7 Hardware Views

This chapter provides a description of each hardware view and its columns. It contains the following sections:

For examples of how to use views, see Chapter 20, "Examples".

7.1 Hardware Views

This chapter provides a description of each hardware view and its columns

7.1.1 MGMT$HW_CPU_DETAILS

The MGMT$HW_CPU_DETAILS view returns a summary of hardware CPU details.

Table 7-1 MGMT$HW_CPU_DETAILS

Column Description

TARGET_TYPE

Type of target for this metric

TARGET_NAME

The name of the target

VENDOR_NAME

The name of the hardware vendor

FREQUENCY_IN_MHZ

The frequency measured in MHz

ECACHE_IN_MB

The size of the ecache measured in MB

IMPL

The details of the implementation

REVISION

The revision details

MASK

The mask details

INSTANCE_COUNT

This is a count of the CPU devices

NUM_CORES

The number of cores per physical CPU

IS_HYPERTHREAD_ENABLED

Defines whether hyperthreading is enabled for this physical CPU (set to 0 or 1)

SIBLINGS

Total number of logical processors for this physical CPU

SNAPSHOT_GUID

The globally unique identifier of the snapshot

TARGET_GUID

The globally unique identifier of the target

LAST_COLLECTION_TIMESTAMP

The date-time of the last collection


7.1.2 MGMT$HW_NIC

The MGMT$HW_NIC view returns a summary of hardware network interface card (NIC) information.

Table 7-2 MGMT$HW_NIC

Column Description

TARGET_TYPE

Type of target for this metric

TARGET_NAME

The name of the target

HOST_NAME

The name of the host

NAME

The NIC name

INET_ADDRESS

The NIC address

MAX_TRANSFER_UNIT

The NIC maximum transfer unit

BROADCAST_ADDRESS

The NIC broadcast address

FLAGS

The NIC flags

MASK

The NIC masks

MAC_ADDRESS

The NIC MAC address

MAC_ADDRESS_STD

The STD NIC MAC address

DHCP_ENABLED

Defines whether DHCP is enabled (set to Y or N)

HOST_ALIASES

The NIC host aliases

INET6_ADDRESSES

The Ipv6 addresses of the host

SNAPSHOT_GUID

The globally unique identifier of the snapshot

TARGET_GUID

The globally unique identifier of the target

LAST_COLLECTION_TIMESTAMP

The date-time of the last collection

IS_PHYSICAL

Defines whether the NIC is physical or not (set to 0 or 1)


7.1.3 MGMT$HW_NIC_BONDS

The MGMT$HW_NIC_BONDS view returns a summary of hardware network interface card (NIC) bonds information.

Table 7-3 MGMT$HW_NIC_BONDS

Column Description

TARGET_TYPE

Type of target for this metric

TARGET_NAME

The name of the target

BOND_NAME

The name of the bond

PRIMARY_SLAVE

The primary slave of the bond

SECONDARY_SLAVES

The secondary slaves of the bond

BOND_MODE

The mode of the bond, for example, Balanced

OPTIONS

The options used when the bond is created

SNAPSHOT_GUID

The globally unique identifier of the snapshot

TARGET_GUID

The globally unique identifier of the target

LAST_COLLECTION_TIMESTAMP

The date-time of the last collection


7.1.4 MGMT$HW_IO_DEVICES

The MGMT$HW_IO_DEVICES view returns a summary of IO device details.

Table 7-4 MGMT$HW_IO_DEVICES

Column Description

TARGET_TYPE

Type of target for this metric

TARGET_NAME

The name of the target

VENDOR_NAME

The vendor name

NAME

The name of the IO device

FREQ_IN_MHZ

The frequency in MHz

BUS

The bus type

REVISION

The revision of the IO device

INSTANCE_COUNT

This is a count of the IO devices that have the same vendor name, name, and so on

SNAPSHOT_GUID

The globally unique identifier of the snapshot

TARGET_GUID

The globally unique identifier of the target

LAST_COLLECTION_TIMESTAMP

The date-time of the last collection


7.1.5 MGMT$EM_ECM_HOST_VIRTUAL

The MGMT$EM_ECM_HOST_VIRTUAL view returns virtualization properties of the Host targets.

Note:

The MGMT$EM_ECM_HOST_VIRTUAL view is available for release 12.1.0.4 and later only.

Table 7-5 MGMT$EM_ECM_HOST_VIRTUAL

Column Description

HOST_NAME

Name of the Host target name

TARGET_NAME

Name of the target

TARGET_GUID

Globally unique identifier of the target

ECM_SNAPSHOT_ID

ECM Snapshot ID of the current snapshot for Host target

NAME

Virtualization Property Name

VALUE

Virtualization Property Value


7.1.6 MGMT$HW_HOSTS_FILE

The MGMT$HW_HOSTS_FILE view returns details of the hosts file (/etc/host) in parsed format.

Note:

The MGMT$HW_HOSTS_FILE view is available for release 12.1.0.4 and later only.

Table 7-6 MGMT$HW_HOSTS_FILE

Column Description

TARGET_NAME

Name of the target

IP_ADDRESS

IP address

VALUE

Fully qualified domain name, alias, and so on.

SNAPSHOT_GUID

ECM Snapshot ID of the current snapshot for Host target

TARGET_GUID

Globally unique identifier of the target

TARGET_TYPE

Type of target

LAST_COLLECTION_TIMESTAMP

Date-time of the last collection


7.2 Service Tag Views

This section provides a description of each service tag view and its columns. It contains the following sections:

7.2.1 MGMT$SERVICETAG_INSTANCES

The MGMT$SERVICETAG_INSTANCES view provides information about the product ID and instance of the product installed on the server, such as Oracle Solaris Cluster.

Table 7-7 MGMT$SERVICETAG_INSTANCES

Column Description

PRODUCT_URN

Denotes the product ID for the product installed on the server

INSTANCE_URN

Uniquely identifies the instance of the product installed on that server


7.2.2 MGMT$SERVICETAG_REGISTRY

The MGMT$SERVICETAG_REGISTRY view uniquely identifies the instance of a Service Tag registry on a server and the version of Service Tag software that created it.

Table 7-8 MGMT$SERVICETAG_REGISTRY

Column Description

AGENT_ID

Uniquely identifies the instance of a Service Tag registry on the server

AGENT_VERSION

Uniquely identifies the version of the Service Tag software

REGISTRY_VERSION

Identifies the version of the registry. This is the registry that Oracle Configuration Manager (OCM) harvests to collect the data for this metric.