The tables in this appendix show the in-rack cable connections for Sun Fire X4270 M2-based Oracle Big Data Appliance racks. This appendix contains the following sections:
Figure D-1 shows the front and rear layout of an Oracle Big Data Appliance rack.
Figure D-1 Rack Layout of Oracle Big Data Appliance
A KVM switch is provided only in Sun Fire X4270 M2-based rack.
Table D-1 shows the keyboard, video, and mouse (KVM) network cabling to the servers. The cables are orange.
From Rack Unit | Component | To KVM Port |
---|---|---|
U41 |
Server 18 |
1 |
U39 |
Server 17 |
2 |
U37 |
Server 16 |
3 |
U35 |
Server 15 |
4 |
U33 |
Server 14 |
5 |
U31 |
Server 13 |
6 |
U29 |
Server 12 |
7 |
U28 |
Server 11 |
8 |
U27 |
Server 10 |
9 |
U26 |
NM2-IB leaf switch |
10 |
U25 |
KVM switch |
11 |
U19 |
KVM tray |
12 |
U18 |
Cisco switch |
13 |
U17 |
NM2-IB leaf switch |
14 |
U16 |
Server 9 |
15 |
U14 |
Server 8 |
16 |
U12 |
Server 7 |
17 |
U10 |
Server 6 |
18 |
U8 |
Server 5 |
19 |
U6 |
Server 4 |
20 |
U4 |
Server 3 |
21 |
U2 |
Server 2 |
22 |
Table D-2 shows the cable connections for the administrative Gigabit Ethernet network (Net 0). The Ethernet switch is located in rack unit 21. The cables are 10 feet long and black.
Table D-2 Administrative Gigabit Ethernet Cabling
From Rack UnitFoot 1 | Component | To Ethernet Port |
---|---|---|
U41 |
Server 18 |
1 |
U39 |
Server 17 |
3 |
U37 |
Server 16 |
5 |
U35 |
Server 15 |
7 |
U33 |
Server 14 |
9 |
U31 |
Server 13 |
11 |
U29 |
Server 12 |
13 |
U27 |
Server 11 |
17 |
U25 |
Server 11 |
21 |
U24 |
NM2-IB Switch |
45 |
U20 |
NM2-IB Switch |
46 |
U18 |
Server 10 |
25 |
U16 |
Server 9 |
29 |
U14 |
Server8 |
31 |
U12 |
Server 7 |
33 |
U10 |
Server 6 |
35 |
U8 |
Server 5 |
37 |
U6 |
Server 4 |
39 |
U4 |
Server 3 |
41 |
U2 |
NM2-IB Switch |
43 |
U1 |
Server 2 |
47 |
Footnote 1 Un is the unit location in the rack, where n is the number.
Table D-3 shows the cable connections from the servers to the Oracle ILOM switch. The Oracle ILOM ports on the servers are labeled Net Mgt and connect to the Cisco Ethernet switch located in rack unit 21.
From Rack UnitFoot 1 | Component | Ethernet Port | Cable Length | Cable Color |
---|---|---|---|---|
U41 |
Server 18 |
2 |
10 feet |
Red |
U39 |
Server 17 |
4 |
10 feet |
Red |
U37 |
Server 16 |
6 |
10 feet |
Red |
U35 |
Server 15 |
8 |
10 feet |
Red |
U33 |
Server 14 |
10 |
10 feet |
Red |
U31 |
Server 13 |
12 |
10 feet |
Red |
U29 |
Server 12 |
14 |
10 feet |
Red |
U27 |
Server 11 |
18 |
10 feet |
Red |
U25 |
Server 10 |
22 |
10 feet |
Red |
U18 |
Server 9 |
26 |
10 feet |
Red |
U16 |
Server 8 |
30 |
10 feet |
Red |
U14 |
Server 7 |
32 |
10 feet |
Red |
U12 |
Server 6 |
34 |
10 feet |
Red |
U10 |
Server 5 |
36 |
10 feet |
Red |
U8 |
Server 4 |
38 |
10 feet |
Red |
U6 |
Server 3 |
40 |
10 feet |
Red |
U4 |
Server 2 |
42 |
10 feet |
Red |
U2 |
Server 1 |
44 |
10 feet |
Red |
PDU-A |
PDU-A |
15 |
1 meter |
White |
PDU-B |
PDU-B |
20 |
1 meter |
White |
Not applicable |
Service |
48 |
10 feet |
Blue |
Footnote 1 Un is the unit location in the rack, where n is the number.
Table D-4 shows the connections for single-phase cabling from each power distribution unit (PDU) to the power supplies in the rack. The cables terminate at PDU-A on the left and are routed to the right to enter the cable management arm (CMA). The cables are bundled in groups of four.
Table D-4 Single-Phase PDU Cabling
Rack UnitFoot 1 | PDU-A/PS-00 | PDU-B/PS-01 | Cable Length |
---|---|---|---|
U41 |
G5-6 |
G0-0 |
2 meters |
U39 |
G5-3 |
G0-3 |
2 meters |
U37 |
G5-0 |
G0-6 |
2 meters |
U35 |
G4-6 |
G1-0 |
2 meters |
U33 |
G4-4 |
G1-2 |
2 meters |
U31 |
G4-2 |
G1-4 |
2 meters |
U29 |
G3-6 |
G2-0 |
2 meters |
U27 |
G3-5 |
G2-1 |
2 meters |
U25 |
G3-3 |
G2-3 |
2 meters |
U24 |
G3-1 |
G2-5 |
2 meters |
U23 |
Not Applicable |
G3-0 |
included |
U22 |
G2-5 |
G3-1 |
1 meter |
U21 |
G3-0 |
G2-6 |
2 meters |
U20 |
G2-4 |
G3-2 |
2 meters |
U18 |
G2-2 |
G3-4 |
2 meters |
U16 |
G1-6 |
G4-0 |
2 meters |
U14 |
G2-0 |
G3-6 |
2 meters |
U12 |
G1-4 |
G4-2 |
2 meters |
U10 |
G1-2 |
G4-4 |
2 meters |
U8 |
G1-0 |
G4-6 |
2 meters |
U6 |
G0-6 |
G5-0 |
2 meters |
U4 |
G0-4 |
G5-2 |
2 meters |
U2 |
G0-2 |
G5-4 |
2 meters |
U1 |
G0-0 |
G5-6 |
2 meters |
Footnote 1 Un is the unit location in the rack, where n is the number.
Table D-5 describes three-phase cabling from each power distribution unit (PDU) to the power supplies in the rack. The cables are terminated to PDU-A on the left, are routed to the right to enter the cable management arm (CMA), and are bundled in groups of four.
Table D-5 Three-Phase PDU Cabling
Rack UnitFoot 1 | PDU-A/PS-00 | PDU-B/PS-01 | Cable Length |
---|---|---|---|
U41 |
G5-6 |
G2-0 |
2 meters |
U39 |
G5-3 |
G2-3 |
2 meters |
U37 |
G5-0 |
G2-6 |
2 meters |
U35 |
G4-6 |
G1-0 |
2 meters |
U33 |
G4-4 |
G1-2 |
2 meters |
U31 |
G4-2 |
G1-4 |
2 meters |
U29 |
G3-6 |
G0-0 |
2 meters |
U27 |
G3-5 |
G0-1 |
2 meters |
U25 |
G3-3 |
G0-3 |
2 meters |
U24 |
G3-1 |
G0-5 |
2 meters |
U23 |
Not Applicable |
G5-0 |
Included |
U22 |
G2-5 |
G5-1 |
1 meter |
U21 |
G3-0 |
G0-6 |
2 meters |
U20 |
G2-4 |
G5-2 |
2 meters |
U18 |
G2-2 |
G5-4 |
2 meters |
U16 |
G1-6 |
G4-0 |
2 meters |
U14 |
G2-0 |
G5-6 |
2 meters |
U12 |
G1-4 |
G4-2 |
2 meters |
U10 |
G1-2 |
G4-4 |
2 meters |
U8 |
G1-0 |
G4-6 |
2 meters |
U6 |
G0-6 |
G3-0 |
2 meters |
U4 |
G0-4 |
G3-2 |
2 meters |
U2 |
G0-2 |
G3-4 |
2 meters |
U1 |
G0-0 |
G3-6 |
2 meters |
Footnote 1 Un is the unit location in the rack, where n is the number.
Table D-6 lists the location, ports, and cables for the InfiniBand connections from switch to switch. Figure D-2 identifies the locations of the ports on a Sun Network QDR InfiniBand Gateway switch.
Table D-6 InfiniBand Switch-to-Switch Cabling
From InfiniBand Switch Rack UnitFoot 1 | Port | To InfiniBand Switch Rack UnitFootref 1 | Port | Cable Length | Description |
---|---|---|---|---|---|
U20 |
9B |
U24 |
9A |
2 meters |
Leaf to leaf |
U20 |
10B |
U24 |
10A |
2 meters |
Leaf to leaf |
U20 |
11B |
U24 |
11A |
2 meters |
Leaf to leaf |
U20 |
8A |
U24 |
8A |
2 meters |
Leaf to leaf |
U20 |
9A |
U24 |
9B |
2 meters |
Leaf to leaf |
U20 |
10A |
U24 |
10B |
2 meters |
Leaf to leaf |
U20 |
11A |
U24 |
11B |
2 meters |
Leaf to leaf |
U1 |
0B |
U20 |
8B |
3 meters |
Spine to leaf |
U1 |
1B |
U24 |
8B |
3 meters |
Spine to leaf |
Footnote 1 Un is the unit location in the rack, where n is the number.
Figure D-2 Sun Network QDR InfiniBand Gateway Switch Ports
Table D-7 lists the location, ports, and cables for the InfiniBand connections from the leaf switches to the servers.
Table D-7 InfiniBand Switch-to-Server Cabling
From InfiniBand Switch Rack UnitFoot 1 | Port | To Rack UnitFootref 1 | PortFoot 2 | Cable Length |
---|---|---|---|---|
U24 |
0A |
U41 |
PCIe 3 P1 |
3 meters |
U24 |
0B |
U39 |
PCIe 3 P1 |
3 meters |
U24 |
1A |
U37 |
PCIe 3 P1 |
3 meters |
U24 |
1B |
U35 |
PCIe 3 P1 |
3 meters |
U24 |
2A |
U33 |
PCIe 3 P1 |
3 meters |
U24 |
2B |
U31 |
PCIe 3 P1 |
3 meters |
U24 |
3A |
U29 |
PCIe 3 P1 |
3 meters |
U24 |
3B |
U27 |
PCIe 3 P1 |
2 meters |
U24 |
4A |
U25 |
PCIe 3 P1 |
2 meters |
U20 |
0A |
U41 |
PCIe 3 P2 |
3 meters |
U20 |
0B |
U39 |
PCIe 3 P2 |
3 meters |
U20 |
1A |
U37 |
PCIe 3 P2 |
3 meters |
U20 |
1B |
U35 |
PCIe 3 P2 |
3 meters |
U20 |
2A |
U33 |
PCIe 3 P2 |
3 meters |
U20 |
2B |
U31 |
PCIe 3 P2 |
3 meters |
U20 |
3A |
U29 |
PCIe 3 P2 |
3 meters |
U20 |
3B |
U27 |
PCIe 3 P2 |
2 meters |
U20 |
4A |
U25 |
PCIe 3 P2 |
2 meters |
U20 |
4B |
U18 |
PCIe 3 P1 |
2 meters |
U20 |
12A |
U16 |
PCIe 3 P1 |
2 meters |
U20 |
12B |
U14 |
PCIe 3 P1 |
3 meters |
U20 |
13A |
U12 |
PCIe 3 P1 |
3 meters |
U20 |
13B |
U10 |
PCIe 3 P1 |
3 meters |
U20 |
14A |
U8 |
PCIe 3 P1 |
3 meters |
U20 |
14B |
U6 |
PCIe 3 P1 |
3 meters |
U20 |
15A |
U4 |
PCIe 3 P1 |
3 meters |
U20 |
15B |
U2 |
PCIe 3 P1 |
3 meters |
U24 |
4B |
U18 |
PCIe 3 P2 |
2 meters |
U24 |
12A |
U16 |
PCIe 3 P2 |
2 meters |
U24 |
12B |
U14 |
PCIe 3 P2 |
3 meters |
U24 |
13A |
U12 |
PCIe 3 P2 |
3 meters |
U24 |
13B |
U10 |
PCIe 3 P2 |
3 meters |
U24 |
14A |
U8 |
PCIe 3 P2 |
3 meters |
U24 |
14B |
U6 |
PCIe 3 P2 |
3 meters |
U24 |
15A |
U4 |
PCIe 3 P2 |
3 meters |
U24 |
15B |
U2 |
PCIe 3 P2 |
3 meters |
Footnote 1 Un is the unit location in the rack, where n is the number.
Footnote 2 Pn is the InfiniBand port, where n is the port number.