This appendix provides the Sun Open Telecommunications Platform hardware and software requirements. The information in this appendix will help you to determine the operating system, hardware, and storage resources that are required to implement the Sun Open Telecommunications Platform system.
This appendix discusses the following topics:
The following table lists the minimum Sun OTP system server requirements. Ensure that the Sun OTP provisioning server meets the following partitioning requirements.
Table B–1 Sun OTP System Server RAM, Disk, and Connectivity Requirements
Category |
Requirement |
---|---|
Minimum physical memory |
4 GB |
Minimum disk space |
provisioning server: 32 GB Sun OTP host: 72 GB |
Ethernet connectivity for management interfaces |
10/100 connection |
Ethernet connectivity for provisioning and data interfaces |
10/100/1000 connection |
The following table lists the system requirements for Sun OTP system servers.
Table B–2 Sun OTP SystemServer Hardware, Operating System, Patch, and Firmware Requirements
Hardware |
Management Port |
OS |
Patch |
Firmware |
---|---|---|---|---|
NetraTM 240 |
Advanced Lights Out Manager (ALOM) |
Solaris 10 Update 3, 64 bit |
121683-04 |
OBP 4.22.23, POST 4.22.23, OBDIAG 4.22.23 |
Netra 440 |
ALOM |
Solaris 10 Update 3, 64 bit |
121685-02 |
OBP 4.22.19, POST 4.22.19, OBDIAG 4.22.19 |
Sun FireTM V210 |
ALOM |
Solaris 10 Update 3, 64 bit |
121683-04 |
OBP 4.22.23, POST 4.22.23, OBDIAG 4.22.23 |
Sun Fire V215 |
ALOM |
Solaris 10 Update 3, 64 bit |
121683-04 |
OBP 4.22.23, POST 4.22.23, OBDIAG 4.22.23 |
Sun FireV240 |
ALOM |
Solaris 10 Update 3, 64 bit |
121683-04 |
OBP 4.22.23, POST 4.22.23, OBDIAG 4.22.23 |
Sun Fire V245 |
ALOM |
Solaris 10 Update 3, 64 bit |
121692-02 |
OBP 4.22.22, POST 4.22.22, OBDIAG 4.22.22 |
Sun Fire V440 |
ALOM |
Solaris 10 Update 3, 64 bit |
121685-02 |
OBP 4.22.19, POST 4.22.19, OBDIAG 4.22.19 |
Sun Fire V445 |
ALOM |
Solaris 10 Update 3, 64 bit |
121690-03, 123485-01 |
OBP 4.22.24, POST 4.22.24, OBDIAG 4.22.24, 1.0.39 |
Sun Fire V490 |
Remote System Control (RSC) |
Solaris 10 Update 3, 64 bit |
121689-01 |
OBP 4.22.19, POST 4.22.19, OBDIAG 4.22.19 |
Sun Fire V890 |
RSC/ALOM |
Solaris 10 Update 3, 64 bit |
121688-01 |
OBP 4.22.19, POST 4.22.19, OBDIAG 4.22.19 |
Sun Fire T2000 |
ALOM |
Solaris 10 Update 3, 64 bit |
124750-03 |
Sun System Firmware 6.3.2 for non-LDOM support Sun System Firmware 6.4.6 for LDOM support |
Sun Fire X2100 M2 |
Embedded Lights Out Manager (ELOM) |
Solaris 10 Update 3, 64 bit |
Sun Fire X2200 M2 Server Tools & Driver 1.5a ISO Image |
BIOS - 3A15, SP - 2.91 |
Sun Fire X2200 M2 |
ELOM |
Solaris 10 Update 3, 64 bit |
Sun Fire X2100 M2 Server 1.5 CD ISO Release |
BIOS - 3B16, SP - 2.91 |
Sun Fire X4100 M2 |
Integrated Lights Out Manager (ILOM) |
Solaris 10 Update 3, 64 bit |
Sun Fire X4100 M2 and Sun Fire X4200 M2 Servers Supplemental 1.2 |
LSI MPT SAS firmware 1.16.40, MPT BIOS 6.14.04, and SP Firmware 1.1.8 |
Sun Fire X4200 M2 |
ILOM |
Solaris 10 Update 3, 64 bit |
Sun Fire X4100 M2 and Sun Fire X4200 M2 Servers Supplemental 1.2 |
LSI MPT SAS firmware 1.16.40, MPT BIOS 6.14.04, and SP Firmware 1.1.8 |
Netra T2000 |
ALOM |
Solaris 10 Update 3, 64 bit |
126401-02 |
Sun System Firmware 6.3.2 for non-LDOM support Sun System Firmware 6.4.6 for LDOM support |
On SPARC systems, Sun OTP supports from 1 to 16-host clusters. On x64 systems, Sun OTP supports from 1 to 4–host clusters.
The following table lists the hardware qualified by Sun OTP.
Table B–3 Sun OTP Qualified Hardware
Hardware |
Storage |
NIC |
---|---|---|
Sun Fire V210 |
Sun StorEdge 3120 SCSI (JBOD) Sun StorEdge 3310 SCSI (RAID) Sun StorEdge 3310 SCSI (JBOD) Sun StorEdge 3320 SCSI (JBOD) Sun StorEdge 3510 FC Array (RAID) Sun StorEdge 3511 FC Array (RAID-SATA) |
On-board GE X4445A QGE X4150A-2 GE Cu X4422A-2 Combo |
Sun Fire V240 |
Sun StorEdge 3120 SCSI (JBOD) Sun StorEdge 3310 SCSI (RAID) Sun StorEdge 3310 SCSI (JBOD) Sun StorEdge 3320 SCSI (RAID) Sun StorEdge 3320 SCSI (JBOD) Sun StorEdge 3510 FC Array (RAID) Sun StorEdge 3511 FC Array (RAID-SATA) Sun StorEdge 6130 Sun StorageTek 6140 |
On-board GE X4445A QGE X4150A-2 GE Cu X4422A-2 Combo |
Netra 240 |
Sun StorEdge 3120 SCSI (JBOD) Sun StorEdge 3310 SCSI (JBOD) Sun StorEdge 3320 SCSI (RAID) Sun StorEdge 3320 SCSI (JBOD) Sun StorEdge 3510 FC Array (RAID) Sun StorEdge 3511 FC Array (RAID-SATA) |
On-board GE X4445A QGE X4150A-2 GE Cu X4422A-2 Combo |
Sun Fire V215 |
Sun StorEdge 3310 SCSI (RAID) Sun StorEdge 3320 SCSI (RAID) Sun StorEdge 3510 FC Array (RAID) Sun StorageTek 6140 |
On-board GE X4150A-2 GE Cu X4445A QGE X4422A-2 Combo X7280A-2 GE Cu |
Sun Fire V245 |
Sun StorEdge 3310 SCSI (RAID) Sun StorEdge 3320 SCSI (RAID) Sun StorEdge 3510 FC Array (RAID) Sun StorEdge 6130 Sun StorageTek 6140 |
On-board GE X4150A-2 GE Cu X4445A QGE X4422A-2 Combo X7280A-2 GE Cu |
Sun Fire X2100 M2 |
Sun StorEdge 3310 SCSI (RAID) Sun StorEdge 3310 SCSI (JBOD) Sun StorEdge 3510 FC Array (RAID) Sun StorEdge 3511 FC Array (RAID-SATA) Sun StorEdge 6130 Sun StorageTek 6140 |
On-board GE X7280A-2 GE Cu |
Sun Fire X2200 M2 |
Sun StorEdge 3310 SCSI (RAID) Sun StorEdge 3310 SCSI (JBOD) Sun StorEdge 3510 FC Array (RAID) Sun StorEdge 3511 FC Array (RAID-SATA) Sun StorEdge 6130 Sun StorageTek 6140 |
On-board GE X7280A-2 GE Cu |
Sun Fire V440 |
Sun StorEdge 3120 SCSI (JBOD) Sun StorEdge 3310 SCSI (RAID) Sun StorEdge 3310 SCSI (JBOD) Sun StorEdge 3320 SCSI (RAID) Sun StorEdge 3320 SCSI (JBOD) Sun StorEdge 3510 FC Array (RAID) Sun StorEdge 6130 Sun StorageTek 6140 |
On-board GE X4445A QGE X4150A-2 GE Cu X4422A-2 Combo |
Netra 440 |
Sun StorEdge 3310 SCSI (RAID) Sun StorEdge 3310 SCSI (JBOD) Sun StorEdge 3320 SCSI (RAID) Sun StorEdge 3320 SCSI (JBOD) Sun StorEdge 3510 FC Array (RAID) |
On-board GE X4445A QGE X4150A-2 GE Cu X4422A-2 Combo |
Sun Fire V490 |
Sun StorEdge 3310 SCSI (RAID) Sun StorEdge 3320 SCSI (RAID) Sun StorageTek 6140 |
On-board GE X4445A QGE X4150A-2 GE Cu X4422A-2 Combo |
Sun Fire T2000 |
Sun StorEdge 3120 SCSI (JBOD) Sun StorEdge 3310 SCSI (RAID) Sun StorEdge 3510 FC Array (RAID) Sun StorEdge 6130 Sun StorageTek 6140 |
On-board GE X4150A-2 GE Cu |
Netra T2000 |
Sun StorEdge 3511 FC Array (RAID-SATA) Sun StorEdge 6130 Sun StorageTek 6140 |
On-board GE X4150A-2 GE Cu |
Sun Fire V445 |
Sun StorEdge 3320 SCSI (RAID) Sun StorEdge 3510 FC Array (RAID) Sun StorageTek 6140 |
On-board GE X4150A-2 GE Cu X4445A QGE X4422A-2 Combo X7280A-2 GE Cu |
Sun Fire X4100 M2 |
Sun StorEdge 3120 SCSI (JBOD) Sun StorEdge 3320 SCSI (RAID) Sun StorEdge 3510 FC Array (RAID) Sun StorageTek 6140 |
On-board GE X7280A-2 GE Cu |
Sun Fire X4200 M2 |
Sun StorEdge 3120 SCSI (JBOD) Sun StorEdge 3510 FC Array (RAID) Sun StorEdge 6130 Sun StorageTek 6140 |
On-board GE X7280A-2 GE Cu |
Netra X4200 M2 |
Sun StorEdge 3510 FC Array (RAID) Sun StorEdge 3511 FC Array (RAID-SATA) Sun StorEdge 6130 Sun StorageTek 6140 |
On-board GE X7280A-2 GE Cu |
Sun Fire V890 |
Sun StorEdge 3310 SCSI (RAID) Sun StorEdge 3320 SCSI (RAID) Sun StorageTek 6140 |
On-board GE X4445A QGE X4150A-2 GE Cu X4422A-2 Combo |
The following table lists the storage device firmware requirements.
Table B–4 Sun OTP System Storage Device Firmware Requirements
Type |
Patch |
Requirement |
---|---|---|
StorEdgeTM 3510 FC |
RAID 113723-15, JBOD 113662-01 |
Version 2.4 of the sccli CLI utility must be installed first. |
StorEdge 3511 FC |
113724-09 |
Version 2.4 of the sccli CLI utility must be installed first. |
StorEdge 3120 SCSI |
113728-02 array controller firmware |
Version 2.4 of the sccli CLI utility must be installed first. |
StorEdge 3310 SCSI |
113722-15 |
Version 2.4 of the sccli CLI utility must be installed first. |
StorEdge 3320 SCSI |
113730-01 |
Version 2.4 of the sccli CLI utility must be installed first. |
StorEdge 6130 FC |
118185-15 6130 services release, 117856-19 6130 baseline firmware release |
StorEdge 6130 array firmware upgrader patch 118185-15 must be installed first. |
StorageTek 6140 FC |
120337 5.1.0.11 baseline firmware release |
Available through the Common Array Manager (CAM) software package. |