The DiagnosticsHarvester1.0 catalog contains messages in the range
BEA-320300 - BEA-320399. Messages in this catalog are part of the
weblogic.diagnostics.i18n
Internationalization package and the weblogic.diagnostics.l10n
Localization package.
BEA-320300
|
Error: The WLS ServerRuntime MBeanServer was not available for harvesting; custom MBean harvesting will not be available.
Description
| The WLS ServerRuntime MBeanServer could not be loaded and registered with the Diagnostics subsystem for harvesting. The ServerRuntime MBeanServer is required for harvesting of custom MBean types for user applications. |
Cause
| This could be the result of a serious error in the OA&M infrastructure; check for other error messages in the log in that area. |
Action
| Contact Oracle Customer Support. |
|
BEA-320301
|
Error: The WLDF Harvester could not activate the Watch and Notifications framework due to an exception: t
Description
| The deferred activation of the Watch and Notifications framework failed due to an unexpected exception. |
Cause
| During server startup the Watch and Notifications activation is deferred until the WLDF Harvester is fully activated. The deferred activation encountered an unexpected exception, potentially impairing the W&N functionality. |
Action
| Contact Oracle Customer Support. |
|
BEA-320302(retired)
|
Error: The value namespace is not a valid WLDF Harvester namespace; it can be only one of "ServerRuntime" or "DomainRuntime".
Description
| The value namespace is not a valid WLDF Harvester namespace; it can be only one of "ServerRuntime" or "DomainRuntime". |
Cause
| The specified namespace namespace was not one of the supported values. |
Action
| Correct the namespace declaration of the harvested type. |
|
BEA-320303
|
Warning: The namespace namespace for the harvested type specification type can not be serviced by a managed server instance; it is only valid only when targed to an administration server.
Description
| Managed servers can not service harvested types for the namespace namespace; only administration servers can service such types. The requested harvested type will not be collected for this server. |
Cause
| A harvested type specifying the DomainRuntime namespace was targeted to a managed server. A managed server can only service the ServerRuntime namespace. |
Action
| Correct the namespace declaration of the harvested type, or retarget the WLDF configuration to an administration server in order to service this type. |
|
BEA-320304
|
Warning: The following errors were reported during the validation of the metrics for watched values wvName: errors
Description
| The harvester could not service some of the metrics specified in the configuration. |
Cause
| Some of the configured harvested types may have errors resulting in the harvester being unable to process them for collection. |
Action
| Correct any issues with the harvested type configuration. |
|
BEA-320305
|
Error: The instance name instanceName not a valid ObjectName or instance name pattern.
Description
| The instance name instanceName not a valid ObjectName or instance name pattern. |
Cause
| The instance name must be a valid JMX ObjectName, or a pattern conforming to the syntax supported by the Diagnostics Framework. |
Action
| Correct the instance name in the harvested type. |
|