The BPEL Interpreter catalog contains messages in the range
BEA2031750 - BEA2031799. Messages in this catalog are part of the
com.bea.bpel.interpreter.internal.instruction.messages
Internationalization package and the
com.bea.bpel.interpreter.internal.instruction.messages
Localization package.
BEA-2031750
|
Error: The evaluates to null.
Description
| The ''to'' node of a copy evaluates to null. It should evaluate to a a non-null value. |
Action
| Ensure that the ''to'' node evaluates to a non-null value. |
|
BEA-2031751
|
Error: The evaluates to null.
Description
| The ''from'' node of a copy evaluates to null. It should evaluate to a a non-null value. |
Action
| Ensure that the ''from'' node evaluates to a non-null value. |
|
BEA-2031752
|
Info: Exiting process instance due to .
Description
| The process instance was exited due to a ''exit'' in the process definition. |
|
BEA-2031753
|
Error: The value returned is a 'value' when a boolean was required.
Description
| Conditions should evaluate to a boolean value but this condition did not. |
Action
| Ensure that the condition always evaluates to a boolean value. |
|
BEA-2031754
|
Error: Received an unexpected response for invoke (operation is 'operation').
Description
| The Invoke received a response from the invocation but it was not expected because the exchange pattern was not IN_OUT. |
Action
| Ensure that the partner link being invoked has the expected exchange pattern. |
|
BEA-2031755
|
Error: Expected a fault or output response for invoke but got neither.
Description
| The Invoke expected a response from the invocation but none was received. |
Action
| Ensure that the partner link being invoked has the expected exchange pattern of IN_OUT. |
|
BEA-2031756
|
Info: Fault returned from Invoke.
Description
| The Invoke received a fault response from the invocation. |
|
BEA-2031757
|
Error: The alarm definition 'alarm' defines no deadline, duration or repeat interval.
Description
| An alarm must contain a deadline, duration or a repeat interval. This should be caught by validation during deployment. |
Action
| Modify the alarm to define a deadline, duration or a repeat interval. |
|
BEA-2031758
|
Error: The value returned 'value' must be positive.
Description
| A repeat interval must be a positive integer. |
Action
| Ensure that the repeat every interval expression evaluates to a positive integer. |
|
BEA-2031759
|
Error: The expression 'expression' is an invalid deadline.
Description
| The deadline expression must evaluate to an XML Schema date or datetime. |
Action
| Ensure that the deadline expression evaluates to an XML Schema date or datetime. |
|
BEA-2031760
|
Error: The expression 'expression' is an invalid duration. It should be in the form PnYnMnDTnHnMnS.
Description
| The duration expression must evaluate to an XML Schema duration. eg. For 1 day and 10 seconds use P1DT10S See http://www.w3.org/TR/xmlschema-2/#duration for details. |
Action
| Ensure that the duration expression evaluates to an XML Schema duration. |
|
BEA-2031761
|
Info: Exiting process instance due to unhandled standard fault ('fault').
Description
| A standard BPEL fault (other than joinFailure) was thrown but 'exitOnStandardFault' was set to yes. This exits the process instance without any fault handling. |
|
BEA-2031762
|
Error: WSDL operation for operation 'operation' not found.
Description
| The WSDL operation was not found in the process metadata. This should be caught by validation during deployment. |
Action
| Contact Technical Support. |
|
BEA-2031763
|
Error: The completion condition must be a number, but the expression evaluated to 'value'.
Description
| The completion condition must evaluate to an XML Schema unsigned integer. |
Action
| Ensure that the completion condition evaluates to an XML Schema unsigned integer. |
|
BEA-2031764
|
Error: The completion condition value of 'value' is invalid.
Description
| The completion condition must evaluate to a positive integer. |
Action
| Ensure that the completion condition evaluates to a positive integer. |
|
BEA-2031765
|
Error: Timer expression 'expression' is invalid: errors
Description
| The timer expression is not valid according to the XML Schema for deadlines or durations (depending on which expression it is). The exception message should indicate where the error is. |
Action
| Correct the expression according to the exception message. |
|
BEA-2031766
|
Error: The date value 'value' is invalid.
Description
| The date value is not a valid XML Schema date or datetime. |
Action
| Ensure that the date is a valid XML Schema date or datetime. |
|
BEA-2031767
|
Info: The fault 'fault' has been thrown by the process.
Description
| A fault has been explicitly thrown in the process due to a 'throw'. |
|
BEA-2031768
|
Error: The start counter value must be a number, but the expresion evaluated to 'value'.
Description
| The start counter value must evaluate to an XML Schema unsigned integer. |
Action
| Ensure that the start counter value evaluates to an XML Schema unsigned integer. |
|
BEA-2031769
|
Error: The start counter value of 'value' is invalid.
Description
| The start counter value must evaluate to a positive integer. |
Action
| Ensure that the start counter value evaluates to a positive integer. |
|
BEA-2031770
|
Error: A final counter value must be a number, but the counter evaluated to 'value'.
Description
| The final counter value must evaluate to an XML Schema unsigned integer. |
Action
| Ensure that the final counter value evaluates to an XML Schema unsigned integer. |
|
BEA-2031771
|
Error: The final counter value 'value' is invalid.
Description
| The final counter value must evaluate to a positive integer. |
Action
| Ensure that the final counter value evaluates to a positive integer. |
|