Skip Headers
Oracle® Argus Safety Administrator's Guide
Release 6.0.1

E15950-03
Go to Documentation Home
Home
Go to Book List
Book List
Go to Table of Contents
Contents
Go to Feedback page
Contact Us

Go to previous page
Previous
Go to next page
Next
PDF · Mobi · ePub

4 System Configuration

This chapter provides information about configuring the system for use. It includes discussions about how to configure the following:

System Configuration Overview

This following table describes how the following system options are configured:

Section Description
Case Priority This screen enables the administrator to configure rules to determine the priority of new cases that are entered into the system.
Field Validation This screen enables the administrator to configure field level validations for the Case Form fields.
Field Labels This screen enables the administrator to configure field labels.
LAM System Numbering This section enables the administrator to specify the case numbering preferences for LAM cases.
System Management (Common Profile Switches) This screen enables the administrator to configure common profile switches.
Workflow This screen enables the administrator to configure Workflow states and rules.
System Numbering This screen enables the administrator to specify the case numbering preferences.
SMTP This screen enables the administrator to configure SMTP for e-mails

Configuring Case Priority

This screen enables you to configure rules to determine the priority of new cases that are entered into the system. Based on these rules, the system assigns each case a priority that is displayed in the Worklist.

Each row in the Case Priority Configuration screen represents the priority level assigned to a case that meets the specific criteria selected for that level. This data is reflected in multiple expedited and periodic reports and case form-product information section.

  • The user can select the priority level for which the criterion is to be configured.

  • Select System Configuration --> Case Priority to view the Case Priority page.

Surrounding text describes casepriority.gif.

Field Descriptions

The following table lists and describes the fields in this section.

Field/Control Name Description
Priority Enables the user to select the priority level whose criterion is to be configured.

The user can disable only the last enabled priority. Example: If a user has priority 1-4 checked, the priority can be disabled only in the order of 4-1.

Case Assessment - Serious Enables the user to configure the seriousness for case assessment.
  • Select Yes from the drop-down list to give priority to cases that are serious.

  • Select No for non-serious cases to be considered for this priority level. Seriousness is considered at the case level.

  • Select Ignore from the drop-down list to ignore this condition when assessing the priority of this case.

Case Assessment - Unlisted Enables the user to configure the priority level for unlisted case assessment.
  • Select Yes from the drop-down list for unlisted cases to be considered for this priority level.

  • Select No for listed cases to be considered for this priority level. Listedness criteria is considered at the case level.

  • Select Ignore from the drop-down list to ignore this condition when assessing the priority of this case.

Case Assessment - Causal Enables the user to configure the priority level for causal case assessment.
  • Select Yes from the drop-down list for causal cases to be considered for this priority level.

  • Select No for non-causal cases to be considered for this priority level. Causality criteria is considered at the case level.

  • Select Ignore from the drop-down list to ignore this condition when assessing the priority of this case.

Report Due Date-Due Soon Enables the user to configure the report date due soon.

If this option is selected, the case is given the specified priority if at least one expedited report is due after the number of warning days specified from the current system date.

First Report Due Date - Ignore Enables the user to configure the first report due date to ignore status.

This option is used to ignore this parameter when assessing the priority.

No. of Warning Days Before Due Enables the user to enter the number of days before a case's report due date when the priority is raised to Due Soon.
Advance Condition Drop Down List Box Enables the user to select an existing advance condition from the drop-down list.
Select Button Enables the user to create a new advanced condition set or modify an existing one.
Run All Case Priority Determination on Middle Tier Enables the user to run all case priority determination on Middle Tier.
  • If unchecked, the application assesses priority during every case save operation in Web.

  • If checked, the application does NOT assess priority during every case save operation in Web and Client/Server.


To configure Case Priority

  1. Select the priority level whose criterion is to be configured.

  2. Select the Case Assessment - Serious. The options in the drop-down list are Yes, No, Ignore.

  3. Select the Case Assessment - Listed. The options in the drop-down list are Yes, No, Ignore.

  4. Select the Case Assessment - Casual. The options in the drop-down list are Yes, No, Ignore.

  5. Select First Report Due Date as Due Soon or Ignore. Enter the #Warning days for Due Soon.

  6. Select the Advanced Conditions from the drop-down list.

  7. Use Select icon to create a new Advanced Condition.

  8. Select Run All Case Priority Determination on Middle Tier to ensure that the application does not assess priority when a case is saved in Web and Client/Server.

  9. Click Save to save the changes made.

Configuring Field Validations

This screen enables you to configure field level validations for the Case Form fields. Be aware of the following:

  • These validation rules are expressed as an advanced condition, with their criteria marked as required or warning.

  • The field level validations feature helps in automatic checking of data as it is entered on the Case Form, to ensure consistency of data as per company requirements. Consider the following example:

    Suppose that the year in the patient's date of birth is entered as 1860. The patient's date of birth probably could not have been prior to 1880; hence, a warning is issued to ensure the accuracy of the entered data.

  • A field level validation message such as this one is a "warning violation" and the user can therefore enter a justification and continue working on the case.

  • An example of a mandatory violation would be a dosage regimen stop date that occurs before the dosage regimen start date. Cases cannot be saved without correcting mandatory violations.

  • For dependent fields, Argus Safety is pre-loaded with several field level validations. Some of these validations are protected and cannot be disabled. Others can be disabled, if required by company policy.

  • The system displays the Advance Condition Description for field validations on the case form after the Advanced Condition name in the following format: Field: XXXX:YYYYReason: ZZZZ

where:

XXXX Is the Field Label Tree view followed by the field label as configured in the field label configuration.
YYYY Is the Advance Condition name configured for the field validation.
ZZZZ Is the advance condition description as configured for the Advance conditions?

This text prints only if there is a description available for the Advanced Condition. Otherwise, the system disables the field label.


Surrounding text describes caseformvalids.gif.

Select System Configuration->Field Validation to view the Case Form Field Level Validation screen. The following is an illustration of the screen.

Surrounding text describes fieldvalids.gif.

Tip:

The Case Form tabs appear on the left panel and are categorized as folders. Each folder contains all the field labels associated with that section.

Consider the following example:

The General Tab in the Case Form contains sections such as Study, Follow-up, Case Literature, etc. To view the list of field names associated with the Study section, click Study in the left panel. The field names associated with Study appear in the right panel.

Field Descriptions

The following table lists and describes the fields in this section.

Field/Control Name Description
Field Displays the name of the field.
Condition for Warning Displays the advanced condition for warning.
Table Displays the name of the selected sub-folder as displayed in the browser tree view. This field cannot be edited.
Field Displays the name of the selected field label in the browser tree-view. This field cannot be edited.
Condition for Warning Displays the advanced condition for warning.
Condition for Mandatory Exception Displays the advanced condition for mandatory exception.
Print All Displays a list of validations on all tables, fields and advanced conditions of each Group in the Case Form as a PDF.

Modifying Field Validations

This section enables the user to edit the information already entered in fields.

To modify a field validation

  1. Select the Case Form folder and field for which, the validation rule is to be modified.

    Tip:

    The information of the selected field is displayed in the Modify section.
  2. Click Select icon to create/select advanced conditions for Condition for Warning and Condition for Mandatory Exception.

    Tip:

    Click here for details on Advanced Conditions.

    Note:

    • If all validation rules are met, a green icon is displayed.

    • If a condition for warning is met during field validation, an orange icon is displayed.

    • If a condition for mandatory exception is met during field validation, a red icon is displayed.

  3. Click Save to save the changes made.

    Note:

    Label Changes will not be reflected in Argus Case Form unless IIS is reset.

Configuring LAM System Numbering

This section enables you to specify the case numbering preferences for LAM cases. The system provides the ability to use multiple case numbering schemes for global use. For example, if site is used in the numbering, the system provides the option to keep separate sequences for each site.

Select System Configuration->LAM System Numbering to view the LAM System Numbering screen shown in the following illustration.

Surrounding text describes lamsysn.gif.

Field Descriptions

The following table lists and describes the fields in this section.

Field/Control Name Description
Manually Number Cases This option enables the user to manually number the cases on booking or while copying the case, using the "save as" option on the case form.
Automatically Number Cases On selection, the system automatically numbers the cases as defined by the user in the numbering format.
Start at Enables the user to initialize the counter of the sequence number.
Separate sequence for each site Enables the user to separate the sequence numbering for cases on site by site basis. If there are cases being entered from two different sites then each site will have different sequencing of case numbers.
Separate sequence for each report type Enables the user to separate the sequence numbering for cases by the report type of the case.
Separate sequence for each year Enables the user to reset the sequence numbering for cases after each year, based on the initial receipt date of the case.
Separate sequence for each month Enables the user to reset the sequence numbering for cases after each month, based on the initial receipt date of the case.
Separate sequence for each product abbreviation Enables the user to reset the sequence numbering for cases for each different product abbreviation.
Numbering Format Enables the user to select the numbering format by selecting the different placeholders.
  • Define the numbering format by typing in custom keywords to print on every case number and selecting different placeholders.

  • [YY][MM]-[###] is the default format.

Placeholder Enables the user to enter a placeholder.
  • Placeholders are used to pickup values from the database to be used in the Case numbering format.

  • Possible values in this list include:

    • # - Number: defines the digits to be used as the sequence number in the format. The field is used to display the sequence number on the case numbers.

    • CC- Country code: When selected, this uses the A2 code for the country of incidence for the case number.

    • DD - Day: When selected, this uses the date of the "Initial receipt date" field of the case.

    • MM - month: When selected, this uses the month of the Initial receipt date' field of the case.

    • P -When selected, this uses either of the two values:

      If report type is Spontaneous or other during booking: the system uses the value of the Product Abbreviation' field specified in the Product configuration for the selected Primary suspect product.

    • SSS – User Site: When selected this uses the Site abbreviation of the site belonging to the user who booked in the case.

    • TTT – Report Type: When selected this uses the report type abbreviation of the report type selected during bookin of the case.·

    • YY- Year: When selected, this uses the year of the Initial receipt date' field of the case.


To configure LAM numbering

  1. Select the Numbering feature as required. This can be manual numbering or automatic numbering of cases.

  2. Select the Sequencing Options as required.

    Tip:

    For the complete explanation of the sequencing option refer to the Field Descriptions.
  3. Select the Numbering Format. Use Placeholders to enter the required format.

    Tip:

    To customize the Numbering Format, use the placeholder values. Consider the following example:

    To select Country Code, Month and Year (as values to be incorporated from the database) as the Case numbering format, execute the following steps.

    1. Click on Country Code. This appears in the Numbering Format field.

    2. Click on Month. This appears in the Numbering Format field next to the Country Code.

    3. Click on Year. This appears in the Numbering Format field next to the Country Code and Month.

    4. The final data listed in the Numbering Format field is the Case Numbering Format.

  4. Click Save to save the changes made.

Configuring System Management - Common Profile Switches

This section lists the configurable sections for Common Profile Switches.

Select System Configurationand thenSystem Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

Note:

If any change is made in the System Management (Common Profile Switches) screen, the Argusvr2.exe and Argusvr2a.exe should be killed from each Web Server and the IIS on Argus Web / Report Servers must be reset, in order to reflect the changes made in the Argus application.

The following table provides the list of configurable sections associated with Common Profile Switches.

Section Sub Section Description
Advanced Conditions ~ The Advanced Conditions configuration screen enables you to specify the number of rows to be displayed on the Advanced Condition search screen.
Argus J ~ The Argus J Configuration screen enables you to modify the customizable fields on the Argus J form.
Case Form Configuration ~ This screen enables you to configure Common Profile Switches that affect the behavior of the Argus application
Case Processing Assessments

Auto Archiving

Case Numbering

MedDRA Browser

Performance

This section enables you to configure the case processing fields and items.
Documentum ~ This screen enables you to configure the Documentum fields and items for Documentum.
Documentum Login ~ Enables the user to configure the Documentum login.
Enable Storage of E2B Reports in Documentum ~ Enables the user to indicate whether E2B reports should be stored in Documentum. The user selects Yes or No.
Enable Storage of Submitted Expedited Reports in Documentum ~ Enables the user to indicate whether submitted expedited reports should be stored in Documentum. The user selects Yes or No.
Enable Storage of Case Attachment Files in Documentum ~ Enables the user to indicate whether case attachment files should be stored in Documentum. The user selects Yes or No.
Enable Storage of Submitted Periodic Reports in Documentum ~ Enables the user to indicate whether submitted periodic reports should be stored in Documentum. The user selects Yes or No.
E2B ~ This screen enables you to configure the E2B fields and items for E2B.
Local Labeling LAM The Local Labeling Configuration screen enables you to modify the options available through local labeling.
MedWatch Configuration ~ The MedWatch Configuration screen enables you to modify the customizable fields on the MedWatch form.
Reporting Expedited

Expedited BfArM

Expedited Canada

Expedited CIOMS

Expedited MedWatch

Periodic

Scheduling

The Reporting Configuration screen enables you to modify the options available for reporting.
Security ~ The Security Configuration screen enables you to modify the options available for security.
User Interface ~ The User Interface screen enables you to modify the options available for User Interface.
Workflow ~ The Workflow Items screen enables you to modify the options available for Workflow Items.

Configuring Advanced Conditions

The Argus J Configuration screen enables you to modify the customizable fields on the Argus J form.

Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the rows to display on each page of an advanced condition screen, click the Advanced Conditions folder in the left panel.

Surrounding text describes cpnc.gif.

Field Descriptions

The following table lists and describes the fields in Advanced Conditions Configuration.

Field/Control Name Description
Number of rows to display per page on the Advanced Condition Search screen Enables the user to specify the number of rows to be displayed on the Advanced Condition search screen.

To configure Advanced Conditions

  1. Enter the Number of rows to display per page on the Advanced Conditions Search screen.

  2. Click Save to save the changes made.

Configuring Argus J

The Argus J Configuration screen enables you to modify the customizable fields on the Argus J form.

Select System Configuration->System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To view the list of field names associated with the Argus J section, click the Argus J folder in the left panel. The field names associated with Argus J Configuration appears in the right panel as shown in the following illustration. Surrounding text describes jargusjconfig.gif.

The following table lists and describes the fields on the Modify Argus J screen.

Field Name Description
Enable half-width Alphanumeric characters forced input for Alphanumeric only fields When checked, characters in specific alphanumeric fields will always be in English. When unchecked, all characters will be in Japanese characters.
Default viewing format of the PMDA E2B report (used with Interchange-J) Enables you to select the viewing format for the PMDA E2B report. Choices include the following:
  • I SGML

  • J SGML

  • I Decode View

  • J Decode View

  • PMDA Paper Form

Shared Path for the Literature Intake This profile switch enables the user to define a shared path for literature intake. Enter the appropriate path in the field.
Default Report Type to be select when Literature Intake item is booked in This profile switch enables the user to select a default report type to use when booking in a Literature Intake item.
Default Name of the Regulatory Agency for New Draft Expedited PMDA Reports from Analysis Tab of the Case Form Enables you to select the default regulatory agency that will receive the expedited PMDA reports.

Configuring Argus J E2B Profile Switches

The application enables you to configure the E2B profile switches for Argus J. Expand the Argus J folder and click E2B to open the Modify Argus J E2B window and modify the associated profile switches.

Surrounding text describes je2bprofileswitches.gif.

The following table lists and describes the fields on this screen.

Field Name Description
E2B filename extension for Interchange-J Identifies the filename extension.
Drug assessment source for reported causality The source of the drug assessment information for the reported cause.
Drug assessment source for determined causality The source of the drug assessment information for the determined cause.
Drug assessment method The method used to make the drug assessment.
Perform Japanese character validation at E2B Check and E2B Report Generation When checked, the application validates the Japanese characters in the E2B Check and in the E2B Report.
Additional invalid character to be checked in Japanese character validation. Enables you to enter a list of Japanese characters the system should validate.
Characters to be allowed to use in all (Alphanumeric) E2B Items Enables you to enter a list of alphanumeric characters that are acceptable for use in E2B items.

Configuring Argus J Reporting Profile Switches

The system enables you to configure the Reporting profile switches for Argus J. Expand the Argus J folder and click Reporting to open the Modify Argus J Reporting window and modify the associated profile switches. Surrounding text describes jrptprofileswitches.gif.

The following table lists and describes the fields on the Modify Argus J Reporting screen.

Field Name Description
Follow-Up Action Item for Incomplete Report Submission. Enables you to select the follow-up action item.
Due In Enables you to select the number of days before the report is due.
Follow-up Action Item for Incompletion Report Submission Group Assignment Enables you to assign the Incompletion report submission to a specific user group
Auto Distribution Submission Comments Enables you to enter comments regarding automatic distribution submissions.
Text to display as comment when a downgraded report is scheduled. Enables you to enter a comment to display when a report is downgraded.
Offset from GMT used to calculate Japanese date/time fields for Interchange-J (in hours) Enables you to enter the GMT offset used when calculations date/time fields.
Auto Distribution Transmission Comments Enables you to enter comments regarding the auto transmission.

Configuring Case Form (System Management)

This screen enables you to configure Common Profile Switches that affect the behavior of the Argus application. When configuring Case Form, be aware of the following:

  • The user can use the Console Field Label Configuration to configure additional fields.

  • The system tracks any field updates to fields in the audit log, and the system prints the additional fields on the print out.

  • The system also enables the user to select the Event Occurred as Consequence of field from a code.

  • The Event Occurred as Consequence of field and the Term field are required fields and must contain values.

  • The user can perform the following functions for the Event Occurred as Consequence of page:

    • Ad New

    • Copy

    • Delete

    • Print

    • Save

  • The filtering and pagination options are similar to the Code List functions.

  • The system tracks updates to fields on the Event Occurred as Consequence of page in the audit log.

  • The CASE_PRODUCT_ENCODE_BTN_TEXT field has been added to the Console.

    • The field is in the following location:

    • Console -->System Configuration-->System Management (Common Profile Switches-->User Interface (from selection tree on right).

    • The field is beneath the label for the Label for Product Select button section.

    • The field label is: Label for WHO Drug Select button.

    • The default field value is Encode.

  • The Drugs, Indication, Event Terms, J Terms, LM - Events and LM - Indications are sorted in descending order so the latest dictionary displays first.

    • This displays in the same order if the MedDRA browser is opened from the Utilities | MedDRA browser option.

    • This displays in the same order in the Study Configuration for Enable Study Specific Encoding.

  • On the Configuration User Interface and the Printout, the Update column heading has been changed to Other. This affects the following screen:

    • Console --> System Configuration --> Case Priority> Ignore column (middle of screen)

    • Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To view the list of field names associated with the Case Form Configuration section, click the Case Form Configuration folder in the left panel. The field names associated with Case Form Configuration appears in the right panel.

The Case Form Configuration dialog helps you customize the case processing activities in order to meet the company's requirements. The Administrator can configure the following items by using the Case Form Configuration dialog shown in the following illustration.

Surrounding text describes cpcfc.gif.

Auto Encoding / Central Encoding

To enable the use of standardized medical terminology throughout the adverse event reporting process, dictionaries can be used to encode certain terms in the Case Form.

The dictionaries that will be used to encode drugs, indications, and events can be specified in the Autoencoding section of the Case Form Configuration dialog.

Field Descriptions

The following table lists and describes the fields in this section.

Field/Control Name Description
Drugs The Drugs dictionary list enables the selection of the WHO-DRUG dictionary. Select the Drugs check box and tab out of the product name field in the Case Form to search the company product followed by the license trade names.
  • If no matches are found, the WHO drug dictionary (drug names) is searched.

  • Tab out of the generic name field in the Case Form to search the product/product family ingredients (it displays the select dialog if more than one product is found with the ingredient).

  • If no match is found, the WHO drug dictionary (ingredients) is searched.

Indications Select the Indications check box to enable auto encoding of primary indication for the drug encoding, Patient Condition description in Other Relevant History section and Death Details dialog.
Event Terms Select the Event Terms check box to enable you to be prompted for the term as you enter it to be encoded on the Events tab. If an exact match is found in the dictionary, the term gets populated automatically. If an exact match is not found, the Event Coding dialog is displayed to select the desired event.
Prevent manual encoding for event terms Prevents users from encoding the event terms manually.
Require event term encoding before case closure Ensures that users encode the events prior to formally closing a case.

Automation

The Automation section enables the user to generate an Auto narrative based on one of the templates configured by the method described in this topic.

Field Descriptions

The following table lists and describes the fields in the Automation dialog box.

Field/Control Name Description
Auto Regulatory Scheduling This enables the user to configure the manner in which Argus Safety handles the Auto-scheduling of Regulatory Reports.

The available options are:

  • None

  • Always

  • Significant

  • Manual

Selecting Always will run the auto-scheduling algorithm when any field from a specific list of fields is modified on the Case Form and the case is saved.

Report Generation The Report Generation option helps you to configure how the system responds to new data when generating auto-scheduled regulatory reports.
  • When new data is entered, the system re-runs the regulatory report-scheduling algorithm to determine which reporting rules apply to the case.

  • If Overwrite Existing Reports is selected, the system updates the existing scheduled reports with the new data entered. This setting ensures that follow-up numbering is specific to each health authority.

  • If a MedWatch report for the FDA has already been scheduled for this case, that report would then be updated with the new information entered.

  • If Create as Follow-up is selected, the system uses the new data to create new reports marked as follow-up reports. This setting ensures that the same number would identify a follow-up report worldwide. Users will be unable to submit follow-up reports before one of the following events occur on the initial or previous follow-up report.

Case Locking for People The Administrator has the option of indicating whether cases that are not locked can appear in periodic reports.
  • If Allow Unlocked cases to be included is selected, then a check box on the periodic report configuration dialogs will allow unlocked cases to appear in periodic reports.

  • To prevent unlocked cases from appearing in periodic reports, select Prevent unlocked cases from appearing.

Report On Selecting Diagnoses will only list the events marked as diagnoses plus events not associated with a diagnosis in Regulatory Reports.
  • The Event Assessment section of the case form will only list diagnosis and unrelated events. If there are no diagnoses, all events are listed. You can configure a default setting for selecting the Diagnoses state at a system level.

  • Selecting All Events will always list all events, regardless of their relationship in the Event Assessment section of the case form. The system will take into consideration both events marked as diagnoses and events marked as symptoms when running the regulatory report algorithm.

Diagnosis Default on Event The options are Yes or No
  • Selecting Yes will set the default Events Diagnosis to Yes whenever a new event is entered.

  • Selecting No will set the default Events Diagnosis to No whenever a new event is entered.

Event Assessment On The Event Assessment section of the case form will only list diagnosis and unrelated events. If there are no diagnoses, all events are listed. You can configure a default setting for selecting the Diagnoses state at a system level.
  • Selecting Diagnoses will include in Event Assessment only those events that are associated with a diagnosis or symptoms that are not associated with any of the diagnoses.

  • Selecting All Events will include all events when the Event Assessment is performed.

Prevent Modification to Autonarrative Selecting the Preventing Modification of Autonarrative check box will prevent users from modifying autonarratives.
Case Autonarrative Selecting the Case Autonarrative check box enables the user to generate an Autonarrative based on one of the templates configured by the method described in this topic.

Templates

Clicking the Templates button enables the Administrator to create a new Autonarrative template, modify/copy an existing template, or delete an existing template.

To create a new Autonarrative template

  1. Click the Templates button in the Case Form Configuration dialog to open the Autonarrative Configuration dialog.

  2. Click New to open the Narrative Configuration dialog.

    Surrounding text describes cpnc.gif.

  3. Under Template Name, enter a name for this new template.

  4. Click the Add button at the bottom of the dialog. A new row for entering a phrase and its associated logic will appear.

  5. Enter a text phrase in the Phrase field. The text can include placeholders that will be substituted by the appropriate case data when the Autonarrative is generated.

    For example, you might enter a phrase such as "The patient was [age] at the onset of this event." When the Autonarrative is being generated, the system substitutes the age placeholder for the actual age of the patient.

  6. Click the ellipsis button to the right of the Logic column. Select or enter an Advanced Condition for the logic section.

    This search will be used to determine whether or not the corresponding phrase will appear in a narrative for a particular case. For example, an advanced condition can be specified so that only cases involving children younger than five years old will contain the phrase "The patient was [age] at the onset of this event" in the Autonarrative.

  7. Repeat steps 4 through 6 to add other text phrases to the template. Click OK to save the template or Cancel to exit the dialog without saving the changes.

    Note:

    Selecting the Preventing Modification of Autonarrative checkbox in the Case Form Configuration dialog will prevent users from modifying autonarratives.
Creating a Template in Another Language

The system enables you to create a template in another language.

To create a template in another language

  1. Once a template is created, double-click the "Narrative Templates" folder to expand the template tree in the Autonarrative Configuration dialog.

    Tip:

    To open the Autonarrrative Configuration dialog, click the Autonarrative button in the Case Form Configuration dialog.
  2. Expand the selected template folder to display the languages for this template. To configure this template in a language other than English, double-click the appropriate language icon.

  3. Configure the foreign language template as described in steps 4 through 7 of the procedure for creating the Autonarrative template above.

  4. Click Close to exit the Autonarrative Configuration dialog.

    Note:

    Autonarrative placeholders in a language other than English will get substituted by text from that particular language. If no text is available in that language, English language text will be used to substitute the placeholders.
Copying a Template to Another Language

The system enables you to copy a template to another language.

To copy a template to another language

  1. Select the original language from which the target language copy is to be created. The original language can be selected in the tree-view of the Autonarrative Configuration dialog.

    Tip:

    To open the Autonarrrative Configuration dialog, click the Autonarrative button in the Case Form Configuration dialog.
  2. Click Copy. The Autonarrative Copy dialog will appear.

    Note:

    In the Autonarrative Configuration dialog, the Copy button for a selected language template will only be available if a template has already been created in that language.
  3. Select the language to which the narrative template is to be copied and click Copy.

  4. The contents of the original language template will now be copied into the selected language template.

Deleting Templates

The system permits you to delete templates.

To delete a language template

  1. Select the appropriate language icon for the template in the Autonarrative Configuration dialog and click Delete.

  2. Select the template folder icon in the Autonarrative Configuration dialog and click Delete.

Duration Calculations

The following table lists and describes the fields associated with this section.

Field/Control Name Description
Event The Duration Calculations section is used to indicate whether the system should calculate event duration (the time from Event Onset Date to Event Stop Date) in an inclusive or an exclusive manner.

For instance, select Inclusive to calculate a range from 01 January to 10 January as ten days. Select Exclusive to calculate a range from 01 January to 10 January as nine days.

If the user has entered both the date and time, the exclusive/inclusive designation is ignored.

Drug The Drug Duration Calculations section is used to indicate whether the system should calculate drug duration in an inclusive manner or an exclusive manner, as described under Event Duration Calculations.

Documentum Common Login

The Documentum Common Login information is used to connect to the Documentum server to perform Documentum related activities to the case form. The system uses this information only if the common profile switch to use the common login is set. This option is only available if the system is configured to use Documentum.

The following table lists and describes the fields associated with this section.

Field/Control Name Description
Username This is the username associated with the Documentum Common Login.
Password This is the password associated with the Documentum Common Login username.

Custom Routines

The following table lists the Field Descriptions associated with this section.

Field/Control Name Description
Custom Routine Before Save The function behaves the same way as the Custom Routine Before Commit. The case ID is passed as a parameter to the function. The return value is a string format. If a null string is returned, the system assumes the procedure executed without any error, and continues with the case save operation. If any numeric/string value is returned, the case save routine is aborted and the system displays the returned string as an error message to the user.
Custom Routine Before Commit This is the Custom routine to be called before case save. Ensure that the custom routine is present in the database, and the application has access to it.
Custom Routine After Commit This is the after-save Custom routine to be called after case save. Ensure that the custom routine is present in the database, and the application has access to it.

Select the Table Config button to select the tables that are being modified in the post-save script.

Custom Routine Before Lock This is the Custom routine to be called before case lock Ensure that the custom routine is present in the database, and the application has access to it.
Attachment File Size Limit (in Megabytes) The file size entered in this field enables you to specify the maximum size limit for attaching a file. The upload limit defined here can be seen in the Attachments and References section of the Bookin screen. The maximum limit for uploading an attachment is 4 GB.

Table Config Button

The Table Config button enables you to fetch only the delta table data after post-save, so that the entire case is not reloaded. This button is enabled only when the Custom Routine After Commit checkbox is selected.

To remove case tables

  1. Select the Custom Routine After Commit checkbox and click the TableConfig button. The following screen appears.

    Surrounding text describes cpcfc.gif.

    Initially, all case tables open under the Available Tables list box.

  2. Select the required table(s) and click Add>> to include them to the Selected Tables list.

    Alternatively, you can select the required table(s) and click <<Remove to exclude them from the Selected Tables list.

  3. Click Cancel to close the screen without making any changes or click Save to save this configuration.

    • The Case Save routine gets modified to retrieve only the table data from the Selected Tables in the configuration.

    • If no Post Save is configured, the Case Save does not execute the Case Load routine.

Modify Data Lock Point

This section displays only if the DLP_USE_LAST_COMPLETED_VERSION switch is in the database schema in the CMN_Profile table.

Surrounding text describes dlp.gif.

The following table lists and describes the fields in this section.

Field/Control Name Description
Use Last Completed Version Enables you to use the last completed version.
Use Next Completed Version (Includes Data Cleaning) Enables you to use the next completed version that includes data cleaning.

To configure case form options

  1. Select the options for Auto Encoding, Dictionary and Central Encoding.

  2. Select the required options for Duration Calculations.

  3. Enter the Documentum Common Login information.

  4. Select and enter the Custom Routine information.

  5. Select the required options for Modify Data Lock Point, if applicable.

  6. Enter the Automation information.

  7. Add New to select the Case Autonarrative information.

  8. Click Save to save the changes made to this section.

Configuring Custom HTTP Header

The system enables you to attach a Custom SMTP Header along with the preconfigured text as the Header for every e-mail it sends.

Surrounding text describes smtp.gif.

  • The Custom SMTP Header text is enabled only when the Custom SMTP Header check box is checked.

    • The user can define the Header and the Header text in the Custom SMTP Header configuration by separating them with a colon (:).

    • The system does not validate the value for the Custom SMTP Header text.

  • You can enter a maximum of 255 characters.

  • All e-mail messages sent using the following processes are sent as Confidential:

    • AG Service: Bulk Transmit Email

    • AG Service: General Email

    • ESM Service: Business / User / IT Email

  • The Audit Log tracks updates to this field.

Configuring Case Processing

This section enables you to configure the case processing fields and items. Select System Configuration --> System Management to view the Common Profile Configuration screen

Tip: The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders.

Each folder contains all the field labels associated with that section.


To view the list of field names associated with the Case Processing section, click the Case Processing folder in the left panel.

The field names associated with Case Processing Configuration appear in the right panel.

Surrounding text describes cpcp.gif.

The Case Processing folder has been further categorized into the following sub-folders:

  • Configuring Assessments

  • Configuring Auto Archiving

  • Configuring Case Numbering

  • Configuring MedDRA Browser

  • Configuring Performance

Field Descriptions

The following table lists the fields available under Case Processing Configuration:

Field/Control Name Description
Create follow-up on unblinding The available options are Yes and No.
Allow User to regenerate reports The available options are Yes and No.
Manually Schedule reports The available options are:
  • Report scheduling will schedule follow up reports

  • Report scheduling will not schedule follow up reports

Events to Display on Assessment Tab The available options are:
  • Event Assessment will display all Events

  • Event Assessment will display Diagnosis Events only

Access on Patient Information The available options are:
  • Initials part of Patient information access group

  • Initials part of Personal Patient Information access group

Search product on Case Form The available options are:
  • Product Name product lookup. Based on products configured in the system.

  • Trade Name product lookup. Based on the licenses configured in the system.

Select Type of WHO drug search for auto drug encoding The available options are:
  • Default WHO schema

  • Use alternate who tables

Action Item Code when QC info is entered The available action item codes are listed in the drop-down list box.
Default Network directory for scanned images Enter the path of the default network directory of scanned images in this text box.

When the user selects New Case from Image from the Quick Launch toolbar, the Windows Open dialog opens, and displays the path specified in this text box, by default.

Uploading Letter after generation Select Auto Upload Letter (enabling Active X) to upload letters automatically through the Active X control. The Active X control supports Microsoft Office XP, Microsoft Office 2003, and Microsoft Office 2007.

Select Manually upload letter to manually upload a letter saved on the local machine.


To configure case processing options

  1. Select the required option in Create follow-up on unblinding.

  2. Select the required option in Allow User to regenerate reports.

  3. Select the required option in Manually Schedule reports.

  4. Select the required option in Events to Display on Assessment Tab.

  5. Select the required option in Access on Patient Information.

  6. Select the required option in Search product on Case Form.

  7. Select the required option in Select Type of WHO drug search for auto drug encoding.

  8. Select the required action item code from the drop-down list box in Action Item Code when QC info is entered.

  9. Enter the path of the default network directory of scanned images in the Default Network directory for scanned images text box.

  10. Select whether to upload letters automatically or manually by making the required selection under Uploading Letter after generation.

  11. Click Save to save the changes made to this section.

Configuring Assessments

This screen enables you to configure the case processing fields and items for assessments. Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To view the list of field names associated with the Case Processing --> Assessments section, click the Assessments folder in the left panel.

The field names associated with Assessments Configuration appear in the right panel.

Surrounding text describes assessments.gif.

Field Descriptions

The following table lists the fields available under Assessments Configuration:

Field/Control Name Description
Display warning when Case Level Assessment does not match with Event Level Assessment The available options are Yes and No.
Criteria for case level causality assessment The available options are:
  • Derive the case level causality based on the As Determined event level causality.

  • Manually select case level causality.

Criteria for case level Seriousness determination The available options are:
  • Derive the case level seriousness based on the events. If any event is serious, case level will be serious.

  • Manually select case level seriousness.

SUSAR Criteria Enables you to enter an SUSAR criteria as an SQL query.

An SUSAR is identified as a Serious, Unexpected, Related Case.

Note: The SQL should not exceed 2000 characters.


To configure case processing options

  1. Select the required option for Display warning when Case Level Assessment does not match with Event Level Assessment.

  2. Select the required option for Criteria for case level causality assessment.

  3. Select the required option for Criteria for case level Seriousness determination.

  4. Enter the SUSAR Criteria.

  5. Click Save to save the changes made.

Configuring Auto Archiving

This screen enables you to configure the auto-archiving. Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

The default rule requires that the following options must be completed before a case is auto-archived:

  • All Action Items Closed

  • All Reports Submitted or Marked required for Non-Submission

  • All Events are encoded

  • All Letters are sent

  • All Cases are locked

Apart from this default rule, you can also configure additional rules/criteria for auto-archiving cases from this screen.

  • Workflow State (Configurable by the user) - This option enables you to select Workflow States. Cases that fall in the specified workflow states can be auto-archived.

  • Advanced Conditions selection (Configurable by the user) - This option enables you to specify advanced conditions. Cases that meet the specified advanced conditions, can be auto-archived.

This feature enables you to define rules for automatically archiving those cases that meet the defined rules.

To view the list of field names associated with the Case Processing --> Auto Archiving section, click the Auto Archiving folder in the left panel.

The field names associated with Auto Archiving Configuration appear in the right panel.

Surrounding text describes autoarchive.gif.

Field Descriptions

The following table lists the fields available under Auto Archiving Configuration:

Field/Control Name Description
Workflow States The Select button enables you to select workflow states from a list of workflow states. The selected workflow states are displayed in the text box.

Cases that belong to these workflow states are marked to be auto-archived.

Advanced Condition Enables you to specify advanced conditions for auto-archiving cases. Cases that meet the advanced conditions are marked to be auto-archived.

Refer to Advanced Conditions for details on creating advanced conditions.

Case Archiving Comment Enables you to enter a pre-defined case close comment, of up to 200 characters. The information entered in this field is displayed in the Case Routing and Case Archive notes.
Execution Period (in Days) Enables you to define how often the cases will be archived.

Note: You can enter up to 99 days only.

If no value is entered, the cases will not be auto-archived.


To configure auto archiving options

  1. Select the workflow states for auto-archiving cases from Workflow States.

  2. Create the advanced conditions for archiving cases in Advanced Condition.

  3. Enter the Case Archiving Comment as a pre-defined case close comment.

  4. Enter how often the cases will be archived, as per number of days, under Execution Period.

  5. Click Save to save the changes made.

Configuring Case Numbering

This screen enables you to configure the case processing fields and items for case numbering. Select System Configuration --> System Management to view the Common Profile Configuration screen

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To view the list of field names associated with the Case Processing --> Case Numbering section, click the Case Numbering folder in the left panel. The field names associated with Case Numbering appear in the right panel.

Surrounding text describes casenumbering.gif.

Field Descriptions

The following table lists the fields available under Case Numbering Configuration:

Field/Control Name Description
Date to use for numbering year placeholder The available options are:
  • Use initial receipt date of the case entered for the automatic system numbering.

  • Use date on the local machine for the automatic system numbering.


To configure case numbering options

  1. Select the required option for Date to use for numbering year placeholder.

  2. Click Save to save the changes made.

Configuring Lot Number

A common profile switch determines whether a user can override an un-validated lot number and enter them in the case form.

Surrounding text describes lotnumber.gif.

Yes is the default. This enables the user to select the options for the Lot Number Validation as current functionality This message box displays the following message:

No matching lot number was found.

If centralized lot search is used, the system hides the Lookup button since a list is automatically returned and displayed.

  • No: The system does not permit the user to keep the existing value. The user can only obtain it from a Look up dialog that lists the available Lot Numbers.

  • The system hides the Keep button.

    A common profile switch determines whether lot validation uses Argus or a centralized lot validation.

    • No (default): This enables the user to select the options for the Lot Number Validation as current functionality from within the Argus Product Families Lot Numbers

    • Yes: This enables the system to query outside the Argus Safety system through a web service return the following parameters for Lot Number Validation

      • Argus sends the user-entered lot number to central system for validation/look-up and retrieves a response to act on.

      • The message format for the retrieved lot is as follows:

    <Lots>

    <Lot>

    <Lot Number>: Lot number

    <Expiration>: Lot expiration date

    <Custom name=name metadata=text>: Custom data to a lot number

  • If more than one lot number is returned, the system displays a lot selection dialog.

The Custom Node

  • The metadata attribute is as labels in the selection dialog that displays the data. The name attribute is used to identify the case form field to be populated with the data in the node.

  • Clients can use an XSLT document to map the custom data to case fields present on the active case form page.

Surrounding text describes lotlook.gif.

If an error occurs during the web service transaction, a message box will appear with the proper error message.

Configuring MedDRA Browser

This screen enables you to configure the case processing fields and items for MedDRA Browser.

Select System Configuration --> System Management to view the Common Profile Configuration screen

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.
  • The existing MedDRA browser category has been renamed Dictionary Browser.

  • A switch in Argus enables the customer to use either local MedDRA Coding or Central System MedDRA Coding (Web Service Method)

    • Local (Default): Current functionality of MedDRA browser using Local Dictionary within the Database

    • Web Services: Returns the MedDRA hierarchy via the configured Web Services.

This enables the User Local MedDRA if term is not found by Web Service" function.

Surrounding text describes dictbrow.gif.

To view the list of field names associated with the Case Processing --> MedDRA Browser section, click the MedDRA Browser folder in the left panel. The field names associated with MedDRA Browser are in the right panel.

Field Descriptions

The following table lists the fields available under MedDRA Browser Configuration:

Field/Control Name Description
Term Selection in MedDRA Browser The available options are:
  • Select any term to code if multiple are returned for the search

  • Select the Primary SOC term for encoding if multiple terms are returned from the search.


To configure the MedDRA browser

  1. Select the required option for Date to use for numbering year placeholder.

  2. Click Save to save the changes made.

Configuring WHO Drug

Argus supports WHO-Drug encoding using a locally installed version of the WHO-Drug dictionary through the WHO-Drug browser.

  • A switch in Argus enables you to use either local WHO-Drug Coding or Central System WHO-Drug Coding (Web Service Method) under the Dictionary browser category

    • Local (Default): Uses the current functionality of WHO-Drug browser that uses the Local Dictionary in the Database

    • Web Service: Returns the WHO-Drug fields via the configured Web Services

    • The system enables the User Local MedDRA if term is not found by Web Service"

Configuring Performance

This screen enables you to configure the case processing fields and items for performance.

Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To view the list of field names associated with the Case Processing --> Performance section, click the Performance folder in the left panel. The field names associated with Performance appear in the right panel.

Surrounding text describes configsperf.gif.

Field Descriptions

The following table lists and describes the fields available under Performance Configuration:

Field/Control Name Description
When to process field level validation Enables you to configure the frequency of field level validation. Select Only on case save to validate only when a case is saved.

Alternatively, select Every page update to validate fields whenever a page is updated.

Where to store temporary case information during data entry Enables you to select the location where you can save the temporary case information during data entry.

You can choose On the database in web case table or On the fileserver cache directory.

Use Oracle Text for duplicate search querying Enables you to select Oracle Text for duplicate search querying. Click Yes to enable this feature.
Refresh Oracle Text Index interval (in Minutes) Enables you to configure the interval (in minutes) between each refresh of an Oracle Text Index.

This feature is useful while searching for duplicate cases. It is advisable to enter a high interval for low number of cases and vice versa.

Start Time for Oracle Text Refresh Enables you to specify the time when the Oracle text will be refreshed.

To configure performance

  1. Select the required option for When to process field level validation, as applicable.

  2. Select the required option for Where to store temporary case information during data entry, as applicable.

  3. Select the required option for Use Oracle Text for duplicate search querying, as applicable.

  4. Enter the time difference between each refresh (in minutes), under Refresh Oracle Text Index interval (in Minutes).

  5. Enter the time (in military format) when the Oracle text refresh will begin, under Start Time for Oracle Text Refresh.

  6. Click Save to save the changes made.

Configuring Documentum

The system enables you to configure to choose Document Management from the Common Profile Switches: Document Management

Surrounding text describes documentum.gif.

  • The system enables the user to select from the following:

    • External System: The system populates this drop-down with the supported external interfaces. Currently, selecting this radio button enables the drop-down. In this release, the drop-down list has only one option, Documentum 6.5"

    • Argus: Selecting this option shall create the documents described below within the Argus Safety database. When selected, the drop-down for the External System is disabled.

    • The Cabinet Name contains length shall be 255 characters

    • The Repository Type length shall be 255 characters

  • The Documentum Login has been removed from the Case Form Configuration and placed in the Document Management dialog.

    • The system enables the user to enter the User name and the Password while using a Central user for Document Storage System.

    • The system enables the Document Common Login when the user selects User Documentum Login/Password".

    • The system encrypts the Password in the DB (128 bit) in Audit Log

  • Docbase and Domain are text box fields. The field can be a maximum of 255 characters.

  • The system enables the user to configure the following for Document Management:

    • E2B Reports

    • Expedited Paper Reports

    • Periodic Reports

    • Attachments saved within the cases

    • E2B Reports:

  • If the E2B switch is enabled and the user transmits an E2B Report (Before submission to the Gateway), the system stores the E2B XML Message in Documentum.

  • When the Report Submission is successful and the report is marked as submitted in Argus, the system updates a flag in the Documentum database to designate the same.

  • Expedited Reports

    • If the Expedited switch is enabled and the user submits an expedited report, the Argus Safety Service inserts the report into Documentum as a PDF file.

    • When the Report Submission is successful and the report is marked as submitted, the system updates a flag in the Documentum database to signify the same.

  • Periodic Reports:

    • If the Periodic Switch is enabled and a Periodic Report is approved in Argus, an Argus Safety Service exports the report as a PDF file and saves it in the Documentum database.

    • When the Report Submission is successful and the report is marked submitted, the system updates a flag in the Documentum database to indicate the same.

  • Attachments:

    • When this switch is enabled, a new button is available on the Argus Attachments screen, LAM Attachments Section label Attach Documentum Link".

    • The Argus Bookin dialog has an additional drop down option for attaching to Documentum.

    • When the Links Switch is enabled, the system stores all Argus Attachments in the Documentum database.

    • Clicking the Attach Documentum Link button opens a search dialog to enable the user to search the Documentum database for a document. This document will then be linked as a attachment within Argus.

      Surrounding text describes dl.gif.

    • When the user clicks the Attach Documentum Link button, the following occurs:

    • The system presents a search dialog to enable the user to search for a document in the Documentum database.

    • The user must select a Table to Search. This list is a distinct Table List from the Documentum_table_info Table.

    • After the user selects a Table, the system populates the Column drop down with all the columns available for that table based on configuration from the same table.

    • When the user selects the Full Search option, the system performs a like search in Documentum.

  • If LDAP is enabled, the system automatically send the login information from Argus to Documentum.

  • After selecting a document from the Search results, the system saves the URL for the Argus attachment.

  • If the user clicks the URL, Argus automatically opens the document from Documentum.

  • Argus refers to two (2) that enables the customer to specify which tables/columns can be searched in Documentum and which Table Fields to display in the Search Results.

    • documentum_table_info - This table holds the table / fields the user will be able to search.

      Type_Name - Table to Search

      Attribute_Name - Field in the Table to Search

      Attribute_Type - Type of field being searched.

    • Documentum_display_info - This table stores the Return Search Parameters.

      Type_Name - Table to Search

      Attribute_Name - Field in the Table to Search

      Sort_Id - The order in which the fields will be displayed

    • The Document Management (Central or Documentum) database gets a new document each time a document attachment is added as a new attachment. Existing documents are modified for changes.

    • The system does not create a new document in the Document Management (Central or Documentum) database each time a case /event is saved in Argus or Affiliate

    • When cases are copied, the document copy has the same DOC ID (Object ID) as the original case. If the Document is modified after the cases are copied, the system gets a new DOC ID only for the case attachments that were modified.

    • The icon is similar to the Additional Info requirements for attachment types

    • When the user clicks the attachment to open it, the system retrieves the attachment from Documentum

    • When events from the Affiliate are accepted in Argus as Argus cases, the system keeps the DOC ID (Object ID) from the Affiliate Event

    • Attachments can be entered to the case / affiliate event via

      Affiliate Events

      Bookin in Argus or Affiliate

      Case Form / Affiliate Event Form

      Intake WL

  • Error Messages

    • If the system cannot connect to the document system, it displays the following message:

      Argus was unable to connect to the document management system. Please contact your Administrator for more details.

    • If the document system does not return any rows, the system returns a dialog with the following message

      No documents returned.

    • Select System Configuration --> System Management to view the Common Profile Configuration screen

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To view the list of field names associated with the Case Processing --> Documentum section, click the Documentum folder in the left panel. The field names associated with Documentum appear in the right panel.

Field Descriptions

The following table lists the fields available under Documentum Management:

Section Field Description
Common Login Use Common Login Password Users use a common login password to access the system
Use Logged in User's Username/Password
  • Users login using their system user names and password.
  • This is the default.

Docbase The name of the document database.
Domain The name of the domain where the database resides.
Enable Storage of E2B Reports in Documentum Repository Documentum Enables the system to store E2B reports in the Documentum document repository.

This is the default.

Argus Enables the system to store E2B reports in the Argus document repository.
Cabinet Name The storage location of the E2B reports.
Enable Storage of submitted expedited reports in Document Repository Documentum Enables the system to store submitted expedited reports in the Documentum document repository.

This is the default

Argus Enables the system to store submitted expedited reports in the Argus document repository.
Cabinet Name The storage location of the submitted expedited reports.
Enable storage of case attachment files in the Document Repository Documentum Enables the system to store case attachment files in the Documentum document repository.

This is the default

Argus Enables the system to store case attachment files in the Argus document repository.
Cabinet Name The storage location of the case attachment files.
Document Type The type of document that is being stored.
Enable storage of submitted periodic reports in the Document Repository Documentum Enables the system to store submitted periodic reports in the Documentum document repository

This is the default

Argus Enables the system to store submitted periodic reports in the Argus document repository.
Cabinet Name The storage location of the submitted periodic reports.

To configure Documentum

  1. Select the Documentum Login to configure the login for the user.

  2. Select the option for Enable Storage of E2B Reports in Documentum.

  3. Select the option for Enable Storage of submitted expedited reports in Documentum.

  4. Select the option for Enable storage of case attachment files in Documentum and additionally the searching and attaching files already existing in Documentum to a case.

  5. Select the option for Enable storage of submitted periodic reports in Documentum.

  6. Click Save to save the changes made.

Configuring E2B

This screen enables you to configure the E2B fields and items for E2B. Select System Configuration --> System Management to view the Common Profile Configuration screen

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To view the list of field names associated with the Case Processing --> E2B section, click the E2B folder in the left panel. The field names associated with E2B appear in the right panel.

Surrounding text describes e2b.gif.

Field Descriptions

The following table lists the fields available under E2B:

Field/Control Name Description
Onset Date Calculation This field enables the user to configure if the onset date is to be calculated based on any suspect drug or on the primary suspect drug only.
Drug assessment method (used by E2B/ESM module) This field enables the user to incorporate the drug assessment method used by E2B/ESM module.
Blind status during E2B report generation The available options are:
  • Blinded

  • Unblinded

Perform length check of Argus fields against E2B standard The available options are:
  • Yes

  • No

Default viewing format of the E2B report (used with Electronic Submission Module (ESM)) The available options are:
  • SGML

  • CIOMS

  • MEDWATCH

  • DECODED VIEW

Default DTD This field enables the user to select the Default DTD from the drop-down list box.
Send E2B Nullification Report This field enables the user to configure whether to send the E2B nullification report or not.
Auto Accept Notes Enables the user to enter notes (up to 190 characters). It is required for these notes to be entered for the acceptance of the E2B. The notes entered here, are automatically provided during E2B acceptance.

To configure E2B

  1. Enable the check-box option for Drug assessment method (used by E2B/ESM module), if required.

  2. Select the option for Blind status during E2B report generation.

  3. Select the option for Perform length check of Argus fields against E2B standard.

  4. Select the option for Default viewing format of the E2B report (used with Electronic Submission Module (ESM)).

  5. Select the option for Default DTD.

  6. Select the required radio button under Onset Date Calculation, as applicable.

  7. Select whether to send the nullification report in Send E2B Nullification Report.

  8. Enter the comments for the automatically generated notes, when an E2B is accepted, under Auto Accept Notes.

  9. Click Save to save the changes made to this screen.

Local Labeling

This section enables you to configure the common profile switches for Local Labeling and includes discussions of the following:

  • Configuring Local Labeling

  • Configuring Local Labeling LAM

Configuring Local Labeling

The Local Labeling Configuration screen enables you to modify the options available through local labeling. Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the fields associated with the Local Labeling section, click the Local Labeling folder in the left panel. The configurable fields associated with Local Labeling appear in the right panel.

Surrounding text describes ll.gif.

Field Descriptions

The following table lists and describes the fields available under Local Labeling:

Field/Control Name Description
Number of Cases returned in local labeling dialog: default X This field enables the user to configure the number of cases that are returned in the local labeling dialog.

Example: If the value is entered as 20 then 20 cases are returned in the local labeling dialog.

Action to be taken after timeout The available options are:
  • Discard

  • Submit

Timeout for assessment data lock (in minutes) This field enables the user to enter the minutes after which the time-out for assessment data lock is applicable.

To configure local labeling

  1. Enter the number in Number of Cases returned in local labeling dialog: default.

  2. Select the option for Action to be taken after timeout.

  3. Enter the value in minutes for Timeout for assessment data lock (in minutes).

  4. Click Save to save the changes made.

Configuring LAM

The Local Labeling LAM Configuration screen enables you to modify the options available through local labeling for LAM.

Field Label Updates

The Argus Console Field Labels option enables the user to modify the field labels for the Argus Affiliate Event Information form.

  • The existing Argus fields are under the Argus Safety folder structure.

  • Please refer to the tables in the LAM Information section for the details about the Help Text for the fields.

  • The system enables the user to hide the field on the LAM form.

  • The system prints the Affiliate field labels.

  • The system tracks all field label updates in the audit log.

Field Validation Updates

Argus Affiliate enables the user to configure Field Validations for Mandatory and Warning for the LAM Event fields.

  • The existing Argus fields are under the Argus Safety folder structure.

  • Please refer to the table for LAM Event Info for the fields in the Field Validations.

  • The Affiliate fields for advanced conditions are only visible for field validations. They are not visible to the rest of the application.

  • The system prints the information for the configured field validations.

  • The system tracks all updates to field validations in the audit log.

  • The system displays the standard Justifications dialog to enable the user to enter the justifications for overriding the warnings, but does not permit the user to save the case for a mandatory error.

Select System Configuration --> System Management to view the Common Profile Configuration screen

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the fields associated with the Local Labeling LAM section, click the Local Labeling folder in the left panel.

  • The LAM sub-folder is displayed in the left panel.

  • Click on LAM sub-folder to configure the LAM options.

  • The configurable fields associated with Local Labeling Lam appear in the right panel.

Surrounding text describes lllam.gif.

Field Descriptions

The following table lists and describes the fields available under Local Labeling LAM:

Field/Control Name Description
Allow hiding of the Local Labeling dialog from Users The available options are:
  • Local Labeling will be visible to users

  • Local Labeling will be hidden from users

Report Scheduling when Labeling Changes from the Local Labeling Screen The available options are:
  • No Report Scheduling will not be executed when the Local Labeling is changed

  • Report Scheduling will occur for those Licenses where the Labeling has changed

Re-evaluate all scheduled and generated reports related to a case when the labeling is changed from the Local Labeling dialog. The available options are:
  • The system will not re-evaluate generated reports

  • Re-evaluate general reports.


To configure local labeling for LAM

  1. Select the option for Allow hiding of the Local Labeling dialog from Users.

  2. Select the option for Report Scheduling when Labeling Changes from the Local Labeling Screen.

  3. Select the option for Re-evaluate all scheduled and generated reports related to a case when the labeling is changed from the Local Labeling dialog.

  4. Click Save to save the changes made.

Configuring MedWatch

The MedWatch Configuration screen enables you to modify the customizable fields on the MedWatch form. Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To view the list of field names associated with the MedWatch Configuration section, click the MedWatch Configuration folder in the left panel.

Surrounding text describes medwatch.gif.

The field names associated with MedWatch Configuration appear in the right panel.

Field Descriptions

The following table lists and describes the fields available under MedWatch Configuration:

Field/Control Name Description
Firm Name as it Should Appear at the Top of Each Page Enables the user to enter the name of the reporting firm on the MedWatch form.
Date of FDA Approval to appear on the first page Enables the user to enter the FDA approval date of the manufacturer.
Disclaimer to appear at the bottom of the first page Enables the user to enter a brief disclaimer.
Default text to appear on Block H10 Enables the user to enter default text.
Reset MedWatch Numbering Enables the user to reset the sequence number that appears on the MedWatch form for the manufacturer.
Mfr. Site FDA Number Displays the FDA number for the Manufacturer Site which submitted the MedWatch 3500 Device report in the year.
Year Displays the year of report submission.
# of Reports Displays the number of submitted reports for products associated with a Manufacturing Site in that year
Reset Number Enables the user to reset the Sequence Number.

To configure the MedWatch form options

  1. Enter the Firm Name as it Should Appear at the Top of Each Page.

  2. Enter the Date of FDA Approval to appear on the first page.

  3. Enter the Disclaimer to appear at the bottom of the first page.

  4. Enter the Default text to appear on Block H10.

  5. Click Reset MedWatch Numbering to reset the sequence number that appears on the MedWatch form, for the manufacturer as required.

Reporting Configuration

This section enables you to configure the common profile switches for Reporting. This topic has been divided into the following sub-topics:

Section Sub-Section Description
Reporting Expedited Reports Configuration The Expedited Reporting Configuration screen enables you to modify the options available for expedited reporting.
Expedited BfArM The Expedited BfArM Reporting Configuration screen enables you to modify the options available for expedited BfArM reporting.
Expedited Canada The Expedited Canada Reporting Configuration screen enables you to modify the options available for expedited Canada reporting.
Expedited CIOMS The Expedited CIOMS Reporting Configuration screen enables you to print fields such as Patient ID, Medically Confirmed and Worldwide Number in the "26. REMARKS" section of the CIOMS form.
Expedited MedWatch The Expedited MedWatch Reporting Configuration screen enables you to modify the options available for expedited MedWatch reporting.
Periodic The Periodic Reporting Configuration screen enables you to modify the options available for periodic reporting.
Scheduling The Scheduling Reports Configuration screen enables you to modify the options available for scheduling reporting.

Configuring Reporting

The Reporting Configuration screen enables you to modify the options available for reporting. Select System Configuration --> System Management to view the Common Profile Configuration screen

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the fields associated with the Reporting section, click the Reporting folder in the left panel. The configurable fields associated with Reporting appear in the right panel.

Surrounding text describes reportings.gif.

Field Descriptions

The following table lists the fields available under Reporting:

Field/Control Name Description
Determine the minimum length of the routing comment text length on report routing dialog The available options are:
  • No routing comment will be required

  • Minimum length of text required


To configure reporting

  1. Select the option for Determine the minimum length of the routing comment text length on report routing dialog.

  2. Enter the numeric value in the Minimum length of text required text-box, if applicable.

  3. Click Save to save the changes made to this screen.

Expedited Reports Configuration

The Expedited Reporting Configuration screen enables you to modify the options available for expedited reporting. When configuring expedited reporting rules, be aware of the following:

  • If the user does not have permission to access Advanced Conditions on the Expedited Reporting Rules, the system does the following:

    • Displays the advanced condition name instead of displaying a blank.

    • Does not permit the user to modify or view advanced condition details.

    • Disables the Adv Condition button.

  • The system enables the user configure the Blinding Study Products option for those included in the case (default unchecked).

    • The system track updates to this field in the audit log.

    • The Reporting Rules reports print the new options

  • For cases where expedited reports are due, the user can force-distribute expedited reports even if processing is incomplete.

  • The reporting rules have a Forced Distribute XXX days before due check box. The default is unchecked.

    • If the user checks the Force Distribute option, the # of days before due field is entered and automatically checks the Auto Distribute check box on the reporting rule (grayed out).

    • The user can enter the number of days from 0 - # of days defined within the time frame.

    • If the user enters a value greater than the defined time frame, the system displays the following message:

    • Please enter a value less than the Time Frame defined for the Reporting Rule.

    • If the user has not checked Force Distribute, the system disables the days before due.

  • The system tracks updates made to the new Argus Console fields in the audit log.

  • The system prints the new fields on the Reporting Rules report.

Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the fields associated with the Reporting section, click the Reporting folder in the left panel. The Expedited sub-folder opens in the left panel.

Click on Expedited sub-folder to configure the expedited reporting options. The configurable fields associated with Expedited Reporting open in the right panel.

Surrounding text describes ex.gif.

Field Descriptions

The following table lists and describes the fields available under Expedited Reporting:

Field/Control Name Description
Active moiety report scheduling evaluation (a report scheduled against a product/license that shares ingredients with a product in a case) The available options are:
  • Enable

  • Disable (default)

Allows Bulk by Form to show Unlocked Cases for Final Report The available options are:
  • Report by Form and Bulk Report By Case will filter final reports by Locked Cases only

  • Bulk Report By Form and Bulk Report By Case will allow selection of unlocked cases to be submitted as Final

License number on MedWatch Drug Report The available options are:
  • Print License # only for the scheduled license on MedWatch Drug Report

  • Print all available license numbers for Drug as determined by the scheduled license

Default name of Regulatory Agency for New Draft Expedited Reports from Analysis Tab of the Case Form This enables the user to select the Default Name of the Regulatory agency from the drop-down list.
Text to display as comment when a downgrade report is scheduled This enables the user to enter the text to display when a downgrade report is scheduled.
CIOMS report format to use The available options are:
  • Standard

  • Custom

CIOMS Form Selection This enables the user to select the CIOMS form to be used across the application for Expedited Reporting / Periodic Reporting.
Auto Distribution Transmission Comments Enables the user to enter transmission comments of up to 2000 characters, for Expedited Reports Transmission.

These comments are auto-distributed, based on Expedited Reporting Rules or Reporting Destinations.

Auto Distribution Submission Comments Enables the user to enter submission comments of up to 2000 characters, for Expedited Reports Transmission.

These comments are auto-distributed, based on Expedited Reporting Rules or Reporting Destinations.

Print Case Version of Expedited Reports (x.y.z) This switch enables the user to enable or disable the printing of the case version of expedited reports.

To configure expedited reports

  1. Select the option for Active moiety report scheduling evaluation (a report scheduled against a product/license that shares ingredients with a product in a case).

  2. Select the option for enables Bulk by Form to show Unlocked Cases for Final Report.

  3. Select the option for License number on MedWatch Drug Report.

  4. Select the option for Default name of Regulatory Agency for New Draft Expedited Reports from Analysis Tab of the Case Form from the drop-down text-box.

  5. Enter the text in the Text to display as comment when a downgrade report is scheduled text-box, if applicable.

  6. Select the option for CIOMS report format to use.

  7. Select the relevant CIOMS form, from CIOMS Form Selection.

  8. Enter the transmission comments in Auto Distribution Transmission Comments.

  9. Enter the submission comments in Auto Distribution Submission Comments.

  10. Select whether to enable or disable printing the case version of expedited reports in Print Case Version of Expedited Reports (x.y.z).

  11. Click Save to save the changes made to this screen.

Expedited BfArM Reports Configuration

The Expedited BfArM Reporting Configuration screen enables you to modify the options available for expedited BfArM reporting.

Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the fields associated with the Reporting section, click the Reporting folder in the left panel. The Expedited- BfArM sub-folder is displayed in the left panel.

Click on the Expedited-BfArM sub-folder to configure the expedited BfArM reporting options. The configurable fields associated with Expedited - BfArM Reportingappear in the right panel.

Surrounding text describes exbfarm.gif.

Field Descriptions

The following table lists and describes the fields available under Expedited - BfArMReporting:

Field/Control Name Description
Causality Value on BfArM Report The available options are:
  • beh.Azrt

  • Hersteller

  • Arznel.Komm

Value of field "Grunderkrankung" on the BfArM/PEI form The available options are:
  • Do not output suspect and concomitant product indication in this field

  • Output additional suspect and concomitant product indications


Use the following steps to configure the expedited BfArM reports.

  1. Select the option for Causality Value on BfArM Report.

  2. Select the option for Value of field "Grunderkrankung" on the BfArM/PEI form.

  3. Click Save to save the changes made to this screen.

Expedited Canada Reports Configuration

The Expedited Canada Reporting Configuration screen enables you to modify the options available for expedited Canada reporting.

Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the fields associated with the Reporting section, click the Reporting folder in the left panel. The Expedited- Canada sub-folder is displayed in the left panel.

Click on the Expedited-Canada sub-folder to configure the reporting options. The configurable fields associated with Expedited - CanadaReporting appear in the right panel.

Surrounding text describes excan.gif.

Field Descriptions

The following table lists and describes the fields available under Expedited- Canada Reporting:

Field/Control Name Description
SQL used to populate the "Is there an ongoing clinical trial for this drug in Canada" field on the Canadian Expedited ADR report form This field enables the user to enter the associated SQL syntax.
SQL used to populate the "Is there a clinical trial application for this drug under review in Canada" field on the Canadian Expedited ADR report form This field enables the user to enter the associated SQL syntax.
SQL used to populate the "Is there a new drug submission for this drug under review in Canada" field on the Canadian Expedited ADR report form This field enables the user to enter the associated SQL syntax.
SQL used to populate the "Report ADR occurred in Phase I-III Study" field on the Canadian Expedited ADR report form This field enables the user to enter the associated SQL syntax.
SQL used to populate the "Report ADR occurred in Phase I-IV Study" field on the Canadian Expedited ADR report form This field enables the user to enter the associated SQL syntax.

To configure expedited Canada reports

  1. Enter the SQL syntax for SQL used to populate the "Is there an ongoing clinical trial for this drug in Canada" field on the Canadian Expedited ADR report form.

  2. Enter the SQL syntax for SQL used to populate the "Is there a clinical trial application for this drug under review in Canada" field on the Canadian Expedited ADR report form.

  3. Enter the SQL syntax for SQL used to populate the "Is there a new drug submission for this drug under review in Canada" field on the Canadian Expedited ADR report form.

  4. Enter the SQL syntax for SQL used to populate the "Report ADR occurred in Phase I-III Study" field on the Canadian Expedited ADR report form.

  5. Enter the SQL syntax for SQL used to populate the "Report ADR occurred in Phase I-IV Study" field on the Canadian Expedited ADR report form.

  6. Click Save to save the changes made to this screen.

Expedited CIOMS Reports

The Expedited CIOMS Reporting Configuration screen enables you to modify the options available for expedited CIOMS reporting. Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the fields associated with the Reporting section, click the Reporting folder in the left panel.

The Expedited- CIOMS sub-folder is displayed in the left panel. Click on the Expedited-CIOMS sub-folder to configure the expedited CIOMS reporting options.

The configurable fields associated with Expedited - CIOMS Reporting appear in the right panel.

Surrounding text describes excioms.gif.

Field Descriptions

The following table lists the fields available under Expedited- CIOMS Reporting:

Field/Control Name Description
Print Patient ID, Study ID, Center ID in 26. REMARKS section of the CIOMS form Enables the user to print the Patient ID, Study ID and Center ID fields in the &rdquor;26. REMARKS" section of the CIOMS form.
Print Medically Confirmed in the 26. REMARKS section of the CIOMS form Enables the user to print Medically Confirmed in the 26. REMARKS section of the CIOMS form.
Print World Wide Number in the 26. REMARKS" section of the CIOMS form Enables the user to print World Wide Number in the &rdquor;26. REMARKS" section of the CIOMS form.

To configure the expedited CIOMS reports

  1. Select the Print Patient ID, Study ID, Center ID in the &rdquor;26. REMARKS" section of the CIOMS form checkbox to print these fields in the CIOMS form.

  2. Select the Print Medically Confirmed in the &rdquor;26. REMARKS" section of the CIOMS form checkbox to print this field in the CIOMS form.

  3. Select the Print World Wide Number in the &rdquor;26. REMARKS" section of the CIOMS form checkbox to print this field in the CIOMS form.

  4. Click Save to save the changes made to this screen.

Expedited MedWatch Reports Configuration

The Expedited MedWatch Reporting Configuration screen enables you to modify the options available for expedited MedWatch reporting.

Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the fields associated with the Reporting section, click the Reporting folder in the left panel. The Expedited- MedWatch sub-folder is displayed in the left panel.

Click on the Expedited-MedWatch sub-folder to configure the expedited MedWatch reporting options. The configurable fields associated with Expedited MedWatch Reporting appear in the right panel.

Surrounding text describes exmedwatch.gif.

Field Descriptions

The following table lists the fields available under Expedited- MedWatch Reporting:

Field/Control Name Description
Value for Field E4 on MedWatch The available options are:
  • Incidence Country not USA will mark Unknown in E4.

  • Incidence Country not USA will use Sent to Authority field on case form to determine E4 value.

Data to print on follow up MedWatch Device form The available options are:
  • All information (initial + follow-up) is displayed. (Previous Behavior).

  • Only Display changed information from the initial report.

Number from LM_REF_TYPES.REF_TYPE_ID for Reference Type containing Legacy Case Number (to print MedWatch forms) This field enables the user to select the required option from the drop-down list.

To configure expedited MedWatch reports

  1. Select the option for the Value for Field E4 on MedWatch.

  2. Select the option for the Data to print on follow up MedWatch Device form.

  3. Select the required option for Number from LM_REF_TYPES.REF_TYPE_ID for Reference Type containing Legacy Case Number (to print MedWatch forms) from the drop-down list box.

  4. Click Save to save the changes made to this screen.

Periodic Reports Configuration

The Periodic Reporting Configuration screen enables you to modify the options available for periodic reporting.

Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the fields associated with the Reporting section, click the Reporting folder in the left panel. The Periodic sub-folder is displayed in the left panel.

Click on the Periodic sub-folder to configure the periodic reporting options. The configurable fields associated with Periodic Reporting appear in the right panel.

Surrounding text describes per.gif.

Field Descriptions

The following table lists and describes the fields available under Periodic Reporting:

Field/Control Name Description
Inclusion Criteria for cases in the ICH PSUR report The available options are:
  • Use Causality of the primary event

  • Use case level causality

  • Use causality of all the events against products in the PSUR

Print footnote Non Serious Listed for non-serious listed cases in ICH PSUR report The available options are:
  • Yes

  • No

Inclusion criteria of event for a product in the PSUR The available options are:
  • Primary Event (Left Most Diagnosis or the left-most Event if there is no Diagnosis on the case form)

  • Most Severe Event for the Product

  • Case Level Seriousness is used

Determine Possible Causality from the causality score This field enables the user to enter a numeric value.
Determine Probable Causality from causality score This field enables the user to enter a numeric value.
On PSUR, NDA, IND, Medical Review List Reports The available options are:
  • Use Initial Receipt Date for report search date range

  • Do not see initial Receipt Date for report search date range

Inclusion Criteria for case in the ICH PSUR report The available options are:
  • Use listedness of the primary event

  • Use case level listedness

Seriousness Determination for event in the PSUR Enables the user to configure the seriousness determination for an event in the PSUR. The available options are:
  • (Default) Seriousness from either case level or primary event level

  • Product Primary Event Seriousness is used

  • Case Level Seriousness is used


To configure periodic reports

  1. Select the option for Inclusion Criteria for cases in the ICH PSUR report.

  2. Select the option for Print footnote "Non Serious Listed" for non-serious listed cases in ICH PSUR report.

  3. Select the option for Inclusion criteria of event for a product in the PSUR.

  4. Enter the value for Determine Possible Causality from the causality score.

  5. Enter the value for Determine Probable Causality from causality score.

  6. Select the option for On PSUR, NDA, IND, Medical Review List Reports.

  7. Select the option for Inclusion Criteria for case in the ICH PSUR report.

  8. Select the option for Seriousness Determination for event in the PSUR.

  9. Click Save to save the changes made to this screen.

Scheduling Reports Configuration

The Scheduling Reports Configuration screen enables you to modify the options available for scheduling reporting. Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the fields associated with the Reporting section, click the Reporting folder in the left panel. The Scheduling sub-folder is displayed in the left panel.

Click on the Scheduling sub-folder to configure the scheduling report options. The configurable fields associated with Scheduling Reports appear in the right panel.

Surrounding text describes sched.gif.

Field Descriptions

The following table lists and describes the fields available under Schedule Reports:

Field/Control Name Description
Report Scheduling The available options are:
  • Report Scheduling will be run by the Middle Tier Service

  • All report scheduling will be done locally on the client machine

Enable separate scheduling of device reporting rules from drugs and vaccines The available options are:
  • Yes

  • No

Report Scheduling Causality Operand Enables the user to select from the causality operands AND/OR to use for scheduling a report.

To configure scheduling

  1. Select the option for Report Scheduling.

  2. Select the option for Enable separate scheduling of device reporting rules from drugs and vaccines.

  3. Select the operand to use for scheduling a report from Report Scheduling Causality Operand.

  4. Click Save to save the changes made to this screen.

Configuring Security

The Security Configuration screen enables you to modify the options available for security. Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the fields associated with the Security section, click the Common Profile--> Security folder in the left panel. The configurable fields associated with Security appear in the right panel.

Surrounding text describes secu.gif.

Field Descriptions

The following table lists the fields available under Security:

Field/Control Name Description
Number of previous passwords that cannot be repeated Enables you to configure the number of passwords that can be allowed.

For example, if you enter 4 in this field, it configures the system to enable up to 4 previous passwords that cannot be used as passwords again.

Number of non-alpha characters in password Enables you to configure the number of non-alpha characters that should exist in a password. Non-alpha characters include characters such as @, $, etc.

Note: To avoid bad configuration, we recommend that the value of this switch is kept as 0 or 1 only.

Minimum number of characters in the password Enables you to configure the minimum number of characters that a password must have.

For example, if you enter 8 in this field, it configures the system to ensure that every password contains at least 8 characters.

Number of consecutive failed login attempts before account is locked out Enables you to configure the number of consecutive failed login attempts that can be allowed before an account is locked out.

For example, if you enter 3, it means that up to 3 consecutive failed login attempts are allowed. If the fourth consecutive login attempt also fails, the account gets locked out.


To configure security

  1. Enter the value for the number of unique previous passwords in Number of previous passwords that cannot be repeated.

  2. Enter the value for the number of non-alpha characters in Number of non-alpha characters in password.

  3. Enter the value for the minimum number of characters for a password in Minimum number of characters in the password.

  4. Enter the value for the number of consecutive failed login attempts in Number of consecutive failed login attempts before account is locked out.

  5. Click Save to save the configured values.

  6. Click LDAP to configure the LDAP fields.

The configurable fields associated with LDAP appear in the right panel.

Field Descriptions

The following table lists and describes the fields available under LDAP:

Field/Control Name Description
Enable LDAP at system level The available options for this are:
  • Yes

  • No


To configure security

  1. Select the option for Enable LDAP at system level.

  2. Click Yes to enable the LDAP Search Domain Account. This displays the LDAP Search Domain Account dialog.

    Surrounding text describes seculdap.gif.

    The following table describes the fields of the LDAP Search Domain Account dialog:

    Field/Control Name Description
    Use Secure Socket Layer If your LDAP Server is configured to use SSL for communication, please check this box. Use of SSL enables for a Secure communication between the client and the server using secure keys.
    Force Anonymous Binding for Search When setting up the LDAP Server, you have the option to force users to bind (authenticate) to the LDAP Server prior to being able to search the LDAP Tree. If this option has been setup in your LDAP server, this option must be checked.
    UserDN During the setup of the LDAP server, the distinguished name and tree structure is created for users to be configured under. Enter in the defined structure as defined in your LDAP server into this box. This is required only if the server is setup for Force Anonymous Binding for Search".
    Password Enter in the password for the User entered in the UserDN box for the bind to the server.
    Server Name Enter in the LDAP Server name or IP Address to which LDAP Authentication needs to occur on.
    Port Number Enter the port on which the LDAP Authentication Services are enabled on the LDAP Server (Default Value: 389).
    BaseDN Enter in the topmost distinguished name of your tree defined on the LDAP Server for which you would like to search for users under.
    Time Out (Sec) Enter a value in seconds, which will tell Argus how long to wait for a response from the LDAP Server during any authentication before timing out (Default Value: 10).
    LDAP Search Key Enter the key to authenticate the user name against in the LDAP Tree structure. For Example, when using Microsoft Active Directory, to authenticate using the Windows Username (Not Full Name), enter in sAMAccountName.

    • If you select the Use Secure Socket Layer (SSL) checkbox, the Port Number is auto-populated with the value 636.

    • If this checkbox is not selected, the Port Number is auto-populated with the value 389.

    • A generic LDAP server can accept anonymous as well as non anonymous binding, based on the configuration.

    • If the Force anonymous binding for search? checkbox is not selected, both UserDN andPassword are enabled.

  3. Enter the LDAP username and password in the UserDN and Password fields, respectively.

  4. Enter the values for Server Name, Port Number, Base DN, Time Out and LDAP Search Key, as required.

    • The field length for Port Number and Time Out is 5 characters, while the Server Name, BaseDN, LDAP Search Key, UserDN and Password can be up to 255 characters.

  5. Click Save to save the changes made to this screen.

Configuring Single Sign-on

A common profile switch determines whether the system uses the single sign on function. The Enable Single Sign-on checkbox, enables you to configure the system to use the single sign-on feature.

Before enabling the single sign-on feature, be aware of the following:

  • If the user enables the Single Sign on feature, the user must enter Single Sign on the HTTP Header element Argus application uses for authentication.

    • This field can contain a maximum of 40 characters

    • If the single sign on feature is enabled and the user does not enter the Single Sign On HTTP Header, the system displays the following error message:

  • Please enter the Single Sign on HTTP Header or disable the Single Sign on feature.

The following table lists dialog boxes in the Argus Application that must require passwords. In such cases, the system single sign on feature redirects the password to Argus for validation. When single sign-on is enabled, the system locks the user account if the user enters and incorrect password three consecutive time. The Administrator must unlock the account to enable the user to log in to the application.

Function Section Procedure
Case Locking Activities|Lock Locking a case
Case Unlocking Activities|Lock Unlocking a case
Case Closing Activities|Close Closing a case
Case Unclosing Activities|Close Unclosing a case.
Case Unblinding General|Blinding Status Breaking a blind
E2B Incoming Accept Reports|Incoming E2B Reports Accepting E2B Reports
E2B Incoming Reject Reports|Incoming E2B Reports Rejecting E2B Reports
E2B Incoming Follow-up Accept Reports|Incoming E2B Reports Accepting E2B Follow-up Reports
E2B Incoming Follow-up Reject Reports|Incoming E2B Reports Rejecting E2B Follow-up Reports
E2B Incoming Nullification Accept E2B Incoming Nullification Accept Accepting E2B Nullification Reports
E2B Incoming Nullification Reject E2B Incoming Nullification Reject Rejecting E2B Nullification Reports
LAM Incoming Local Affiliate Incoming Review Accepting an Affiliate Event
Workflow Routing Workflow Routing on Password on Route Workflow Routing on Password on Route

The following modules launched in the Argus Application, continue to use single sign on feature:

  • Argus Insight

  • Argus Perceptive

  • Argus Affiliate

  • Argus J

The following modules do not use the Single Sign on feature:

  • End of Study Unblinding

  • Argus Safety Services

  • Argus Interchange Services (ESM)

  • Argus Interchange Mapping (ESM Mapping Utility)

Error Messages

Once the user is configured, the system automatically logs the user into the Argus Application without requiring reauthentication on the Argus Login application. If there is an authentication error, the system displays the current login page so the user can log in manually.

Configuring SMTP

This screen enables you to configure SMTP.

Currently there are multiple issues such as, Outlook related problems with AG Service due to new security features introduced by Microsoft. Due to these security enhancements, a new method to submit e-mail from AG Service has been implemented using the SMTP Protocol.

Select System Configuration --> SMTP Configuration to view the SMTP configuration pop-up dialog. The pop-up dialog opens as shown.

Surrounding text describes smtpc.gif.

Field Descriptions

The following table lists and describes the fields associated with this section.

Field/Control Name Description
Server IP or Name Enables the user enter the SMTP server name / IP address.
Port Enables the user to enter the port number to use for SMTP server.
Authentication Enables the user to select the Authentication mode for SMTP configuration
SMTP User Name This is the username that the AG Service authenticates with for SMTP e-mail.
SMTP Password This is the password that the AG Service authenticates with for SMTP Emailing.

This field is required when Basic Authentication is selected in Authentication.

Enable SMTP When this checkbox is checked, SMTP is used by AG Service to send emails.

To modify SMTP

  1. Enter the SMTP Server IP or Name.

  2. Enter the Port number to use for SMTP server.

  3. Select the Authentication mode for the SMTP configuration, from the drop-down list.

  4. Enter the SMTP User Name.

  5. Enter the SMTP Password.

  6. Select Enable SMTP? to ensure that the AG Service implements SMTP to send e-mails.

  7. Click OK to save the changes made.

Configuring Workflow Items

The Workflow Items screen enables you to modify the options available for Workflow Items.

Select System Configuration --> System Management to view the Common Profile Configuration screen.

Tip:

The Common Profile folder appears in a tree-view on the left panel. The components are categorized as folders. Each folder contains all the field labels associated with that section.

To configure the fields associated with the User Interface section, click the Common Profile--> Workflow folder in the left panel. The configurable fields associated with Workflow appear in the right panel.

Surrounding text describes workflow.gif.

This section enables you to configure the total number of hours remaining for the present workflow state as well as the Total Number of the hours remaining for the case lock.

  • The first element displays the number of hours remaining for the case to be processed with the current workflow state.

  • The second element displays the number of hours remaining for the entire workflow for the case till Case Approval (Case Lock).

  • If the time remaining is less than the specified value in % for Yellow Indicator on the Case form for Dynamic Workflow, the elements are highlighted in yellow.

  • If the time remaining is more than the specified value in % for Yellow Indicator on the Case form for Dynamic Workflow, the elements are highlighted in green.

  • If the time remaining has exceeded the allocated time for the case process, the value is displayed in red, with the time displayed in negative.

  • The exceptions to this feature are those cases, which are archived and locked.

The Worklist>New and Worklist>Open also display a !" status beside Priority, denoting that the time remaining has exceeded the allocated time.

Surrounding text describes tnr.gif.

The total number of units is calculated by navigating across the possible routes the case can traverse. In case a case has to traverse through multiple possible routes, the preferred route is selected.

Field Descriptions

The following table lists the fields available under Workflow:

Field/Control Name Description
Case Routing The available options are:
  • Case form to close after use performs a manual routing

  • Case form to remain open

Display Locked/All cases on the worklist The available options are:
  • Display option on the Worklist screen to view Locked Cases requiring follow-up only. (Default)

  • Display all the cases at the time

Minimum length of the routing comment text length The available options are:
  • None

  • Text field

Display date for cases in the worklist The available options are:
  • Display Initial Receipt Date of the Case in the Worklist. (Default)

  • Display Follow-up Date of the Case in the Worklist. Follow-up date is the last entered follow-up date

Due Soon Duration (in Days) for Worklist Calculation Enter the number of days in which the worklist calculation is due.
Due Soon Red Indicator (in Days) for Worklist Display Enter the number of days in which the red indicator is to due to be displayed for the worklist.
% for Yellow Indicator on the Case form for Dynamic Workflow Enter the percentage for the yellow indicator on the case form for dynamic workflow. This field cannot have a value more than 99.
Enable Dynamic Workflow Timing Select this checkbox to view the dynamic workflow indicators on the case form.

To configure workflow items

  1. Select the option for Case Routing.

  2. Select the option for Display Locked/All cases on the worklist.

  3. Enter the Minimum length of the routing comment text length in the text box.

  4. Select the option for Display date for cases in the worklist.

  5. Enter the number of days in which the worklist calculation is due in Due Soon Duration (in Days) for Worklist Calculation.

  6. Enter the number of days in which the red indicator is to due to be displayed for the worklist in Due Soon Red Indicator (in Days) for Worklist Display.

  7. Enter the percentage for the yellow indicator on the case form for dynamic workflow in % for Yellow Indicator on the Case form for Dynamic Workflow.

  8. Select the Enable Dynamic Workflow Timing checkbox to view the dynamic workflow indicators on the case form.

  9. Click Save to save the changes made to this screen.

Configuring Workflow

When a case is received by the company and initial details have been entered and saved into Argus Safety, its status in the system becomes 'New' or 'Data Entry'. Various actions may be required before a case makes the transition from one workflow state to another.

Example: The case may require review, letters may need to be issued, the case may need to be reported elsewhere in the company, or regulatory reports need to be submitted to regulatory authorities. The case can be closed after all outstanding actions have been carried out and it flows through its life cycle.

For each stage in case processing, Argus Safety enables responsibility for cases to be assigned to specific user or group of users. Click the following link for information about how worklist permissions have changed.

Worklist Updates

The Worklist is driven by the group permissions defined for each user.

  • Granular permissions have replaced the current worklist options for the following worklist elements in group permissions:

    • Worklist - New

    • Worklist - Open

    • Worklist - Reports

    • Worklist - Action Items

    • Worklist - Coding Action Items

    • Worklist - Contacts

    • Worklist - Bulk Transmit

    • Worklist - Bulk Print

    • Worklist - Bulk E2B Transmit

    • Worklist - Local Labeling

    • Worklist - Coding Status

    • Worklist - Letters

    • Worklist - Intake (default is disabled)

  • If the worklist is disabled during the upgrade, then all the sub-elements are disabled; otherwise, all are enabled.

  • The default for New Group Creation is enabled.

  • The User Group Permissions Report has been updated to reflect granular permissions.

Configuring Case Workflow

Configuring case workflow involves configuration of:

  • Workflow States

  • Workflow Rules

Configuring Workflow States

This screen enables you to configure the workflow states. The following illustration shows the fields associated with this section.

Surrounding text describes wkstates.gif.

Field Descriptions

The following table lists and describes the fields available under Total Number of Rows:

Field/Control Name Description
State Name Displays the name of a workflow state.
State Description Displays a brief description about the workflow state.
Site Displays the site associated with a workflow state.

Tip:

Click Add New to add a new workflow state to the list of existing workflow states.

Use the following to modify workflow states

  1. Enter the name of the workflow state under State Name.

    Tip:

    This name is displayed as Case Status in the General Information section of the Case Form.
  2. Enter the description of the workflow state under Description.

  3. Select the site to be associated with the workflow state from the Site drop-down list.

  4. The drop-down list is populated with the configured user sites.

  5. Click Save to save the changes made.

Configuring Workflow Rules

This screen enables you to configure workflow rules. The following illustration shows the fields associated with this section.

Surrounding text describes wrkrules.gif.

Field Descriptions

The following table lists the Field Descriptions for this section.

Field/Control Name Description
From Defines the original state for the transition.
To Defines the destination state for the transition.
Group Specifies the group which will own the case once it moves from the From state to the To state (via this transition).

The drop-down list shall display all the configured user groups of Argus.

Normal Time (days) The workflow system monitors the time frames of each case in a state with respect to the Normal and Maximum parameters through AG Service.
  • The AG Service evaluates the status of each open case.

  • If a case has existed in its current state longer than the Normal time specified for the transition, the system raises the priority of the case by one level.

This escalation occurs only once for a case within a given state.

  • The case priority is not reset to its assigned priority upon transition.

  • If a case has existed in its current state longer than the Maximum time specified for the transition, the system raises its priority to level one (the highest priority).

  • In addition, an email notification is sent to the group's supervisor, indicating that the case has exceeded its maximum time.

  • The email message identifies the Case ID, Current State, Current Owner, and the time it has spent in its current state.

Max Time (days)
Units Enables the user to specify the number of units.
Product Group Enables the user to associate a specific Product group as additional criteria for the workflow transition.
Restrict to Workflow Group Enables the user belonging to the identified workflow rule group to have case access rights, based on the definitions of only the identified group.
Email When checked, the system sends an email notification to the user group address specified in group information whenever a case makes this particular transition.

By default, the checkbox is unchecked.

Require Password on Route
  • If the switch PASSWORD_ON_ROUTING" is disabled (0), the password option on the Workflow Dialog is not displayed and the Routing dialog does not ask the user for a password.
  • If the switch PASSWORD_ON_ROUTING" is enabled (1), the password option on the Workflow Dialog is displayed to users. If the Workflow Rule has the password option checked and the case being routed passes that workflow rule criteria, the password option is displayed on the routing dialog.

  • If the Workflow Rule that the case has passed does not have the Password option checked, no password option is displayed on the routing dial.

Lock Case on Route Enables the user to not require a password when routing the case.
Reason for not being able to route Enables the user to enter the description needed by the system to display while routing the case, when the case is ineligible to be routed to any of the configured To State".
Privileges to others Specifies the access rights for groups other than To Group' of the transition have to the case when it follows that transition. The choices are:
  • No Access

  • Read-Only

  • Read/Write (default)

Preferred State Enables the user to specify the preferred state for the rule.

To modify workflow rules

  1. Select the appropriate Filter Criteria.

    • Execute the following steps to apply a filtering criteria to search for specific workflow rules.

    • Select the check boxes to enable the drop-down lists containing a filtering criteria.

    • Select the appropriate filtering criteria from the drop-down lists.

    • Click Search to remove the selected criteria or click Apply Filter to apply the selected criteria. This displays the search results under Total Number of Rows.

  2. The entities in Total Number of Rows display the From and To states, the Advanced Condition, Group, Normal Time/Max Time and Number of User Defined Attributes in the Workflow.

  3. Select the rule displayed under Total Number of Rows that needs to be modified.

  4. The ModifyWorkflow Rules section is populated with information about the selected rule.

  5. Select the original state of the workflow rule from the From drop-down list.

  6. Select the destination state of the workflow rule from the To drop-down list.

  7. Select the group from the Groups drop-down list.

  8. Select the product from the Product Group drop-down list.

  9. Select the Email checkbox, if required.

  10. Select the Lock Case on Route checkbox, if required.

  11. Select the Require Password on Route checkbox, if required.

  12. Enter the number of days in the Normal Time (days) field.

  13. Enter the number of days in the Max. Time (days) field.

  14. Enter the number of units in the Units field.

  15. Select the preferred state for the rule from Preferred State.

  16. Select the relevant Advanced Condition, if any from the button.

    Tip:

    Click here for details on Advanced Conditions
  17. Enter the reason for not being able to route, if applicable, under Reason for not being able to route.

  18. Specify the access levels available to others from the Privilegesto others drop-down list. The options available under this list are No Access, Read-Only and Read/Write.

    Tip:

    Select the No Access option to disallow users outside the transition's group to open the case when it follows the transition.

    Select the Read-Only option to enable users outside the transition's group to view the case, but not to modify it.

    Select the Read/Write option to enable users outside the transition's group to modify the case when it follows the transition.

  19. Specify the checklist of items to appear under Checklist.

    Tip:

    The Checklist row cannot be left blank. Click Add and Delete to add and delete checklist items.
  20. Define custom attributes for a workflow rule under User Defined Attribute.

  21. Click Save to save the changes made.

Worklist Intake

This section provides information about the Worklist Intake feature.

Pending Dialog

The system enables the user to view a list of incoming attachments in Worklist View. In this view, the user can select an attachment for the case creation for Argus and Affiliate cases in the Pending dialog.

Surrounding text describes wrkintake.gif.

The following table lists and describes the fields available for the worklist

Field/Control Name Description Bookin Field Property
Review Case Enables you to marking incoming files as Review Case. The system display a checkmark next to the case to identify it as reviewed. N/A Drop-down menu item
Priority Enables you to view the priority of a case N/A Non-scrollable field label
Initial Date Enables you to view the Initial Receipt Date of the case. Initial Receipt Date Non-scrollable field label
Intake Date Enables the user to view the date the system imported the attachment in the Intake Worklist N/A Non-scrollable field label
Product Name Enables you to view the suspect product in questions. Product Name Scrollable field label
Generic Name Enables you to view the generic name of the suspect product in question. Generic Name Scrollable field label
Event PT Enables you to view the primary event and verbatim as reported N/A Scrollable field label
Event Verbatim The following format will be used:

Primary Event (Verbatim as Reported)

N/A Non-scrollable field label
Serious Enables you to view the Case Level Assessments Serious (Y/N) N/A Non-scrollable field label
F, LT, or H Fatal (F) or Life Threatening (LT) or Hospitalized (H)
  • If the case is Fatal, print F

  • If the case is Life Threatening, print LT

  • If the case is Hospitalized, print H

  • If any of the preceding are present together, Fatal takes precedence followed by LT, followed by H

  • If the case is neither, display No

Death for F

Hospitalized for H

Life Threatening for LT

Non-scrollable field label
Case Type Enables you to view report type information. Report Type Non-scrollable field label
Study ID Enables you to view the Study ID for the study cases

This field is empty for cases where the Study ID is not available.

Study ID Non-scrollable field label
Reporter Type Enables you to view the reporter type for the primary reporter in the case.

This field is empty if the reporter type is not available.

N/A Non-scrollable field label
Country Enables you to view the country of incidence Country of Incidence Scrollable field label
Central Site Enables you to view the current Argus or Affiliate site of the case.

You can view all the source documents from the site folder the user belongs to

Workflow enterprise users can view all cases across all site

N/A Scrollable field label
Attachment Name Enables you to view the attachment associated with the case. If there are multiple files, they are separated by a comma. N/A Non-scrollable field label link
Classification Enables you to view the attachment classifications associated with the attachment. Classification Scrollable field label
Description Enables you to view the attachment description associated with the case. Description Scrollable field label
View All Enables the administrator and workflow manager/enterprise to see all items in the system across all sites. N/A Radio button
Status Detail Enables you display the most current detailed information about a case. N/A Text
View Individual Enables you to view all items assigned to this user site.
  • If there are no sites defined then all users have access to the case attachment.

  • This button is disabled if the user is not a workflow manager or enterprise user.

N/A Radio button

Worklist Intake View

The following table describes the Worklist Intake View:

Argus Site Folder Worklist Intake View
US C:\USINTAKE All users belonging to the US site can see the case and workflow enterprise users.
DE C:\EUINTAKE All users belonging to the DE, FR, CH site can see the case and workflow enterprise users.
CH C:\EUINTAKE All users belonging to the DE, FR, CH site can see the case and workflow enterprise users.
FR C:\EUINTAKE All users belonging to the DE, FR, CH site can see the case and workflow enterprise users.
JP C:\JPINTAKE All users belonging to the JP site can see the case and workflow enterprise users.

Worklist
  • The system reads the XML that contains the preceding fields as tags and creates the Worklist based on the tags.

    <Cases>

    <Case>

    <PRIORITY>: Single number from 1 - 8. All others to be ignored

    <INITIAL_DATE>: Format of Date DD-MMM-YYYY

    <PRODUCT_NAME>: Text Field up to 70 Characters

    <GENERIC_NAME>: Text Field up to 70 Characters

    <EVENT_PT>: Text Field up to 250 Characters

    <EVENT_VERBATIM>: Text Field up to 250 Characters

    <SERIOUS>: Yes / No. All others shall be ignored

    <FLTH>: Format of F. All other after that shall be ignored

    <LT>: Format of LT All other after that shall be ignored

    <H>: Format of H. All other after that shall be ignored

    <CASE_TYPE>: Text field of report type

    <STUDY_ID>: Text field of Study ID

    <REPORTER_TYPE>: Text field of Reporter Type

    <COUNTRY_OF_INCIDENCE>: Text field of Country

    <ASSIGNED_TO>: Text field of User

    <GROUP>: Text field of Group

    <SITE>: Text field of Site

    <ATTACHMENTS>

    <ATTACHMENT>:

    <FILENAME>: Text field of Attachment File Name

    <DOCID>: Document ID from Document Storage System

    <CLASSIFICATION>: Text field of Attachment Classifications

    <DESCRIPTION>: Text field of Attachment Classifications Descriptions

  • The text on the worklist prints as specified in the XML and no lookup shall be performed.

  • If any of the Tag elements are empty they will be empty in the Intake Worklist.

  • If any fields are not available on the initial case entry, the system ignores them.

  • If there are multiple tags for the same element, the system retrieves the first tag element.

  • If the values do not match any elements in the Initial Case entry, the system ignores them.

  • The minimum fields required for the Attachment to be visible in the Intake Worklist are

    • Filename

    • DocID

    • DocID is only required if a central document system is enabled. If DocID is blank then the physical file with the same name as specified in the tag <Filename> is also required in the same folder.

  • If an error occurs while processing the Worklist, AG Service sends an e-mail to the General E-mail address.

  • The system enables you to select only one case at a time when creating cases in the Initial Case entry dialog.

    • When you select an attachment row and click Create case, the system locks the file to prevent others users from booking in the same case.

    • The system displays the following message:

      The case attachment is being currently used by XXXX user.

      where:

      XXXX is the full name of the user who has locked the attachment row

    • The system displays the standard Initial Case Entry where the system shall populate the fields within the XML Properties to the Initial Case entry dialog and display the PDF file for 40% of the screen (Similar to the New case from Image functionality)

    • If multiple attachments are available, the system opens them. The end user system must be setup to open multiple documents in the same window in Internet Explorer.

    • If the system is setup to use a central document storage system and the user clicks Create Case, the system retrieves the PDF from the central document system.

    • The system adds the attachment to the Initial Case entry dialog and also includes the Classifications and Descriptions for the attachment.

    • If the system is setup to use a central document storage system, Argus stores the document ID from the central document system. The file attachment will not be stored in Argus.

    • The system fills all available fields in the Initial Case Entry dialog with data from the XML Messages.

    • If you choose to open the cases after book-in, the system keeps the Attachment open in the split screen to enable the user to complete the case data entry.

    • If you book in the case from the Worklist Intake and chooses not to open the case from the Initial Case Entry dialog after book in is complete, the system returns to the Worklist Intake dialog.

  • When you perform a Duplicate Search and select a Case from the list, you can attach an incoming file to an existing case.

    • The system displays the Accept As Follow-up button and enables it when the user selects a case from the Duplicate search for the current Attachments to be added.

    • When you click Accept as Follow-up, the system opens the selected case and continues to display the Source attachments.

    • The system adds the attachments with the Classification and description (if provided) to the follow up case

    • The system opens multiple attachments if they are available. The end user system must be setup to open multiple documents in the same window.

  • Once you accept the initial or Follow up case and successfully create the case in Argus/Affiliate, the system generates an Acknowledgement in the OUT folder at the same level. For example, if the incoming folder for Site US is C:\USSITE\Incoming, the system generates ACKS in the C:\USSITE\OUT folder.

    • a. The Message format for the ACK is as follows:

      <CASES>

      <CASE>

      <CASE_NUMBER>: Argus Generated Case Number

      <PRODUCT_NAME>: Text Field up to 70 Characters for Primary Suspect Product of Case

      <DATETIME>: The Date and time in the DD-MMM-YYYY hh:mm:ss format when the file was accepted/rejected by the system

      <ATTACHMENTS>

      <ATTACHMENT>:

      <FILENAME>: Text field of Attachment File Name

      <DOCID>: Document ID from Document Storage System

  • If you click Copy to copy a case in Argus, the system generates an ACKS and puts it into the out folder for the site the original case belongs to. For example, Case A belongs to US Site and the user copies the case to Case B. The system creates an ACK in the US\Out Folder as configured in the US Site.

Rejected Cases

In Argus Safety, the Workflow Manager or Enterprise User can click Reject Case to reject cases from the Intake Worklist.

  • Affiliate Users can reject cases in the Intake Worklist.

    • When you try to reject a case, the system presents the Standard Justification dialog.

    • The Status row displays the following message:

      Case Rejected by XXXX on YYYY at MMM due to: ZZZZ

      where:

      XXX is the User Full Name,

      YYYY is the Date when the case was rejected in GMT

      MMM is the time in GMT

      ZZZ is the justification for rejecting the case as entered by the user.

    • Rejected Date: Date in GMT when the user rejected the case

    • Rejected By: User Full Name who rejected the case.

  • The system displays the Total number of Rows in the Worklist header section.

  • You can select the number of cases to display on the by selecting a value from page size drop-down list on the Worklist dialog.

  • The page drop-down list contains the following values:

    • 50

    • 100 (default)

    • 250

    • 500

    • 1000

    • 2000

  • The system displays the number of cases currently in view and updates the range automatically. For example. if you select 100 from the page size drop-down list, the system separates the displaying rows into groups of 100 cases.

  • The system enables you to go directly to a range of cases from the Displaying Rows drop-down list.

  • The system enables you to scroll through the Worklist page-by-page increments as defined by the Page Size drop-down list.

  • The system enables you to sort on ALL the columns in the Worklist view by clicking the header column. The system displays a triangle to show which column is sorted currently.

    • The initial sorted column is Initial Date.

    • The default sort order is ascending

    • Clicking the column header again, toggles between ascending and descending order.

  • The system maintains the worklist view with the sorting and filtering options defined by the user.

  • The Intake Worklist enables you to filter on each element.

  • The system enables you to filter on any element when you click the Filter button.

    • The system provides a Type Ahead feature to enables users to filter on any text/date element.

    • The system enables you to Close the filtering options by clicking the X icon on the filtering options.

    • If filtering criteria are specified, the Filter icon has the paper clip icon to indicate there are filtering elements.

    • The system permits a Like search (e.g. if you search for Cure, it returns all elements starting with Cure).

    • The system enables wild card searches. For example, if the user searches for %Cure, the system returns all elements containing Cure

    • Clicking the Search button enables you to filter for the reports in the list of reports.

    • These are filtering options are available from Worklist-specific views and when you drill down for cases or reports.

  • The system saves all user preferences for future use.

  • Clicking the Search button enables you to filter the elements on the dialog.

User Site Updates and Access Management

You can configure the Path for the File Intakes per Site (Argus and LAM) in the Site configuration

  • When you click the Browse button, the system enables you to browse to the Folder for the Site where the XMLS and the PDFS shall be stored

  • The Path length shall be up to 255 characters

    Surrounding text describes usersitebk.gif.

  • The current Worklist options are replaced with granular permissions for Worklist elements in the Group Permissions as per the following:

  • Worklist Intake (default is disabled)

  • The Audit Log tracks the updates made to Site Configuration

  • The User Site print out displays the File Intake Path.

Configuring System Numbering

This screen enables you to specify the case numbering preferences. Select System Configuration --> System Numbering to view the LAM System Numbering screen.

The screen appears as shown.

Surrounding text describes sysnum.gif.

Field Descriptions

The following table lists and describes the fields for this section.

Field/Control Name Description
Manually Number Cases Enables the user to manually number the cases on booking or while copying the case, using the save as' option on the case form.
Automatically Number Cases On selection, the system automatically numbers the cases as defined by the user in the numbering format.
Start at Enables the user to initialize the counter of the sequence number.
Separate sequence for each site Enables the user to separate the sequence numbering for cases on site by site basis. If there are cases being entered from two different sites then each site will have different sequencing of case numbers.
Separate sequence for each report type Enables the user to separate the sequence numbering for cases by the report type of the case.
Separate sequence for each year Enables the user to reset the sequence numbering for cases after each year based on the initial receipt date of the case.
Separate sequence for each month Enables the user to reset the sequence numbering for cases after each month based on the initial receipt date of the case.
Separate sequence for each product abbreviation Enables the user to reset the sequence numbering for cases for each different product abbreviation.
Numbering Format Enables the user to select the numbering format by selecting the different placeholders.

Define the numbering format by typing in custom keywords to print on every case number and selecting different placeholders.

[YY][MM]-[###] is the default format.

Placeholder Placeholders are used to pickup values from the database to be used in the Case numbering format.

The possible values populated in this list are:

# - Number: defines the digits to be used as the sequence number in the format. The field is used to display the sequence number on the case numbers.

CC- Country Code: When selected, this uses the A2 code for the country of incidence for the case number.

DD - Day: When selected, this uses the date of the Initial receipt date' field of the case.

MM - month: When selected, this uses the month of the Initial receipt date' field of the case.

P - When selected, this uses either of the two values:

If report type is Spontaneous' or other' during booking: the system uses the value of the Product Abbreviation' field specified in the Product configuration for the selected Primary suspect product.

If report type is of the type report from study' during booking: the system uses the Product Abbreviation' field specified in the study configuration.

SSS - User Site: When selected this uses the Site abbreviation of the site belonging to the user who booked in the case.

TTT - Report Type: When selected this uses the report type abbreviation of the report type selected during bookin of the case.

YY- Year: When selected, this uses the year of the Initial receipt date' field of the case.


To configure LAM system numbering

  1. Select the Numbering feature as required. This can be manual numbering or automatic numbering of cases.

  2. Select the Sequencing Options as required.

    Tip:

    For the complete explanation of the sequencing options refer to the Field Descriptions
  3. Select the Numbering Format.

    Tip:

    To customize the Numbering Format, use the placeholder values.

    Example: To select Country Code, Month and Year (as values to be incorporated from the database) as the Case numbering format, execute the following steps.

    • Click on Country Code. This appears in the Numbering Format field.

    • Click on Month. This appears in the Numbering Format field next to the Country Code.

    • Click on Year. This appears in the Numbering Format field next to the Country Code and Month.

    The final data listed in the Numbering Format field is the Case Numbering Format.

  4. Click Save to save the changes made.

Configuring Field Labels

This section enables you to change field label names and hide or display fields in the Case Form.

Select System Configuration --> Field Labels to view the Case Form Field Configuration screen shown in the following illustration.

Surrounding text describes cffc.gif.

Tip:

The Case Form tabs appear in the left panel and are categorized as folders. Each folder contains all the field labels associated with that section.

For example, the General Tab in the Case Form contains sections such as Study, Follow-Up, Case Literature etc.

  • To view the list of field names associated with the Study section, click Study in the left panel.

  • The field names associated with Study appear in the right panel.

Field Descriptions

The following table describes the fields associated with this section.

Field/Control Name Description
Field Name Enables the user to view the field name. This is a read only field.
Field Form Label Enables the user to enter the field label names for those fields that can be edited.
Help Text Enables you to enter help text for fields that can be edited.
Selectable When checked, enables you to???
Read Only Enables you to make inrug, device, or vaccine field read- only.
Drug Enables the user to make a field Read only in the Product tab, when the Argus user chooses Drug" option on the Product screen.
Device Enables the user to make a field Read only in the Product tab, when the Argus user chooses "Device" option on the Product screen.
Vaccine Enables the user to make a field Read only in the Product tab, when the Argus user chooses th "Vaccine" option on the Product screen.
Hidden Enables the user to hide or display a field by clicking the radio button.

Select Yes to hide the field on case form; select No to display the field on case form.

Note: Some fields cannot be hidden. Hidden fields do not appear in the case form printout.

E2B Field When checked, shows which fields are required for E2B.

Use the following to modify case form field names.

  1. Select the folder (or section) in the left pane, for which the field names are to be modified.

  2. The places the list of field labels associated in the right panel.

  3. Click on the Field Name to be modified.

  4. The system highlights the selected row is highlighted and puts the details about this field in the Modify section at the bottom of the screen.

  5. Enter the new field name in Field Form Label.

    Tip:

    This label appears in the Case Form section.
  6. Select the Hidden preference. Select Yes if you want to hide the field on the Case Form.

  7. Click this checkbox to indicate which fields are required for E2B.

  8. Select any or all of the following options Drug, Device or Vaccine as Read Only based on your requirement.

  9. Click Save to save the changes made.

Note:

Label Changes will not be reflected in Argus Case Form unless IIS is reset.

Configuring User Defined Fields

The Argus Safety administrator can customize a user-defined field as a drop-down list. These drop-down lists may contain customized lookup data which can be independent of Argus data.

To create a user-defined field

  1. Identify the User Defined field in the CMN_FIELDS table.

  2. Create a custom table containing lookup information.

  3. Create a custom index and specify the required values for the table.

  4. Update the record in the CMN_FIELDS table for the User Defined Field.

  5. Create a Role and Synonym for the table.

  6. Restart IIS.

  7. Verify the update made in the application.

Consider the following example that show a sample set of scripts required to configure User Defined Fields as a drop-down list. Assume the requirement is for a User Defined Field (UDF) with the following features:

Requirement: A User Defined field "SOURCE_OF_INFORMATION" to be created, with its drop-down values as Fax, E2B, Letter, Email and Telephone under Case Form -> General Tab -> General Information.

Attribute Value
Field Name SOURCE_OF_INFORMATION
Drop-down Values Fax, E2B, Letter, Email and Telephone
Field Location Case Form => General tab => General Information

To create a user-defined field

  1. Login to Argus --> Argus Console --> System Configuration --> Field Labels.

  2. Enter the Field Form Label as Source of Information.

  3. Select No against Hidden and click Save.

  4. Query the following required field for an update, based on the field_label

    SELECT

    field_ID, field_label, table_name, column_name, tree_view, data_type, data_length

    FROM

    cmn_fields

    WHERE

    field_label LIKE '%SOURCE_OF_INFORMATION%';

  5. Create a Custom Table

    create table pf_SOURCE_OF_INFORMATION(

    pf_SOURCE_OF_INFORMATION_code number,

    pf_SOURCE_OF_INFORMATION_desc varchar2(100))

    /

  6. Create a Custom Index

    create index idx_pf_SOURCE_OF_INFORMATION

    on pf_SOURCE_OF_INFORMATION (pf_SOURCE_OF_INFORMATION_code)

    /

  7. Insert values

    insert into pf_SOURCE_OF_INFORMATION values (1, MI Fax');

    insert into pf_SOURCE_OF_INFORMATION values (2, MI E2B');

    insert into pf_SOURCE_OF_INFORMATION values (3, MI Letter');

    insert into pf_SOURCE_OF_INFORMATION values (4, MI Email');

    insert into pf_SOURCE_OF_INFORMATION values (5, MI Telephone');

  8. Update CMN_FIELDS table

    update cmn_fields

    set join_type = 1,

    GUI_field_type = 6,

    field_length = 100,

    JOIN_FLD_ID = 50001,

    select_table = 'pf_SOURCE_OF_INFORMATION',

    join_field = 'PF_SOURCE_OF_INFORMATION_CODE',

    select_column = 'PF_SOURCE_OF_INFORMATION_DESC'

    where field_id = 2150032

    /

    commit;

    /

  9. Grant select to ARGUS_ROLE

    grant select on pf_SOURCE_OF_INFORMATION to argus_role;

  10. Create Public Synonym

    create public synonym pf_SOURCE_OF_INFORMATION for argus_app.pf_SOURCE_OF_INFORMATION;

  11. Restart the Web Server

  12. Go to the command prompt and enter the iisreset command for changes to take effect.

  13. Verify the outcome from the front end

  14. Login to Argus Safety and open a Case Form.

Go to General tab | General Information and check that the configured user-defined fields display the updated drop-down text.