Editing MCC Ranges

Use this task to change MCC Ranges.

MCC Ranges fields are described in MCC Ranges Elements.

When the Diameter Common > Network Identifiers > MCC Ranges [Edit] page opens, the fields are populated with the current configured values.

  1. On the SOAM, select Diameter Common > Network Identifiers > MCC Ranges.

    The Diameter Common > Network Identifiers > MCC Ranges page appears.

  2. Select the MCC Range to be changed.
  3. Click the Edit button.

    The Diameter Common > Network Identifiers > MCC Ranges [Edit] page appears.

  4. Change the Start MCC value, the End MCC value, or both.

  5. Click:
    • OK to save the changes and return to the Diameter Common > Network Identifiers > MCC Ranges page.
    • Apply to save the changes and remain on this page.
    • Cancel to return to the Diameter Common > Network Identifiers > MCC Ranges page without saving any changes.

    If OK or Apply is clicked and any of the following conditions exist, an error message appears:

    • The selected MCC Range no longer exists; it has been deleted by another user
    • Any field contains values that are out of range
    • Any required field is empty (not entered)
    • The Start MCC field value is greater than the End MCC field value
    • The MCC Range created lies within the ranges of other MCC Ranges