WSNAT Messages 1100-1199
1100
ERROR: -n option is required
Description
The workstation listener (WSL
) process was invoked without the -n
option. This parameter contains the well-known network address used by the workstation listener, and is required. The WSL
process is exiting due to the absence of a required option.
Action
Examine the configuration file and determine the change that needs to be made to the CLOPT
argument for the WSL
process. The -n
option must occur, must have an appropriate option argument, and must be located after the double dash, --
, that separates TUXEDO System/T options from WSL
specific options. The options for a server may be updated while the system is running through use of the tmconfig
(1) command, or may be updated while the system is shut down by reloading the configuration file using tmloadcf
(1).
See Also
tmconfig
(1), tmloadcf
(1), WSL
(5)
1101
ERROR: Bad hex number provided for listening address: bad_hex_value
Description
The workstation listener (WSL
) process was invoked with a -n
option that specified a hexadecimal value as an option-argument. However, the value specified was not a valid hexadecimal constant.
Action
Change the network address specified for the WSL
so that it contains an even number of hexadecimal digits, and make certain that each digit is '0' through '9', 'A' through 'F', or 'a' through 'f'. Also, remember that the WSNADDR
environment variable in client processes associated with this WSL
must be set to this same address. The option and its associated network address are part of the CLOPT
parameter specified for the WSL
process in the configuration file. The options for a server may be updated while the system is running through use of the tmconfig
(1) command, or may be updated while the system is shut down by reloading the configuration file through use of tmloadcf
(1).
See Also
tmconfig
(1), tmloadcf
(1), ubbconfig
(5), WSL
(5)
1103
ERROR: Bad -m option
Description
The workstation listener (WSL
) process was invoked with a -m
option that specified an option-argument outside of the allowed range. The -m
option specifies the minimum number of handlers that should be available in conjunction with this WSL
at any given time. The legal range is between 0 and 255. The WSL
process is exiting due to an error in its arguments.
Action
Change the value for the WSL
-m option so that it is within the legal range. The options for a server may be updated while the system is running through use of the tmconfig
(1) command, or may be updated while the system is shut down by reloading the configuration file through use of tmloadcf
(1).
See Also
tmconfig
(1), tmloadcf
(1), ubbconfig
(5), WSL
(5)
1104
ERROR: Bad -x option
Description
The workstation listener (WSL
) process was invoked with a -x
option that specified an option-argument outside of the allowed range. The -x
option specifies the degree of multiplexing desired within each workstation handler. The legal range is between 1 and 32767. The WSL
process is exiting due to an error in its arguments.
Action
Change the value for the WSL
-x
option so that it is within the legal range. The options for a server may be updated while the system is running through use of the tmconfig
(1) command, or may be updated while the system is shut down by reloading the configuration file through use of tmloadcf
(1).
See Also
tmconfig
(1), tmloadcf
(1), ubbconfig
(5), WSL
(5)
1105
ERROR: Bad -M option
Description
The workstation listener (WSL
) process was invoked with a -M
option that specified an option-argument outside of the allowed range. The -M
option specifies the maximum number of handlers that should be available in conjunction with this WSL
at any given time. The legal range is between 1 and 32767. The WSL
process is exiting due to an error in its arguments.
Action
Change the value for the WSL
-M
option so that it is within the legal range. The options for a server may be updated while the system is running through use of the tmconfig
(1) command, or may be updated while the system is shut down by reloading the configuration file through use of tmloadcf
(1).
See Also
tmconfig
(1), tmloadcf
(1), ubbconfig
(5), WSL
(5)
1106
ERROR: Error receiving unsolicited message, tperrno = tperrno_val
Description
The workstation handler process experienced an error while receiving an unsolicited message. The numeric value of tperrno is also printed; this can aid in determination of a more exact cause for the problem. A numeric value of tperrno can be converted to a symbolic value by looking in the <atmi.h>
header file. In most cases, there will also be a preceding message in the userlog giving further information as to the cause of the error.
Action
Examine the userlog for any immediately preceding messages giving further information as to the cause of the error. Also examine the userlog on the site that sent the failed unsolicited message for further clues as to the cause of the error.
See Also
tperrno
(5)
1107
ERROR: Error receiving messages, tperrno = TPEOS, Uunixerr = UMSGRCV
Description
The UNIX System msgrcv
system call returned an error to the workstation handler process. A prior message in the userlog will provide more information as to the cause of the error.
Action
Examine the prior message in the userlog to determine the specific UNIX System error associated with this msgrcv
failure. If the failure is not transient and the WSH
is still active, the WSL
may need to restart this particular WSH
.
See Also
Uunix_err
(3c), tperrno
(5)
1108
ERROR: Handler received unexpected unsolicited opcode opcode_value
Description
The workstation handler process received an unsolicited message that contained an unexpected internal opcode. The opcode value is printed as part of the error message.
Action
Contact BEA Customer Support.
1109
ERROR: Failed to process broadcast message
Description
The workstation handler process received a broadcast message to be forwarded to the appropriate workstation client(s). However, it was unable to process this message for forwarding to the workstation client(s).
Action
A previous message in the userlog may indicate a more precise cause of the error and indicate a corrective action to take. The workstations associated with this workstation handler did not receive the broadcast message sent to them. Depending on the particular situation, these workstations may need to be informed of the broadcast in another way.
1110
ERROR: Couldn't change to client context context_number, continuing
Description
The Workstation Handler encountered an error switching to the context of a client when dropping all connections during shutdown.
Action
The connection is ignored. Contact BEA Customer Support.
1111
ERROR: Sending of broadcast message to client failed
Description
The workstation handler process received a broadcast message to be forwarded to the appropriate workstation client(s). However, it was unable to process this message for forwarding to one of the workstation clients. Often, this is due to a network error.
Action
Make use of network management utilities to determine if any networking problems exist between the machine on which the WSH
process is running and its associated workstation client. Also, examine the userlog to see if any immediately preceding entries give a more detailed explanation for the error.
1112
ERROR: Failed to process notification message
Description
The workstation handler process received a notification message to be forwarded to a workstation client. However, it was unable to process this message for forwarding to the workstation client.
Action
If a prior message in the userlog provides further explanation for the cause of the problem, follow the recommendations listed for that message. Otherwise, contact BEA Customer Support.
1113
ERROR: Couldn't change to client context context_number, continuing
Description
The Workstation Handler encountered an error switching to the context of a client when dropping all connections during shutdown.
Action
The connection is ignored. Contact BEA Customer Support.
1114
ERROR: Sending of notification message to client failed
Description
The workstation handler process received a notification message to be forwarded to a workstation client. However, it was unable to process this message for forwarding to the workstation client. Often, this is due to a network error.
Action
Make use of network management utilities to determine if any networking problems exist between the machine on which the WSH
process is running and its associated workstation client. Also, examine the userlog to see if any immediately preceding entries give a more detailed explanation for the error.
1120
ERROR: tpchkauth() failed, tperrno = tperrno_val
Description
As part of its startup processing, the workstation handler process attempted to determine whether application authentication is required by this application configuration, but encountered an error trying to obtain this information. The numeric value of tperrno is printed as part of the error message; this may be converted to a symbolic value by examining <atmi.h>
.
Action
Examine the userlog for a prior message indicating a more exact cause of the error.
See Also
tperrno
(5)
1121
ERROR: Couldn't get administrative key for decrypting workstation client messages
Description
The process was unable to access the encoded form of the password used to create the encryption/decryption schedule employed between the workstation handler and workstation clients.
Action
Verify that the process is running under the ID of the application administrator. Also, verify that the file $APPDIR/.adm/.keydb
has not been accidentally removed and that the TUXCONFIG
file has not been corrupted. If either of these two files has been corrupted, it will be necessary to reload the TUXCONFIG
file.
1122
ERROR: Restoring message to original condition after sending failed
Description
The workstation listener or workstation handler process sent an encrypted message to a workstation client. After the send, the WSL
or WSH
tried to restore the message to its original unencrypted state, but this operation failed.
Action
Contact BEA Customer Support.
1131
ERROR: tpbroadcast() or tpnotify() failed on send, tperrno = tperrno
Description
The workstation handler that performs the tpbroadcast or tpbroadcast call on behalf of the workstation clients failed to forward the broadcast message to the (D)BBL
administrative server. The message is to be sent to the DBBL
administrative server in MP
mode and to the BBL
administrative server in SHM
mode, which in turn takes care of broadcasting the unsolicited message to the target application clients.
Action
Check the error number, tperrno, and determine why the workstation handler was not able to send the message. Most likely the (D)BBL
administrative server queue is full. In this case, change the operating system tunable parameters to increase the maximum queue size. If tperrno is set to TPESYSTEM
or TPEOS
, check the userlog for other error messages that may indicate the exact nature of the problem and the reason for this failure.
See Also
BEA TUXEDO Workstation Guide, tpbroadcast
(3c), tperrno
(5), ubbconfig
(5)
1132
ERROR: Received message of type 'type' to tpinit() call
Description
The workstation handler that performs the tpinit
call on behalf of workstation clients received a request to join a workstation client to the application. However, the message it received in conjunction with the request was not a TPINIT
buffer, but of type type. The workstation handler will therefore remove the workstation client context from the workstation handler and return an error.
Action
If the workstation clients trying to join an application pass a buffer to the workstation handler, make sure that it is a TPINIT
buffer.
See Also
BEA TUXEDO Workstation Guide, tpinit
(3c)
1133
ERROR: TPINIT information must be passed to tpinit() call in secure application
Description
Prior to performing a tpinit
on behalf of a workstation client, the workstation handler must make sure a TPINIT
structure is passed if the application requires client authentication. In this case, the TPINIT
information was not passed even though client authentication is required. The workstation handler will therefore unregister the workstation client from the Bulletin Board, remove the workstation client context from the workstation handler, and return an error. An error message, with tperrno set to TPEPERM
, is sent back to the workstation client.
Action
Make sure the workstation clients trying to join the secure application are passing the TPINIT
information to the workstation handler.
See Also
BEA TUXEDO Workstation Guide, tpinit
(3c)
1134
ERROR: Sending of reply to ticket protocol failed
Description
The workstation handler failed to send the ticket reply back to the workstation client. The workstation handler will therefore unregister the workstation client from the Bulletin Board, remove the workstation client context from the workstation handler, and return an error.
Action
Check the userlog for other error messages that may indicate the exact nature of the problem and reason for this failure.
See Also
BEA TUXEDO Workstation Guide
1135
ERROR: Invalid client name given 'cltname'.
Description
While processing a workstation client's request to join the application, an invalid client name, cltname, was found in the TPINIT
buffer. The value sysclient is reserved by the system for the cltname field.
Action
Make sure the workstation client does not use sysclient
as a client name.
See Also
BEA TUXEDO Workstation Guide, tpinit
(3c)
1136
WARN: Invalid notification option given 0xoption, reset to TPU_IGN.
Description
While processing a workstation client's request to join the application, an invalid notification option, option, was found in the TPINIT
buffer flags field. For client notification, the possible values for flags are as follows: TPU_SIG
, TPU_DIP
, or TPU_IGN
.
Action
Make sure the client notification value in the TPINIT
buffer flags field is set correctly for the workstation client that failed to join the application.
See Also
BEA TUXEDO Workstation Guide, tpinit
(3c)
1137
ERROR: Invalid length for TPINIT structure given
Description
While processing a workstation client's request to join the application, an invalid data length was found in the TPINIT
buffer datalen field. The length must be greater than or equal to zero.
Action
Make sure the data length value in the TPINIT
buffer datalen field is set correctly for the workstation client that failed to join the application.
See Also
BEA TUXEDO Workstation Guide, tpinit
(3c)
1138
ERROR: Failed to update registry table information
Description
The workstation handler failed to update the workstation client information in the Bulletin Board's registry table. The workstation handler will therefore unregister the workstation client from the Bulletin Board, remove the workstation client context from the workstation handler, and return an error.
Action
Check the userlog for other error messages that may indicate the exact nature of the problem and reason for this failure.
See Also
BEA TUXEDO Workstation Guide, tpinit
(3c)
1139
ERROR: Failed to send message to authentication server, tperrno = tperrno_val
Description
The workstation handler failed to send the TPINIT
information to the authentication server. The call to tpacall failed with tperrno set to tperrno_val. This failure will cause the workstation handler to return an error to the workstation client with tperrno set to TPEPERM
.
Action
Check the error number, tperrno_val, and determine why the call to the authentication server failed. Most likely, the authentication server is not booted. In this case, boot the authentication server. If tperrno_val is set to TPESYSTEM
or TPEOS
, check the userlog for other error messages that may indicate the exact nature of the problem and the reason for this failure.
See Also
BEA TUXEDO Workstation Guide, tpinit
(3c), tpacall
(3c), tperrno
(5)
1140
WARN: tpbroadcast() or tpnotify() encountered blocking condition
Description
The workstation handler failed to send an unsolicited message due to a blocking condition. The workstation handler is responsible for sending to the (D)BBL
administrative server a request to forward unsolicited message on behalf of the workstation client. The request was not sent because of an existing blocking condition on the (D)BBL
administrative server queue.
Action
Most likely a system limit has been reached. You may wish to change the operating system tunable parameters related to the maximum size of a queue.
See Also
BEA TUXEDO Workstation Guide, tpbroadcast
(3c)
1141
ERROR: Unable to assign connection request, can't create any more handlers
Description
The workstation listener failed to start a new workstation handler. This may be due to no more workstation handlers being available, an error in the formatting of the command line for the workstation handler, an error in retrieving the machine table entry for the workstation listener in the Bulletin Board, or an error executing the workstation handler.
Action
Check the userlog for other error messages that may indicate the exact nature of the problem and reason for this failure.
See Also
BEA TUXEDO Workstation Guide
1142
ERROR: For a secure application, the two-p
hase challenge/response protocol must be followed
Description
The workstation handler received a message over the network from a workstation client. No context exists for this client. When running in a secure application, the only message that can be accepted by the workstation handler from a workstation client with no context is a two-p
hase challenge/response message. This is not the case. The two-p
hase challenge/response protocol must be followed in a secure application. An error message, with tperrno set to TPEPERM
, is sent back to the workstation client.
Action
Contact BEA Customer Support.
See Also
BEA TUXEDO Workstation Guide
1143
ERROR: Failed to create encryption/decryption schedule
Description
The workstation handler failed to create an encryption/decryption schedule. The function used to create the encryption/decryption schedule is called _tpcryptinit
. It is part of an internal interface that is designed to support various methods of data encryption.
Action
This probably indicates that a BEA TUXEDO system or operating system error occurred. Check the userlog for other error messages that may indicate the exact nature of the problem and reason for this failure. _tpcryptinit
may also fail because an invalid argument was given. In this case, contact BEA Customer Support.
See Also
BEA TUXEDO Workstation Guide, encryption
(3i)
1144
ERROR: _tprandkey() failed tperrno = tperrno_val, could not generate random encryption key
Description
The workstation handler failed to create a random key conforming to the restrictions of the encryption subsystem in use. The function used to create the random key is _tprandkey
. It is part of an internal interface that is designed to support various methods of data encryption.
Action
Check the error number and determine why _tprandkey
failed. This probably indicates that a BEA TUXEDO system or operating system error occurred. Check the user log for other error messages that may indicate the exact nature of the problem and reason for this failure. _tprandkey
may also fail because an invalid argument was given. In this case, contact BEA Customer Support.
See Also
BEA TUXEDO Workstation Guide, encryption
(3i)
1145
ERROR: tpalloc() failed, tperrno = tperrno_val
Description
An attempt dynamically to allocate a buffer in the workstation handler failed. The call to tpalloc
failed with tperrno
set to tperrno_val.
Action
Check the error number and determine why tpalloc
failed. Most likely, a system limit has been reached. Change the operating system tunables to increase the amount of space a process is allowed dynamically to allocate.
See Also
BEA TUXEDO Workstation Guide, tpalloc
(3c), tperrno
(5)
1146
ERROR: Sending of reply to challenge call to client failed
Description
The workstation handler failed to send the challenge reply back to the workstation client. The workstation handler will therefore unregister the workstation client from the Bulletin Board, remove the workstation client context from the workstation handler, and return an error.
Action
Check the userlog for other error messages that may indicate the exact nature of the problem and reason for this failure.
See Also
BEA TUXEDO Workstation Guide
1147
ERROR: Protocol error, can't process tpinit() request before performing security protocol
Description
The workstation handler in a secure application received a request to perform a tpinit
on behalf of a workstation client before performing the security protocol. The workstation handler will therefore unregister the workstation client from the Bulletin Board, remove the workstation client context from the workstation handler, and return an error.
Action
Check the userlog for other error messages that may indicate the exact nature of the problem and reason for this failure.
See Also
BEA TUXEDO Workstation Guide, tpinit
(3c)
1148
ERROR: Processing of message to be sent to client failed
Description
The workstation handler failed to send a message to the workstation client. The failure occurred in a low level routine that performs all manipulations for the message send. This includes pre-send, encoding, and post-send work. The message being sent from the workstation handler to the workstation client had to do with the workstation client trying to join the application. During this phase, all messages are encrypted when they are sent across the network. The messages may also be encoded if the machines are not of the same type. The workstation handler failed to encrypt the message.
Action
Check the userlog for other error messages that may indicate the exact nature of the problem and reason for this failure.
See Also
BEA TUXEDO Workstation Guide
1149
ERROR: Validation of TPINIT information failed
Description
The workstation handler failed to validate the TPINIT
structure identifying the connecting client against an uninterpreted ticket structure identifying the security agent's opinion of the client to determine if the connecting client should be granted access to the application. The function used to perform the validation is _tpvalidate
(3i). It is part of an internal interface that is designed to support various methods of application authentication.
Action
This probably indicates that the security ticket and tpinit information do not match, and the user should not be allowed to join the application. It can also mean that a BEA TUXEDO system or operating system error occurred. Check the userlog for other error messages that may indicate the exact nature of the problem and reason for this failure. _tpvalidate
may also fail because an invalid argument was given. In this case, contact BEA Customer Support.
See Also
BEA TUXEDO Workstation Guide, security(3i)
1150
ERROR: Incorrect timestamp value sent by workstation client
Description
The workstation handler failed to validate the ticket information passed to it by a workstation client. The ticket information passed from the workstation client to the workstation handler does not match the timestamp information stored in the workstation handler.
Action
Check the userlog for other error messages that may indicate the exact nature of the problem and reason for this failure.
See Also
BEA TUXEDO Workstation Guide
1152
ERROR: Memory allocation failure
Description
An attempt dynamically to allocate memory from the operating system using malloc
failed while validating the ticket information passed to the workstation handler by the workstation client.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used be a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
See Also
BEA TUXEDO Workstation Guide
1153
ERROR: Could not obtain session key from ticket
Description
The workstation handler failed to retrieve a session key from a ticket in a secure application while trying to validate the ticket information passed to it by a workstation client. The function used to retrieve the session key is _tpsessionkey
. It is part of an internal interface that is designed to support various methods of authentication.
Action
This probably means that a BEA TUXEDO system or operating system error occurred. Check the userlog for other error messages that may indicate the exact nature of the problem and reason for this failure. _tpsessionkey
may also fail because an invalid argument was given or the ticket could not be processed because the workstation client was denied permission for an implementation specific reason. In this case, contact BEA Customer Support.
See Also
BEA TUXEDO Workstation Guide, security(3i)
1154
ERROR: Failed to encrypt ticket information
Description
The workstation handler failed to encrypt data according to a schedule while accepting a challenge and timestamp value that is to be used to verify that the request is valid. The function used to encrypt data is _tpcrypt
. It is part of an internal interface that is designed to support various methods of encryption.
Action
This probably means that a BEA TUXEDO system or operating system error occurred. Check the userlog for other error messages that may indicate the exact nature of the problem and reason for this failure. _tpcrypt
may also fail because an invalid argument was given. In this case, contact BEA Customer Support.
See Also
BEA TUXEDO Workstation Guide, encryption(3i)
1156
ERROR: Decryption of challenge request failed
Description
While a workstation client was attempting to join the application, decrypting the challenge request message failed.
Action
Contact BEA Customer Support.
1157
ERROR: Encryption of challenge request failed
Description
While a workstation client was attempting to join the application, encrypting the challenge request message failed.
Action
Contact BEA Customer Support.
1158
ERROR: Couldn't create encryption/decryption schedule
Description
While a workstation client was attempting to join the application, the encryption or decryption schedule could not be created.
Action
Contact BEA Customer Support.
1159
ERROR: Failed to encode/decode establish connection request message
Description
While a workstation client was attempting to join the application, encoding or decoding of the establish connection request message failed.
Action
Contact BEA Customer Support.
1160
ERROR: Decryption of challenge reply failed
Description
While a workstation client was attempting to join the application, decrypting the challenge reply message failed.
Action
Contact BEA Customer Support.
1161
ERROR: Encryption of challenge reply failed
Description
While a workstation client was attempting to join the application, encrypting the challenge reply message failed.
Action
Contact BEA Customer Support.
1162
ERROR: Encoding/decoding of ticket request failed
Description
While a workstation client was attempting to join the application, encoding or decoding the ticket request message failed.
Action
Contact BEA Customer Support.
1163
ERROR: Encoding/decoding of ticket request failed
Description
While a workstation client was attempting to join the application, encoding or decoding the ticket request message failed.
Action
Contact BEA Customer Support.
1164
ERROR: Decryption of TPINIT buffer failed
Description
While a workstation client was attempting to join the application, decrypting the TPINIT
message failed.
Action
Contact BEA Customer Support.
1165
ERROR: Encoding/decoding of TPINIT buffer failed
Description
While a workstation client was attempting to join the application, encoding or decoding the TPINIT
message failed.
Action
Contact BEA Customer Support.
1166
ERROR: Encryption of TPINIT buffer failed
Description
While a workstation client was attempting to join the application, encrypting the TPINIT
message failed.
Action
Contact BEA Customer Support.
1167
ERROR: Unknown work station message to process
Description
While a workstation client was attempting to join the application, an unknown message type was encountered for processing.
Action
Contact BEA Customer Support.
1168
ERROR: Tried to process unexpected message opcode 0xcode
Description
While a workstation client was attempting to join the application, an unknown message type was encountered for processing.
Action
Contact BEA Customer Support.
1169
ERROR: Expected numeric argument to -D option
Description
An invalid argument was passed to the workstation listener command line option. The argument to the -D
option needs to be numeric. This error will cause the workstation listener not to be booted.
Action
Make sure the argument to the -D
option is numeric.
See Also
BEA TUXEDO Workstation Guide, WSL
(5)
1170
ERROR: Expected numeric argument to -M option
Description
An invalid argument was passed to the workstation listener command line option. The argument to the -M
option needs to be numeric. This error will cause the workstation listener not to be booted.
Action
Make sure the argument to the -M
option is numeric.
See Also
BEA TUXEDO Workstation Guide, WSL
(5)
1171
ERROR: Expected numeric argument to -m option
Description
An invalid argument was passed to the workstation listener command line option. The argument to the -m
option needs to be numeric. This error will cause the workstation listener not to be booted.
Action
Make sure the argument to the -m
option is numeric.
See Also
BEA TUXEDO Workstation Guide, WSL
(5)
1172
ERROR: Expected numeric argument to -t option
Description
An invalid argument was passed to the workstation listener command line option. The argument to the -t
option needs to be numeric. This error will cause the workstation listener not to be booted.
Action
Make sure the argument to the -t
option is numeric.
See Also
BEA TUXEDO Workstation Guide, WSL
(5)
1173
ERROR: Bad -t option
Description
An invalid argument was passed to the workstation listener command line option. The argument to the -t
option needs to be in the range 1 to 255 inclusive. This error will cause the workstation listener not to be booted.
Action
Make sure the argument to the -t
option is in the allowable range.
See Also
BEA TUXEDO Workstation Guide, WSL
(5)
1174
WARN: Disconnecting listener connection to workstation, connection timed out
Description
The workstation listener will scan its handler table and time out any connections that are overdue, restart any dead handlers, and allocate any blocked connection requests to a handler that is available. When scanning this table, the workstation listener found a handler that was waiting for a connection that had timed out. The workstation listener went ahead and forced the connection closed.
Action
The workstation listener -t
command line option can be used to specify the amount of time that should be allowed for a workstation client to complete initialization processing through the workstation handler before being timed out by the workstation listener. This number may need to be increased to avoid frequent timeouts.
See Also
BEA TUXEDO Workstation Guide, WSL
(5)
1175
WARN: Disconnecting listener connection to workstation, request timed out
Description
The workstation listener will scan its handler table and time out any connections that are overdue, restart any dead handlers, and allocate any blocked connection requests to a handler that is available. When scanning this table, the workstation listener found a blocked connection request that had not been passed to an available handler. Since the time to assign a handler expired, the workstation listener went ahead and forced the connection closed.
Action
This probably indicates that the number of workstation clients that need to join the application can not be supported by the existing configuration. The workstation listener command line options should be reset to support a larger number of workstation clients. The workstation listener -m
, -M
, and -x
options should be used to that effect.
See Also
BEA TUXEDO Workstation Guide, WSL
(5)
1176
ERROR: Sending of reply to tpconnect() call to client failed
Description
An attempt to send an acknowledgment of a tpconnect
request to the Workstation Client has failed.
Action
This is an internal message. This failure indicates a problem with the network, with the Workstation, or with the Workstation client process. Contact BEA Customer Support.
1177
ERROR: Sending of reply to tpdiscon() call to client failed
Description
An attempt to send an acknowledgment of a tpdiscon
request to the Workstation Client has failed.
Action
This is an internal message. This failure indicates a problem with the network, with the Workstation, or with the Workstation client process. Contact BEA Customer Support.
1178
ERROR: Sending of reply to tpsend() call to client failed
Description
An attempt to send an acknowledgment of a tpbroadcast request to the Workstation Client has failed.
Action
This is an internal message. This failure indicates a problem with the network, with the Workstation, or with the Workstation client process. Contact BEA Customer Support.
1179
ERROR: Unrecognized opcode: opcode
Description
A message was received in the Workstation Handler requesting an operation that is not known.
Action
This is an internal message. This failure indicates a problem with the network, with the Workstation, or with the Workstation client process. It could indicate the use of newer workstation client software with an older Workstation Handler. Contact BEA Customer Support.
1180
ERROR: Sending of reply to tpconnect() call to client failed
Description
An attempt to send an acknowledgment of a tpconnect
request to the Workstation Client has failed.
Action
This is an internal message. This failure indicates a problem with the network, with the Workstation, or with the Workstation client process. Contact BEA Customer Support.
1182
ERROR: Invalid -T option = num
Description
The -T
command line option for the workstation listener WSL
had an invalid argument. The value must be greater than or equal to 0 and less than 70409299.
Action
Reconfigure the CLOPT
for the WSL
and reboot the process.
1183
ERROR: Expected numeric argument to -T option
Description
The -T
command line option for the workstation listener WSL
had a non-numeric argument.
Action
Reconfigure the CLOPT
for the WSL
and reboot the process.
1185
INFO: Userid: [user], Clientid: [client] timed out due to inactivity
Description
A workstation client attached to the application has been invalid for longer than the configured timeout value, specified via the -T
command line option. The associated user name and client name are printed.
Action
No action required.
1186
ERROR: Cannot convert message with unknown protocol num
Description
The workstation Handler, WSH
, received a message from a workstation client with an unknown protocol number, num.
Action
Check that the WSTYPE
environment variable is correctly set so that encoding is done if necessary. Validate that the correct workstation software is being used with the associated WSH
. You may need to contact BEA Customer Support.
1187
ERROR: Cannot convert message from protocol num1 to num2
Description
The workstation Handler, WSH
, received a message to or from a workstation client with a protocol version that cannot be converted.
Action
Contact BEA Customer Support.
1188
ERROR: Unrecognized message format, release num
Description
The workstation Listener, WSL
, received a connection message from a workstation client with an unknown protocol number, num.
Action
Check that the WSTYPE
environment variable is correctly set so that encoding is done if necessary. Validate that the correct workstation software is being used with the associated WSL
. You may need to contact BEA Customer Support.
1190
INFO: Reestablished network address string
Description
A previously suspended workstation listener process has been unsuspended and has reestablished its network address.
Action
Informational message, no action required.
See Also
Administering the BEA TUXEDO System, MIB
(5), WS_MIB
(5)
1191
INFO: Network address disabled
Description
A workstation listener process has been suspended and has disabled its listening network address to disallow further incoming connections.
Action
Informational message, no action required.
See Also
Administering the BEA TUXEDO System, MIB
(5), WS_MIB
(5)
1192
INFO: Abortively disconnecting workstation client user[usr], client[clt]
Description
A workstation handler is disconnecting the virtual circuit associated with a particular workstation client (usr>/clt) because of an administrative request to set the client state to DEAD
.
Action
Informational message, no action required.
1193
WARN: Obsolete option used, -t
Description
An obsolete option, -t
, was specified in the command line options for a workstation listener server. This option is being replaced by the -I
option, which takes a client initialization timeout value in seconds instead of the SCANUNIT
multiple expected for the -t
option.
Action
The -t
option may be removed in future releases; therefore, the administrator should plan to transition workstation listener specifications to use the -I
option. Since the administrator may not know at configuration time if the site where the listener may be run supports the -I
option yet, the current implementation allows both on the command line and will use the last option found on the command line. Therefore, the recommended action is to add a corresponding -I
option at the end of the command line options for the workstation listener. In environments where there are no pre-release 6.0 BEA TUXEDO system sites, the -t
option may be discarded entirely.
See Also
Administering the BEA TUXEDO System, MIB
(5), WSL
(5), WS_MIB
(5)
1194
ERROR: Invalid or non-numeric value specified for -I
option, val
Description
The workstation listener command line options contained an invalid value for the -I
option. This option requires a numeric value between 1 and 32,767 inclusive.
Action
Correct the value in the command line options and reboot the server.
See Also
Administering the BEA TUXEDO System, MIB
(5), WSL
(5), WS_MIB
(5)
1195
WARN: Failed to reestablish network address string
Description
A previously suspended workstation listener server was administratively unsuspended but could not reestablish its network address.
Action
Failure to reestablish the network address is usually caused either by a failure of the network drivers on the machine to clear the previously held network address or by another process claiming the network address while the listener was suspended. In the former case, the network address will eventually be released by the system and the workstation listener will reestablish its network address through its periodic retry mechanism; therefore, no action is required in this case. In the latter case, local commands may be used to determine what process and user are occupying the network address, and they should be asked to relinquish the address.
See Also
Administering the BEA TUXEDO System, netstat
(1), MIB
(5), WS_MIB
(5)
1196
INFO: Terminating handlers in preparation for shutdown
Description
The workstation listener is shutting down and is about to terminate its associated workstation handler processes in preparation.
Action
Informational message, no action required.
See Also
Administering the BEA TUXEDO System, tmshutdown
(1), MIB
(5), WS_MIB
(5)
1197
INFO: Exiting system
Description
The workstation listener has completed its shutdown and is exiting the system.
Action
Informational message, no action required.
See Also
Administering the BEA TUXEDO System, WSL
(5)
1199
WARN: .SysClientDied: User usrname on LMID client died
Description
This message indicates that the client specified above exited the application without doing a tpterm
(). A complete listing of the current attributes of the client are sent in the posted buffer. In the normal way, the clients should do a tpterm
() before exiting the application.
Action
This is an informational message.
See Also
EVENT_MIB
(5), TM_MIB
(5)