This chapter lists the various types of alarms that Oracle Communications Evolved Communications Application Server (OCECAS) generates.
Table 8-1 lists the alarms generated by the OCECAS application server subsystem on the Runtime nodes. The alarms are generated mainly for general session processing for all supported session protocols such as SIP, DIAMETER, SOAP and REST.
Alarm | Severity | Text | Cause | Resolution |
---|---|---|---|---|
SAS.-236841626 |
CRITICAL |
Session in state: {} so cannot send immediate response: {} ({}) |
Internal inconsistency |
Report software fault |
SAS.1358467794 |
CRITICAL |
Failed to find SIP session so cannot send SDP |
Internal inconsistency |
Report software fault |
SAS.1774975313 |
CRITICAL |
UAS Session in TERMINATED state so cannot send SDP |
Internal inconsistency |
Report software fault |
SAS.124500320 |
CRITICAL |
Invalid SIP session and/or endpoint state |
Internal inconsistency |
Report software fault |
SAW.807247288 |
CRITICAL |
Web service bean failed to send request |
Problem sending web request |
Check logs and network |
SAW.438621975 |
CRITICAL |
SOAP action failed to find SOAP transaction in Registry |
Internal inconsistency |
Report software fault |
SAS.-783315185 |
CRITICAL |
B2B Session in TERMINATED state so cannot send SDP |
Internal inconsistency |
Report software fault |
SAW.-2003283391 |
CRITICAL |
Web service bean failed to send request |
Problem sending web request |
Check logs and network |
SAW.-305625600 |
CRITICAL |
REST action failed to find REST transaction in Registry |
Internal inconsistency |
Report software fault |
Table 8-2 lists the alarms generated by the OCECAS application server Charging subsystem on the Runtime nodes.
Alarm | Severity | Text | Cause | Resolution |
---|---|---|---|---|
SC.461019824 |
CRITICAL |
Cannot send {} CCR because there is no RoSession established |
Internal inconsistency |
Check charging activities in control flow so report software fault |
SC.-610384092 |
CRITICAL |
OfflineCharging service: received invalid transaction |
Internal inconsistency |
Report software fault |
SC.1438229309 |
CRITICAL |
Could not send CCR: {} |
Problem sending charging request |
Check logs and network |
SC.1959791603 |
CRITICAL |
Cannot send {} because RoSession {} is already in progress |
Internal inconsistency |
Check charging activities in control flow so report software fault |
SC.-1759787268 |
CRITICAL |
Invalid ACR built from template: {} |
A charging template was configured incorrectly |
Retract the change set or fix charging template in a new change set |
SC.-1954822780 |
CRITICAL |
Failed to lookup off-line charging service '{}' |
Invalid charging service configuration |
Configure the charging service correctly |
SC.-510513429 |
CRITICAL |
Cannot send {} ACR because RfSession {} is in terminated state |
Internal inconsistency |
Check charging activities in control flow so report software fault |
SC.-1378210684 |
CRITICAL |
OnlineCharging service: received invalid transaction |
Internal inconsistency |
Report software fault |
SC.1545207092 |
CRITICAL |
Cannot send {} CCR because RoSession {} is in terminated state |
Internal inconsistency |
Check charging activities in control flow so report software fault |
SC.-2106093557 |
CRITICAL |
Could not send ACR: {} |
Problem sending charging request |
Check logs and network |
SC.-449017300 |
CRITICAL |
Cannot send {} because RfSession {} is already in progress |
Internal inconsistency |
Check charging activities in control flow so report software fault |
SC.103795138 |
CRITICAL |
Could not get diameter node from com.bea.wcp.diameter.Node attribute |
Invalid diameter configuration |
Check that a diameter network-access-point is defined |
SC.1191760828 |
CRITICAL |
Failed to populate charging template: {} |
A charging template was configured incorrectly |
Retract the change set or fix charging template in a new change set |
SC.1477636007 |
CRITICAL |
Cannot send {} ACR because there is no RfSession established |
Internal inconsistency |
Check charging activities in control flow so report software fault |
SC.1932756270 |
CRITICAL |
Invalid CCR built from template: {} |
A charging template was configured incorrectly |
Retract the change set or fix charging template in a new change set |
SC.1873110642 |
CRITICAL |
Could not get diameter node from com.bea.wcp.diameter.Node attribute |
Invalid diameter configuration |
Check that a Diameter network-access-point is defined |
SC.-284808798 |
CRITICAL |
Could not create an Online charging application |
Invalid diameter configuration |
Check Diameter configuration |
SC.-632290436 |
CRITICAL |
Failed to lookup on-line charging service '{}' |
Invalid charging service configuration |
Configure the charging service correctly |
SC.-1480789177 |
CRITICAL |
Could not send Diameter message: {} |
Problem sending charging request |
Check logs and network |
SC.-1333890964 |
CRITICAL |
Failed to populate charging template: {} |
A charging template was configured incorrectly |
Retract the change set or fix charging template in a new change set |
SC.288526327 |
CRITICAL |
Could not send Diameter message: {} |
Problem sending charging request |
Check logs and network |
Table 8-3 lists the alarms lists the alarms generated by the OCECAS application server subsystem on the Runtime nodes. The alarms are generated mainly for general session processing for all supported session protocols such as SIP, DIAMETER, SOAP and REST.
Alarm | Severity | Text | Cause | Resolution |
---|---|---|---|---|
SC.2119666489 |
CRITICAL |
Invalid engine state ID {} in response |
Internal inconsistency |
Report software fault |
SE.-259869001 |
CRITICAL |
Invalid configuration in control flow {} for activity {} and message: {} |
A control flow activity was configured incorrectly |
Retract the change set or fix control flow in a new change set |
SC.-1647253768 |
CRITICAL |
Failed to load control flow key for protocol: '{}' and method: '{}' |
There is no application trigger configured for the specified protocol and method |
Ensure that the database contains a valid application trigger entry |
Table 8-4 lists the alarms generated by the OCECAS application server Media subsystem on the Runtime nodes.
Alarm | Severity | Text | Cause | Resolution |
---|---|---|---|---|
SM.-1340286052 |
CRITICAL |
Failed to initialise MediaParticipant: {} |
Can't process media transaction |
Check the media server is available |
SM.917837316 |
CRITICAL |
Invalid media server configuration: {} |
Can't process media transaction |
Configure the media server correctly |
Table 8-5 lists the alarms generated by the OCECAS application server UDR subsystem on the Runtime nodes.
Alarm | Severity | Text | Cause | Resolution |
---|---|---|---|---|
SA.73957577 |
CRITICAL |
Failed to update UDR |
UpdateProfile failed |
Check log for more information |
SU.-852056064 |
CRITICAL |
handleProfileNotification: session has null transaction |
Internal inconsistency |
Report software fault |
SU.-1967106361 |
CRITICAL |
Failed to create UDR update request |
Internal inconsistency |
Report software fault |
SU.-756848176 |
CRITICAL |
Failed to send UDR read request: {} |
Problem sending UDR request |
Check logs and network |
SU.1546249155 |
CRITICAL |
Failed to send UDR update request: {} |
Problem sending UDR request |
Check logs and network |
SU.-561858002 |
CRITICAL |
UDR handler '{}' returned null service |
Invalid UDR service configuration |
Configure the UDR service correctly |
SU.-1400801029 |
CRITICAL |
Failed to create UDR request builder |
Internal inconsistency |
Report software fault |
SU.-208267932 |
CRITICAL |
handleUpdateResponse: called with null response |
Internal inconsistency |
Report software fault |
SU.837283091 |
CRITICAL |
handleReadResponse: session has null transaction |
Internal inconsistency |
Report software fault |
SU.1109342659 |
CRITICAL |
handleUpdateResponse: response has null session |
Internal inconsistency |
Report software fault |
SU.-29369338 |
CRITICAL |
handleUpdateResponse: session has null transaction |
Internal inconsistency |
Report software fault |
SU.2053540822 |
CRITICAL |
handleReadResponse: response has null session |
Internal inconsistency |
Report software fault |
SU.1699875721 |
CRITICAL |
handleReadResponse: transaction has null app session id |
Internal inconsistency |
Report software fault |
SU.1517428308 |
CRITICAL |
Failed to create UDR read request |
Internal inconsistency |
Report software fault |
SU.1670068532 |
CRITICAL |
handleProfileNotification: event has null session |
Internal inconsistency |
Report software fault |
SU.735930231 |
CRITICAL |
handleReadResponse: called with null response |
Internal inconsistency |
Report software fault |
SU.397693795 |
CRITICAL |
handleProfileNotification: called with null event |
Internal inconsistency |
Report software fault |
Table 8-6 lists the alarms generated by the OCECAS application server Web Service subsystem on the Runtime nodes.
Alarm | Severity | Text | Cause | Resolution |
---|---|---|---|---|
SW.2044210026 |
CRITICAL |
Failed to find the transaction. |
Internal inconsistency |
Report software fault |
SW.2035879783 |
CRITICAL |
Unable to Construct REST client. REST client actions will be unavailable. |
Problem sending web request |
Check logs and network |
SW.609982854 |
CRITICAL |
Unable to perform REST client action because there is no REST client. |
Problem sending web request |
Check logs and network |
SW.153863372 |
CRITICAL |
Web session: received invalid transaction |
Internal inconsistency |
Report software Check |
SW.1380968501 |
CRITICAL |
Web session: received invalid transaction |
Internal inconsistency |
Report software fault |
SW.-335797324 |
CRITICAL |
Received REST Error response: {} |
Web request failed |
Check logs and network |
SW.-110818330 |
CRITICAL |
Invalid WS response context so ignoring JAX-WS response. |
Internal inconsistency |
Report software fault |
SW.-650174813 |
CRITICAL |
Web handler '{}' returned null service |
Invalid web service configuration |
Configure the web service correctly |
SW.-27831726 |
CRITICAL |
Web handler '{}' returned null service2 |
Invalid web service configuration |
Configure the web service correctly |
SW.-1023652141 |
CRITICAL |
Failed to find the transaction. |
Internal inconsistency |
Report software fault |