Sun Open Telecommunications Platform 2.0 Installation Guide

Appendix B Sun OTP Hardware and Software Requirements

This appendix provides the Sun Open Telecommunications Platform hardware and software requirements. The information in this appendix will help you to determine the operating system, hardware, and storage resources that are required to implement the Sun Open Telecommunications Platform system.

This appendix discusses the following topics:

Sun OTP System Requirements

The following table lists the minimum Sun OTP system server requirements. Ensure that the Sun OTP provisioning server meets the following partitioning requirements.

Table B–1 Sun OTP System Server RAM, Disk, and Connectivity Requirements

Category 

Requirement 

Minimum physical memory 

4 GB 

Minimum disk space 

provisioning server: 32 GB 

Sun OTP host: 72 GB 

Ethernet connectivity for management interfaces 

10/100 connection 

Ethernet connectivity for provisioning and data interfaces 

10/100/1000 connection 

The following table lists the system requirements for Sun OTP system servers.

Table B–2 Sun OTP SystemServer Hardware, Operating System, Patch, and Firmware Requirements

Hardware 

Management Port 

OS 

Patch 

Firmware 

NetraTM 240

Advanced Lights Out Manager (ALOM) 

Solaris 10 Update 3, 64 bit 

121683-04 

OBP 4.22.23, POST 4.22.23, OBDIAG 4.22.23 

Netra 440  

ALOM 

Solaris 10 Update 3, 64 bit 

121685-02 

OBP 4.22.19, POST 4.22.19, OBDIAG 4.22.19 

Sun FireTM V210

ALOM 

Solaris 10 Update 3, 64 bit 

121683-04 

OBP 4.22.23, POST 4.22.23, OBDIAG 4.22.23 

Sun Fire V215 

ALOM 

Solaris 10 Update 3, 64 bit 

121683-04 

OBP 4.22.23, POST 4.22.23, OBDIAG 4.22.23 

Sun FireV240 

ALOM 

Solaris 10 Update 3, 64 bit 

121683-04 

OBP 4.22.23, POST 4.22.23, OBDIAG 4.22.23 

Sun Fire V245 

ALOM 

Solaris 10 Update 3, 64 bit 

121692-02 

OBP 4.22.22, POST 4.22.22, OBDIAG 4.22.22 

Sun Fire V440 

ALOM 

Solaris 10 Update 3, 64 bit 

121685-02 

OBP 4.22.19, POST 4.22.19, OBDIAG 4.22.19 

Sun Fire V445 

ALOM 

Solaris 10 Update 3, 64 bit 

121690-03, 123485-01 

OBP 4.22.24, POST 4.22.24, OBDIAG 4.22.24, 1.0.39 

Sun Fire V490 

Remote System Control (RSC) 

Solaris 10 Update 3, 64 bit 

121689-01 

OBP 4.22.19, POST 4.22.19, OBDIAG 4.22.19 

Sun Fire V890 

RSC/ALOM 

Solaris 10 Update 3, 64 bit 

121688-01 

OBP 4.22.19, POST 4.22.19, OBDIAG 4.22.19 

Sun Fire T2000 

ALOM 

Solaris 10 Update 3, 64 bit 

124750-03 

Sun System Firmware 6.3.2 for non-LDOM support 

Sun System Firmware 6.4.6 for LDOM support 

Sun Fire X2100 M2 

Embedded Lights Out Manager (ELOM) 

Solaris 10 Update 3, 64 bit 

Sun Fire X2200 M2 Server Tools & Driver 1.5a ISO Image 

BIOS - 3A15, SP - 2.91 

Sun Fire X2200 M2 

ELOM 

Solaris 10 Update 3, 64 bit 

Sun Fire X2100 M2 Server 1.5 CD ISO Release 

BIOS - 3B16, SP - 2.91 

Sun Fire X4100 M2 

Integrated Lights Out Manager (ILOM) 

Solaris 10 Update 3, 64 bit 

Sun Fire X4100 M2 and Sun Fire X4200 M2 Servers Supplemental 1.2 

LSI MPT SAS firmware 1.16.40, MPT BIOS 6.14.04, and SP Firmware 1.1.8 

Sun Fire X4200 M2 

ILOM 

Solaris 10 Update 3, 64 bit 

Sun Fire X4100 M2 and Sun Fire X4200 M2 Servers Supplemental 1.2 

LSI MPT SAS firmware 1.16.40, MPT BIOS 6.14.04, and SP Firmware 1.1.8 

Netra T2000 

ALOM 

Solaris 10 Update 3, 64 bit 

126401-02 

Sun System Firmware 6.3.2 for non-LDOM support 

Sun System Firmware 6.4.6 for LDOM support 


Note –

Sun OTP Qualified Hardware

The following table lists the hardware qualified by Sun OTP.

Table B–3 Sun OTP Qualified Hardware

Hardware 

Storage 

NIC 

Sun Fire V210 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3320 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 3511 FC Array (RAID-SATA) 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

Sun Fire V240 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3320 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 3511 FC Array (RAID-SATA) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

Netra 240 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3320 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 3511 FC Array (RAID-SATA) 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

Sun Fire V215 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorageTek 6140 

On-board GE 

X4150A-2 GE Cu 

X4445A QGE 

X4422A-2 Combo 

X7280A-2 GE Cu 

Sun Fire V245 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X4150A-2 GE Cu 

X4445A QGE 

X4422A-2 Combo 

X7280A-2 GE Cu 

Sun Fire X2100 M2 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 3511 FC Array (RAID-SATA) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X7280A-2 GE Cu 

Sun Fire X2200 M2 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 3511 FC Array (RAID-SATA) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X7280A-2 GE Cu 

Sun Fire V440 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3320 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

Netra 440 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3310 SCSI (JBOD) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3320 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

Sun Fire V490 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorageTek 6140 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

Sun Fire T2000 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X4150A-2 GE Cu 

Netra T2000 

Sun StorEdge 3511 FC Array (RAID-SATA) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X4150A-2 GE Cu 

Sun Fire V445 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorageTek 6140 

On-board GE 

X4150A-2 GE Cu 

X4445A QGE 

X4422A-2 Combo 

X7280A-2 GE Cu 

Sun Fire X4100 M2 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorageTek 6140 

On-board GE 

X7280A-2 GE Cu 

Sun Fire X4200 M2 

Sun StorEdge 3120 SCSI (JBOD) 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X7280A-2 GE Cu 

Netra X4200 M2 

Sun StorEdge 3510 FC Array (RAID) 

Sun StorEdge 3511 FC Array (RAID-SATA) 

Sun StorEdge 6130 

Sun StorageTek 6140 

On-board GE 

X7280A-2 GE Cu 

Sun Fire V890 

Sun StorEdge 3310 SCSI (RAID) 

Sun StorEdge 3320 SCSI (RAID) 

Sun StorageTek 6140 

On-board GE 

X4445A QGE 

X4150A-2 GE Cu 

X4422A-2 Combo 

The following table lists the storage device firmware requirements.

Table B–4 Sun OTP System Storage Device Firmware Requirements

Type 

Patch 

Requirement 

StorEdgeTM 3510 FC

RAID 113723-15, JBOD 113662-01 

Version 2.4 of the sccli CLI utility must be installed first.

StorEdge 3511 FC 

113724-09 

Version 2.4 of the sccli CLI utility must be installed first.

StorEdge 3120 SCSI 

113728-02 array controller firmware 

Version 2.4 of the sccli CLI utility must be installed first.

StorEdge 3310 SCSI 

113722-15 

Version 2.4 of the sccli CLI utility must be installed first.

StorEdge 3320 SCSI 

113730-01 

Version 2.4 of the sccli CLI utility must be installed first.

StorEdge 6130 FC 

118185-15 6130 services release, 117856-19 6130 baseline firmware release 

StorEdge 6130 array firmware upgrader patch 118185-15 must be installed first. 

StorageTek 6140 FC 

120337 5.1.0.11 baseline firmware release 

Available through the Common Array Manager (CAM) software package.