Measurement Group: MD-IWF Performance
Measurement Dimension: Single
Measurement Type: Simple
Description: The total number of MAP-to-Diameter transaction messages by MD-IWF.
Collection Interval: 5 min
Peg Condition: Each time MD-IWF receives a MAP request message from the SS7 network and each subsequent message that MD-IWF receives in the MAP-to-Diameter transaction.
Note: For example, MD-IWF could receive a CancelLocationArg from the SS7 network, send a Diameter CLR to a DA-MP, receive a Diameter CLA from a DA-MP, and send a CancelLocationRes to the SS7 network. In this example, there are 2 messages that are pegged in the MAP-to-Diameter transaction.
Note: This measurement serves as a baseline for calculating measurements
RxMap2DiamTransMsgRateAvg and
RxMap2DiamTransMsgRatePeak as well as KPI MAP-to-Diameter Ingress Msg Rate found in KPI MAP-to-Diameter Trans Msg Rate (refer to the
DSR Alarms and KPIs Reference for details about this KPI).
Measurement Scope: Site
Recovery: