TxMdIwfDiamEdlEncodeFailure

Measurement Group: MD-IWF Exception

Measurement Dimension: Single

Measurement Type: Simple

Description: Number of times an EDL failure occurred while MD-IWF attempted to encode a Diameter message

Peg Condition: This measurement is pegged each time MD-IWF attempts to encode a Diameter message to be sent to a DA-MP, but an EDL encode failure occurs. Event 33080 - EDL failure occurred while MD-IWF attempted to encode a Diameter message (refer to the DSR Alarms and KPIs Reference for details about this event) will be raised when this condition occurs.

Collection Interval: 5 min

Measurement Scope: Site

Recovery:

  1. If the encode failure is due to Diameter message size - the failure reason can be determined from Event 33080 - EDL failure occurred while MD-IWF attempted to encode a Diameter message (refer to the DSR Alarms and KPIs Reference for details about this event) - it may be necessary to increase the engineering configurable parameter (DiameterMaxMessageSize in table MapIwfLongConfig) for maximum Diameter message size.
  2. Contact My Oracle Support (MOS) for assistance if this measurement is being pegged frequently.