By default, scbus v1 is enabled on the Sun Ray server. Choose the scbus version based on your environment:
scbus v1 - Specify if managing Sun Ray Clients running Sun Ray Software 5.2 firmware or earlier.
scbus v2 - Specify if managing Sun Ray Clients running Sun Ray Operating Software 11.0 or later or if managing Oracle Virtual Desktop Clients version 3.1 or later.
Click the Advanced
tab.
Click the Security
subtab.
In the Devices
section, choose the scbus
version in the Internal Smart Card Reader
field under the Devices section.
Click Save
.
Restart Sun Ray services using the Cold
Restart
button located on the Servers page.
Become superuser on the Sun Ray server.
Change the smart card bus protocol.
# /opt/SUNWut/sbin/utdevadm -p scbus -v version-number
where version-number
can be
v1
or v2
. You can use
the -p scbus
with no other options to view
the current scbus version set on the Sun Ray server.
Restart the Sun Ray services for the new protocol to take effect.
# /opt/SUNWut/sbin/utstart -c