Oracle Fusion Middleware Data Visualization Tools Tag Reference for Oracle ADF Faces 11g Release 1 (11.1.1.5.0) E12418-07 |
Use the x1Axis tag to control the characteristics and scaling of the x1-axis.
This component must be a child of one of the following components:
Note that use of x1Axis's <dvt:numberFormat> tag has been deprecated. Users are recommended to use the x1TickLabel's <af:convertNumber> tag instead:
The following example shows the XML for a x1Axis tag that starts at the value 0.0.
<dvt:graph> <dvt:x1Axis lineWidth="1" lineColor="#000000" scaledLogarithmic="false" logarithmicBase="10.0" axisMinAutoScaled="true" axisMinValue="0.0" axisMaxAutoScaled="true" axisMaxValue="100.0" majorIncrement="15.0" minorIncrement="5.0" scrolling="on"/> </dvt:graph>
Name | Type | Supports EL? | Description |
---|---|---|---|
id | java.lang.String | no | Specifies the identifier for the component |
lineColor | java.lang.String | yes | Specifies the color of the axis line. Enter values in RGB hexadecimal. The example color="#000000" specifies black. This color property takes 6 or 8 digit hex as input. When 8 digit hex is used, the first 2 digits represent transparency, otherwise the color is opaque. |
lineWidth | int | yes | Specifies the width of the axis line in pixels. The width is 1 pixel by default. |
logarithmicBase | double | yes | Specifies the base for the log scale on this axis, applies only when scaledLogarithmic is true. |
majorIncrement | double | yes | The distance between two major tick marks. If less than or equal to 0 major increments will not be shown. The major tick are the ones that will display a labeled value underneath the tick mark. Setting this attribute will apply majorTickStepAutomatic to false. Note: The number of major tick marks is limited to 100 in the visible plot area. |
minorIncrement | double | yes | The distance between two minor tick marks. If less than or equal to 0 minor increments will not be shown. The minor tick are the ones that will not show a label underneath the tick mark. By default, x1MinorTick tickStyle is none. User needs to modify this attribute to see the minor tick marks. Note: The number of minor tick marks is limited to 500 in the visible plot area. |
majorTickStep | double | yes | Deprecated. Replaced by majorIncrememt. The increment between tick marks. This setting applies only if the majorTickStepAutomatic attribute is set to "false". |
axisMaxValue | double | yes | Specifies the maximum value to appear on the axis. This setting applies only when axisMaxAutoScaled is "false". |
axisMinValue | double | yes | Specifies the minimum value to appear on the axis. This setting applies only when axisMinAutoScaled is "false". |
axisMaxAutoScaled | boolean | yes | Specifies whether the maximum value of the axis is set automatically by the graph. Valid values are "true" (Default) and "false". |
axisMinAutoScaled | boolean | yes | Indicates whether the minimum value of the axis is set automatically by the graph. Valid values are "true" (Default) and "false". |
majorTickStepAutomatic | boolean | yes | Deprecated. Indicates whether major tick mark values on this axis are set automatically. Valid values are "true" (Default) and "false" |
scaledLogarithmic | boolean | yes | Specifies whether the axis uses a log scale. Valid values are "true" and "false" (Default). |
rendered | boolean | yes | Indicates whether the axis line is rendered. Valid values are "true" (Default) and "false". |
scrolling | boolean | yes | Specifies the axis scrolling behavior. Supported for Scatter and Bubble graphs only. Valid values are:
|