8.6. How to Change the Smart Card Bus Protocol

By default, scbus v1 is enabled on the Sun Ray server. Choose the scbus version based on your environment:

Admin GUI Steps
  1. Click the Advanced tab.

  2. Click the Security subtab.

  3. In the Devices section, choose the scbus version in the Internal Smart Card Reader field under the Devices section.

  4. Click Save.

  5. Restart Sun Ray services using the Cold Restart button located on the Servers page.

Command Line Steps
  1. Become superuser on the Sun Ray server.

  2. Change the smart card bus protocol.

    # /opt/SUNWut/sbin/utdevadm -p scbus -v version-number

    where version-number can be v1 or v2. You can use the -p scbus with no other options to view the current scbus version set on the Sun Ray server.

  3. Restart the Sun Ray services for the new protocol to take effect.

    # /opt/SUNWut/sbin/utstart -c