specifies the selectable data type pattern. Choose 0x55555555 

(0x55), 0xaaaaaaaa (0xaa), or random. 

Serial Port 

Specifies the serial port to be tested. The available ports 

are listed in the Configurations section at the top of the saiptest options menu.

Timeout 