RxMdIwfComAgentError

Measurement Group: MD-IWF Exception

Measurement Dimension: Single

Measurement Type: Simple

Measurement Description: The number of Diameter Request messages sent to DA-MP that results in ComAgent error / timeout or in DM-IWF NACK

Collection Interval: 5 min

Peg Condition: Each time MD-IWF sends a Diameter Request message to DM-IWF that results in a ComAgent error / timeout or in a DM-IWF NACK.

Measurement Scope: Site

Recovery:

No action required.