3 E2B Check

In order to successfully transmit any E2B Report, it must validated for its mandatory components before transmitting the report.

Why perform an E2B Check

You can run an E2b check by clicking the E2B icon from the Quick Launch menu shown below.

Surrounding text describes quicklaunch.gif.

Note: The E2B check icon is visible on the Quick Launch Toolbar ONLY if a case is open and active on the user session.

Running an E2b check validates if the E2b report has all these mandatory elements present that is required for its successful processing.This check performs the function that prints the “E2B Report – DTD Length Check Warnings” and “E2B report – DTD Validation”.

The following illustration shows a sample E2b check report that is generated in PDF format:

Surrounding text describes pdf2.gif.

As can be seen in the PDF, the sample report displays the case form fields where the validation error has occurred.

Apart from the case form location where the error occurred, the report lists the type of error, data elements, DTD elements, the actual message/cause of the error, and the profiles which were tested for each validation type.

The validation checks are profile-dependent but every E2B check report tests for Mandatory Elements check and Mandatory Optional Elements check.

E2B check also verifies if AN fields (Allow Japanese Characters=No) has an undefined character in the Profile Switch.E2B check displays the following error message when invalid character(s) (characters not configured in the Profile switch) are found in the E2B item:"Value of element [element tag] has invalid English character(s)."Argus J E2B Check and E2B generation execute Japanese Language Check on E2B items marked as "Allow Japanese characters".

E2B check verifies the Japanese language. The default values for "Allow Japanese characters" flag are given in PMDA_mapping.The checking of the Japanese Language is performed in i. E2B checkii. E2B Generation This is configurable from the Argus J Profile switch "Perform Japanese character validation at E2B Check and E2B Report Generation." It is checked by default. The Japanese language check is performed only when this is checked. The user can add invalid Japanese character to be checked in Japanese Language check in the profile switch: "Additional invalid characters to be checked in Japanese character validation". If you receive an error message stating that the "Value of element [element tag] has invalid Japanese character(s)", it means that some invalid Japanese characters have been found.