The following common failures can occur before the job is submitted:
Target server is not initialized
Solution:Check whether the add server feature osmonitor command was issued and whether it succeeded.
Another running job on the target server
Solution:Only one job is allowed at a time on a server. Try again after the job completes.
Update is incompatible with operating system on target server
Solution:Check whether the OS type of the target server matches one of the update OS types. Type show update update-name at the N1–ok> prompt to view the OS type for the update.
Target server is not in a good state or is powered off
Solution:Check whether the target server is up and running. Type show server server-name at the N1–ok> prompt to view the server status. Type reset server server-name force to force a reboot.