Parallel Port Printer Test (pptest)
|
The pptest exercises the
parallel port devices. The test supports Sbus parallel port and IEEE 1286 complaint parallel port.
The parallel port device is an exclusive use device. Only
one application can interface with it at a time.
This test is not scalable.
Hardware and Software Requirements
The SBus printer card or IEEE 1284 compliant parallel port
device and device drivers must be installed to run pptest. To run the optional printer subtest, a printer
must be attached to the printer port, and be powered-up.
To run the optional external loopback test on IEEE 1284
compliant parallel port device, a passive loopback connector must be installed on the printer port.
Note - The external loopback test for
IEEE 1284 compliant parallel port device is intended for Sun internal manufacturing use only. It requires a
custom loopback connector not available to an external customer.
|
Large PostScript files or raster files may require that the
printer has 2 MB or more of memory. Otherwise, the printout may appear on two different sheets of paper
pptest Subtests
pptest supports the following subtests.
TABLE 39-1
Subtest
|
Description
|
Internal Test FIFO Loopback
|
Verifies DMA and PIO accesses to the
ecpp device. It uses an Internal Test FIFO on the ecpp device. There are no
printer or loopback connectors required. This test is always
executed on an
IEEE 1284 compatible printer
device.
|
External Passive Loopback
|
This verifies the parallel port I/O
connections to the back panel connector. This test requires a passive
loopback connector (Sun part no. 270-2965-01). This
test is disabled by default and must be manually enabled by the user. The
test is supported only on an IEEE 1284 compatible printer device.
Note: The external loopback test is intended
for Sun internal manufacturing use only. It requires a custom loopback
connector that is not available to an external customer.
|
Printer test
|
This verifies the parallel port
printer operation. It
outputs a half
page of data. The user must
verify that
data printed properly.
This test is disabled by
default and
must be manually enabled by
the user.
|
pptest Options
To reach the dialog box below, right-click on the test name
in the System Map and select Test Parameter Options. If you do not see this test in the System Map, you
might need to expand the collapsed groups, or your system may not include the device appropriate to this
test. Refer to the SunVTS User's Guide for more details.
FIGURE 39-1 pptest Test Parameter Options Dialog Box
TABLE 39-2
pptest Options
Options
|
Description
|
External Loopback
|
Enables or disables the external
loopback test. This test requires a special loopback plug. This option is
available only for IEEE 1284 parallel port printer.
|
Printer
|
Enables or disables the printer
test; this test requires a printer to be
attached to the parallel
port.
|
Printer_data_type
|
Choose whether ASCII text or
PostScript data is sent to the printer. The printer test must be
enabled for this to be meaningful. A postscript printer must be attached to
print postscript data. This option is available only for IEEE 1284
compatible parallel printer.
|
Printer_delay_seconds
|
Allows the user to choose a delay between
passes of the printer test. This prevents continuous printing of data
that could quickly empty the paper supply. This is
only meaningful if the printer test is enabled. This option is available only
for IEEE 1284 compatible parallel printer.
|
Interrnal_loop_during_delay
|
Enables the Internal Test FIFO loopback
test during the printer delay time. This is only meaningful
if the printer test is enabled. This option is available only for
IEEE 1284 compatible parallel printer.
|
Mode
|
Sets the print intervals.
This option lets you select the intervals at which the test
image is printed. The choices are:
- fast-prints an image every 10 seconds.
- medium-prints an image every 12 minutes.
- extended-prints an image every 30 minutes.
|
pptest Test Modes
pptest test supports Connection and Functional test modes.
TABLE 39-3
Supported Test Modes
Test Mode
|
Description
|
Connection
|
Opens and closes the parallel port device. No data
is transferred. The test passes if the device can be open and closed
successfully. The test also passes if the device cannot be opened because the
device is busy with another process.
|
Functional
|
The testing done in this mode registers a
failure if the port is found busy. This is because SunVTS tests make the assumption
that all the resources will be available for testing in the
Functional test and therefore the unavailability of the device is
interpreted as an indication of a fault condition. On ecpp(7D) devices the test runs
the internal loopback test and the test can optionally run the external
loopback test or the printer test.
|
pptest Command Line Syntax
/opt/SUNWvts/bin/sparcv9/pptest standard_arguments
-o dev=dev-name, ext_loop=Enable|Disable, printer=Enable|Disable, data=ascii, postscript, delay=0-86400, dloop=Enable|Disable, mode=fast|medium|extended
TABLE 39-4
pptest Command Line Syntax
Argument
|
Description
|
dev=dev-name
|
This is the target device name. The test runs on the
specified device name. For Ex. dev=ecpp0 will execute the test on /dev/ecpp0 device.
|
ext_loop=Enable|Disable
|
This option is available only for IEEE 1284 complaint
parallel port device. If enabled, the external loopback test is run. The external
loopback plug must be attached to the printer port.
|
printer=Enable|Disable
|
The option is available only for IEEE 1284 complaint
parallel port device. If enabled, the printer test is run. A parallel port printer
must be attached.
|
data=ascii,postscript
|
This option is available only for IEEE 1284 complaint
parallel port device. Choose whether ASCII text or PostScript data is sent to
the
printer. A PostScript printer must
be attached to print postscript data.
|
delay=0-86400
|
This option is available only for IEEE 1284 complaint
parallel port device. Allows the user to choose a delay between passes of the
printer test. This prevents continuous printing of data that
could quickly empty the paper supply.
|
dloop=Enable|Disable
|
This option is available only for IEEE 1284 complaint
parallel port device. If enabled, the printer internal loopback test is run during
the print delay duration.
|
mode=fast|medium|extended
|
The option is available only for non IEEE 1284
complaint parallel port device. Sets the test image print rate.
Possible rates are as follows:
- fast-The option prints an
image every 10 seconds.
- medium-The option prints an
image every 12 minutes.
- extended-The option prints an image every 30 minutes.
|
SunVTS 6.0 Test
Reference Manual
|
817-7665-10
|
|
Copyright © 2005, Sun Microsystems, Inc. All