RxGyRoReqDiscardedCongestionPerCmd

Measurement Group: OC-DRA Congestion Exception

Measurement Type: Simple

Measurement Dimension: Arrayed (by Diameter Request Command Abbreviation i.e. CCR-I/U/T/E, RAR, and "Total")

Description: The number of Gy/Ro Diameter Credit Control Application Request messages discarded due to congestion.

Collection Interval: 5 min

Peg Condition: Each time a Gy/Ro Diameter Credit Control Application Request message is discarded due to congestion.
Note: This measurement is pegged twice, once for the 3-digit error code and once for "Total".

Measurement Scope: All

Recovery:

This measurement represents an exception condition in which Gy/Ro Diameter Credit Control Application Request messages are discarded due to congestion. This condition causes Event 22707 Diameter Message Processing Failure to be generated. Refer to the DSR Alarms and KPIs Reference for details on Event 22707