Sun N1 System Manager 1.3.1 Troubleshooting Guide

Chapter 4 Managed Server Firmware Problems

This chapter lists problems that can occur with manageable server firmware, their causes, and the solution for each problem. The following topics are discussed:

Cannot Determine the Firmware Version on a Managed Server

If the firmware version cannot be reported by the N1 System Manager, one or all of the following situations might be the cause:

Exception Occurs When Updating Sun Fire V20z Firmware

Starting with Sun Fire V20z Firmware Version 2.2, the firmware versions do not support the PIC firmware upgrade. The upgrade of PIC firmware will fail, and the job step will show the following error message.


An exception occurred trying to update SP-IPaddress. 
Please refer to the log file for more information.

When updating Sun Fire V20z firmware, do not load PIC firmware to the Sun Fire V20z servers.

Firmware Update for a Sun Fire V20z or Sun Fire V40z Fails