RxFabrUnkApplId

Measurement Group: Full Address Resolution Performance

Measurement Type: Simple

Measurement Dimension: Single

Description: Number of Request messages rejected due to an unknown Application ID.

Collection Interval: 5 min

Peg Condition: For each routing exception when the Application ID is not valid.

Measurement Scope: Server Group

Recovery:

  1. The currently provisioned Diameter Application IDs can be viewed in the FABR Configuration & Maintenance GUI.
  2. The currently provisioned Application Routing Rules can be viewed using Main Menu > Diameter > Configuration > Application Routing Rules.
  3. Contact My Oracle Support (MOS) for assistance.