Select a value for the Critical Alarm Threshold percent. This determines the ingress message rate threshold for this alarm to be raised as Critical. The default is 95 percent.
Select a value for the Critical Alarm Clear percent. This determines the ingress message rate clear for this alarm to be raised as Critical. The default is 90 percent.
Select a value for the Major Alarm Threshold percent. This determines the ingress message rate threshold for this alarm to be raised as Major. The default is 80 percent.
Select a value for the Major Alarm Clear percent. This determines the ingress message rate clear for this alarm to be raised as Major. The default is 70 percent.
Select a value for the Minor Alarm Threshold percent. This determines the ingress message rate threshold for this alarm to be raised as Minor. The default is 60 percent.
Select a value for the Minor Alarm Clear percent. This determines the ingress message rate clear for this alarm to be raised as Minor. The default is 50 percent.
Click:
Apply to save the Alarm Settings changes and refresh the page to show the changes.
Cancel to discard the changes and refresh the page.
If Apply is clicked and any of the following conditions exist, an error message appears:
Any fields contain a value that contains invalid characters or is out of the allowed range.
A Critical Alarm Clear value is greater than the Critical Alarm Threshold.
A Major Alarm Clear value is greater than the Major Alarm Threshold.
A Minor Alarm Clear value is greater than the Minor Alarm Threshold.
A Major Alarm Threshold value is greater than the Critical Alarm Clear or Critical Alarm Threshold.
A Minor Alarm Threshold value is greater than the Major Alarm Clear or Major Alarm Threshold.