Content starts here

System Messages: LIBTMIB Catalog 500-599

Previous Next

505


ERROR: Cannot set TA_AUTOTRAN to Y if the NO_XA option is on

Description

A SET operation on TA_AUTOTRAN to "Y" is not allowed with a NO_XA OPTIONS set for the application in the tuxconfig.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


506


ERROR: Cannot set TA_AUTOTRAN to Y if the NO_XA option is on

Description

A SET operation on TA_AUTOTRAN to "Y" is not allowed with a NO_XA OPTIONS set for the application in the tuxconfig.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


507


ERROR: Cannot set TA_AUTOTRAN to Y if the NO_XA option is on

Description

A SET operation on TA_AUTOTRAN to "Y" is not allowed with a NO_XA OPTIONS set for the application in the tuxconfig.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


508


ERROR: Cannot set NO_XA option because LMID lmid has a configured TLOGDEVICE

Description

A SET operation on TA_OPTIONS to "NO_XA" is not allowed because the LMID lmid has been configured with a TLOGDEVICE.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


509


ERROR: Cannot set NO_XA option because LMID lmid has a configured TLOGNAME

Description

A SET operation on TA_OPTIONS to "NO_XA" is not allowed because the LMID lmid has been configured with a TLOGNAME.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


510


ERROR: Cannot set NO_XA option because LMID lmid has a configured TLOGSIZE

Description

A SET operation on TA_OPTIONS to "NO_XA" is not allowed because the LMID lmid has been configured with a TLOGSIZE.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


511


ERROR: Cannot set NO_XA option because GROUP group has a configured OPENINFO string

Description

A SET operation on TA_OPTIONS to "NO_XA" is not allowed because the GROUP group has been configured with an OPENINFO string.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


512


ERROR: Cannot set NO_XA option because GROUP group has a configured CLOSEINFO string

Description

A SET operation on TA_OPTIONS to "NO_XA" is not allowed because the GROUP group has been configured with an CLOSEINFO string.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


513


ERROR: Cannot set NO_XA option because GROUP group has a configured TMSCOUNT

Description

A SET operation on TA_OPTIONS to "NO_XA" is not allowed because the GROUP group has been configured with a TMSCOUNT.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


514


ERROR: Cannot set NO_XA option because GROUP group has a configured TMSNAME

Description

A SET operation on TA_OPTIONS to "NO_XA" is not allowed because the GROUP group has been configured with a TMSNAME.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


515


ERROR: Cannot set NO_XA option because SERVICE service is configured AUTOTRAN

Description

A SET operation on TA_OPTIONS to "NO_XA" is not allowed because the SERVICE service has been configured with AUTOTRAN set to "Y".

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


516


ERROR: Cannot set NO_XA option because INTERFACE interface is configured AUTOTRAN

Description

A SET operation on TA_OPTIONS to "NO_XA" is not allowed because the INTERFACE interface has been configured with AUTOTRAN set to "Y".

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


517


ERROR: Can not set TA_TLOGDEVICE when the NO_XA option is set

Description

A SET operation on TA_TLOGDEVICE is not allowed with a NO_XA OPTIONS set for the application in the tuxconfig.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


518


ERROR: Can not set TA_TLOGNAME when the NO_XA option is set

Description

A SET operation on TA_TLOGNAME is not allowed with a NO_XA OPTIONS set for the application in the tuxconfig.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


519


ERROR: Can not set TA_TLOGSIZE when the NO_XA option is set

Description

A SET operation on TA_TLOGSIZE is not allowed with a NO_XA OPTIONS set for the application in the tuxconfig.

Action

These 2 settings are incompatable.

See Also

TM_MIB(5) and ubbconfig(5)


520


ERROR: Invalid service name (svc) presented to /Admin service

Description

An invalid service name svc has been presented to the /AdminAPI service processing routine.

Action

Correct the requested service on the request.

See Also

MIB(5), TM_MIB(5)


521


ERROR: Invalid operation (op) specified for /Admin request

Description

Missing or invalid value for TA_OPERATION included in /AdminAPI request buffer. This is a required input parameter on all /AdminAPI requests and must have a value of GET, SET or GETNEXT.

Action

Correct the input buffer to include an appropriate value for the TA_OPERATION attribute.

See Also

MIB(5), TM_MIB(5)


522


ERROR: Invalid class specified

Description

The TA_CLASS value for an /AdminAPI request is either invalid (does not match any classes known by the system) or is missing.

Action

Examine the original input buffer (also contained with the reply buffer) to see if the TA_CLASS value is missing or invalid. If it is missing, then add the appropriate class value to the buffer. If it is invalid, then check reference pages and spelling and correct the class name in the request.

See Also

MIB(5), TM_MIB(5)


523


ERROR: /Admin service input buffer not FML32

Description

An /AdminAPI request was received that was not an FML32 typed buffer. /AdminAPI services process only FML32 typed buffers.

Action

Change the administrative program to generate FML32 requests only.

See Also

Fintro(3fml), MIB(5), TM_MIB(5)


524


ERROR: /Admin service input buffer does not include class

Description

An administrative request received by an /AdminAPI service did not contain a TA_CLASS value. A TA_CLASS value is required as defined in MIB(5).

Action

Correct the request message to include a TA_CLASS value.

See Also

Fintro(3fml), MIB(5), TM_MIB(5)


525


ERROR: Failed to update FML and VIEW environment variables

Description

/AdminAPI service initialization for the administrative process logging the message failed because the indicated environment variables could not be dynamically updated to include references to directories and files necessary for /AdminAPI processing. This error is caused by a failure to allocate sufficient memory from the system.

Action

Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.

See Also

malloc(3) in UNIX reference manuals, MIB(5), TM_MIB(5)


526


ERROR: Memory allocation failure

Description

An attempt dynamically to allocate memory from the operating system using malloc failed while adding FML and VIEW environment variables to the process memory.

Action

Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.

See Also

malloc(3) in UNIX reference manuals, MIB(5), TM_MIB(5)


 Back to Top Previous Next