Installation

Understanding the Server

Installation Task Overview

Server Overview

Front Panel Components (Installation)

Rear Panel Components (Installation)

Confirming Server and Site Specifications

Physical Specifications

Minimum Clearance for Service Access

AC and DC Power Supply Specifications

Input Power Information

Overcurrent Protection Requirements

DC Power Source, Power Connection, and Grounding Requirements

Environmental Requirements

Acoustic Noise Emissions

Airflow Clearance

Preparing for Installation

Shipping Kit Inventory

Handling Precautions

ESD Precautions

Tools Needed for Installation

Optional Components

Rack Cautions

Stabilize the Rack

Installing the Server in a 4-Post Rack

Installing the Standard 19-Inch Hardmount Kit (4-Post Rack)

Installing the 19-Inch Sliding-Rail Kit (4-Post Rack)

Installing the 600-mm Hardmount Kit (4-Post Rack)

Installing the Server in a 2-Post Rack

Installing the 19-Inch Hardmount Kit (2-Post Rack)

Installing the 19-Inch Sliding-Rail Kit (2-Post Rack)

Installing the 23-Inch Hardmount Kit (2-Post Rack)

Connecting Cables

Connecting Data and Management Cables

Identifying Ports

Powering On the Server the First Time

Connect AC Power Cords

Assembling DC Power Cords and Applying DC Power

Power On the Host for the First Time

OS Installation

Choosing an OS Installation Method

OS Installation Task Map (Oracle Solaris)

OS Installation Task Map (Oracle VM)

OS Installation Task Map (Linux)

OS Installation Task Map (VMware ESXi)

OS Installation Task Map (Windows)

Supported OS Versions and Documentation

Oracle Linux Support Kernel

Understanding Installation Methods

Configuring the Preinstalled Oracle Solaris OS

Preinstalled OS RAID Limitations

Configuration Worksheet (Oracle Solaris)

Configure the Preinstalled Oracle Solaris OS

Configuring the Preinstalled Oracle VM 3. 0 Software

Configuration Worksheet (Oracle VM Server)

Configure the Preinstalled Oracle VM 3.0 OS

Oracle VM 3.0 Overview

Preparing to Install an OS

Selecting the Console Display

Selecting the Boot Media

Preparing Your PXE Environment

Accessing Installation Utilities

Setting Up BIOS

Configuring RAID

HBA and RAID Support

RAID Configuration Requirements

Post-Installation RAID Volume Creation

Configure RAID (OSA)

Configuring RAID Volumes (LSI BIOS Utilities)

Installing a Supported OS

Install an OS (OSA)

Installing an OS (Media)

Install an OS (Media)

Install HBA Drivers (Windows)

Install an OS (PXE)

Performing Post-Installation Tasks

(Optional) Assign Boot Drive Priorities

Oracle VM Post-Installation Information

Performing Linux Post-Installation Tasks

Performing VMware ESXi Post-Installation Tasks

Performing Windows Post-Installation Tasks

Administration

Understanding Administration Resources

Common Administration Tools

Oracle ILOM Overview

BIOS Overview (Administration)

OSA Overview

HMP

Hardware RAID Administration Tools

Multiple Server Management Tools

Accessing Administration Tools

Accessing Oracle ILOM

Accessing BIOS

Accessing OSA

Access Add-On Card Configuration Utilities (BIOS)

Controlling the Server

Controlling the Power State

Change Telco Alarm States Manually

Configuring Power-On and Boot Options

Configuring Power-On Policies

Selecting a Boot Device

Configuring Oracle ILOM

Change the Oracle ILOM Root Password (Oracle ILOM CLI)

Recover the Oracle ILOM Root Password

Configuring Oracle ILOM (Oracle ILOM Web Interface)

Configuring the SP and Oracle ILOM (BIOS)

Configure the SP and Oracle ILOM (OSA)

Configure the Enhanced PCIe Cooling Mode Policy (Oracle ILOM CLI)

Configuring BIOS

Resetting the BIOS to Default Settings

Configuring Legacy Option ROM Allocation

Configuring I/O Resource Allocation

Configuring Devices in BIOS

Enabling or Disabling OSA

Disable OSA

Enable OSA

Monitoring the Server

Obtain the Server Serial Number

Locate the Server (Oracle ILOM Web Interface)

Obtaining Server Information

Monitoring the Server Health (Oracle ILOM Web Interface)

Understanding SNMP Traps

Updating the Firmware and Software

Update to a New OSA Release

Obtain and Update Firmware (OSA)

Restore OSA

Mounting the Oracle System Assistant USB Flash Drive

Obtaining Updated Software

Requesting Updates on Physical Media

Service

Identifying Components

Component Locations (Storage, Power, and Fans)

Component Locations (Motherboard, Memory, and PCIe3 Cards)

Front Panel Components (Service)

Rear Panel Components (Service)

Detecting and Managing Faults

Understanding Diagnostics

Interpreting Diagnostic LEDs

Troubleshooting (Oracle ILOM /SP Targets)

BIOS POST Event Messages

Troubleshooting (Oracle ILOM /System Targets)

Displaying Faulty Components

Troubleshooting (Oracle ILOM Legacy Targets)

Troubleshooting (Pc-Check)

Preparing for Service

Safety Information

Tools Needed for Service

Filler Panels

Find the Server Serial Number

Component Service Task Reference

Locate the Server

Removing Power From the Server

Accessing Internal Components

Remove the Fan Tray

Raise the Drive Cage to the Service Position

Remove the Air Duct

Remove the PDB Duct

Servicing the Filter

Remove the Filter

Install the Filter

Servicing Drives

Drive Configuration

Drive LEDs

Locate a Faulty Drive

Remove a Drive

Install a Drive

Verify a Drive

Servicing the DVD Drive

Remove the DVD Drive

Install the DVD Drive

Servicing Power Supplies

Power Supply LEDs

Locate a Faulty Power Supply

Remove a Power Supply

Install a Power Supply

Verify a Power Supply

Servicing Fan Modules

Fan Module LEDs

Locate a Faulty Fan Module

Remove a Fan Module

Install a Fan Module

Verify a Fan Module

Servicing Risers

Riser Configuration

Locate a Faulty Riser

Remove a Riser

Install a Riser

Verify a Riser

Servicing PCIe3 Cards

PCIe3 Card Configuration

Locate a Faulty PCIe3 Card

Remove a PCIe3 Card (Risers 1 and 2)

Remove a PCIe3 Card (Riser 3)

Install a PCIe3 Card (Risers 1 and 2)

Install a PCIe3 Card (Riser 3)

Verify a PCIe3 Card

Servicing the Battery

Remove the Battery

Install the Battery

Servicing the USB Drive

USB Drive LED

Remove the USB Drive

Install the USB Drive

Servicing Cables

Cable Configuration

Remove the Drive Signal Cable

Install the Drive Signal Cable

Remove the Drive Power Cable

Install the Drive Power Cable

Remove the DVD SATA Cable

Install the DVD SATA Cable

Remove the PDB Signal Cable

Install the PDB Signal Cable

Servicing the Drive Backplane

Drive Backplane Configuration

Determine if the Drive Backplane Is Faulty

Remove the Drive Backplane

Install the Drive Backplane

Verify the Drive Backplane

Servicing DIMMs

DIMM Configuration

Locate a Faulty DIMM

Remove a DIMM

Install a DIMM

Verify a DIMM

Servicing CPUs

CPU Configuration

Locate a Faulty CPU

CPU Tool

Remove a CPU

Install a CPU

Servicing the LED Board

Determine if the LED Board Is Faulty

Remove the LED Board

Install the LED Board

Verify the LED Board

Servicing the USB Board

Remove the USB Board

Install the USB Board

Servicing the Motherboard

Determine if the Motherboard Is Faulty

Remove the Motherboard

Install the Motherboard

Verify the Motherboard

Servicing the PDB

Determine if the PDB Is Faulty

Remove the PDB

Install the PDB

Verify the PDB

Returning the Server to Operation

Install the PDB Duct

Install the Air Duct

Secure the Drive Cage

Install the Fan Tray

Install the Top Cover

Connect Power Cords

Power On the Server (Oracle ILOM)

Power On the Server (Power Button)

Glossary

Index

Install HBA Drivers (Windows)

During the Windows OS installation, perform these steps to ensure that the drivers for your HBA are installed.


Note - If you used OSA to install the Windows OS, you do not need to perform this procedure because OSA installs the required HBA drivers.


  1. In the Installation Type window, click Custom (Advanced).

    The Where Do You Want to Install Windows window appears.


    image:Where do want to install Windows screen
  2. Perform one of these tasks:
    • If you do not see any storage targets listed, and a Sun Storage SAS PCIe RAID HBA option is configured on your server, click Load Driver, then proceed to Step 3.

    • If you see the storage target where you want to install the OS but want to change the default partition settings associated with that target, select the target, click Drive Options (advanced), then proceed to Step 4.

  3. In the Load Drive dialog box, perform these steps:
    image:Load Driver dialog
    1. Ensure that the drivers are accessible according to the installation method chosen.

      See Selecting the Boot Media.

      For example:

      • Drivers are on a disk mounted as a device from the Oracle ILOM Remote Console.
      • Storage drivers are on a local physical storage media such as the OSA USB drive (if installed), which is mounted internally in the server's chassis, a CD/DVD, or virtual media mounted from the Oracle ILOM Remote Console.
    2. In the Load Driver dialog box, click Browse to navigate to the appropriate driver media folder on the OSA USB drive.
      Supported HBA Option Number
      Folder
      Driver Required During Installation
      SG-SAS6-R-INT-Z or

      SG-SAS6-R-EXT-Z

      windows/w2k8/drivers/LSI-HBA-MegaSAS2
      LSI MegaRAID SAS 92xx-xx
      SG-SAS6-INT-Z or

      SG-SAS6-EXT-Z

      windows/w2k8/drivers/LSI-HBA-MPT2
      LSI Adapter SAS 2008 Falcon
    3. In the Browse for Folder dialog box, select the appropriate driver, then click OK to load the driver.

      The selected driver appears in the Select the Driver to Be Installed window.

      For example:


      image:HBA option selection of LSI MegaRAID SAS 9261-8i driver to be installed dialog
    4. In the Select the Driver to Be Installed window, click Next to install the driver.

      The Where Do You Want to Install Windows window appears.


      image:Drive Target Selected

      Note - If you previously removed or unmounted the Windows OS installation media to load the drivers from the internal OSA USB drive, you might see this message: “Windows Cannot be installed to this disk.” If this message appears, insert or re-mount the Windows installation media, then click Refresh.


    5. In the Where Do You Want to Install Windows window, perform one of these actions:
      • If any partitions exist on your target drive, allow the setup to create the appropriate partitions. Go to Step 4.
      • Select the storage target listed and click Next to install the OS, then proceed to Step 5.
  4. In the lower portion of the Where Do You Want to Install Windows window, perform these steps:
    image:Partition Drive Options
    1. Click Delete to delete the selected storage target existing partition configuration.

      A confirmation window appears.

    2. Click OK to confirm the partition deletion.
    3. If any additional partitions exist on the target drive, repeat Step a and Step b.
    4. Click Next to install the OS to the selected storage target.

    The Windows installation program begins and will reboot the server multiple times during the installation process.

  5. Change the user password when prompted.

    When the installation is complete, Windows starts and prompts you to change the user password.

  6. In the User Password dialog box, click OK and set up the initial user login account.

    After the initial user account is created, the Windows OS desktop appears.

  7. Perform post-installation tasks.

    See Performing Post-Installation Tasks.

Related Information