Sun N1 System Manager 1.3.3 Release Notes

Rediscovery of Sun Fire X2100 M2 Systems Fail (6489463)

If you delete an existing Sun Fire X2100 server from N1 System Manager and try to rediscover it, the discovery might fail with the following error message in the job details: “Cannot set alert destination to N1 SM. Maximum destination count has reached.”

Workaround: You need to manually clear the alert destination on the managed node and run the discovery command again:

  1. Log in as root on the management server.

  2. Change directory to the ipmitool location.

    # cd /opt/ipmitool/bin/ipmitool

  3. Manually clear the alert destination on the managed node. You must know the root password of the managed node's SP.


    # ./ipmitool -H sp-ip -U root -I lan lan alert set 1 1 ipaddr 0.0.0.0
    
  4. Rediscover the server using the discover command.