EvTrSockInitFail

Measurement Group: Association Exception

Measurement Type: Simple

Description: The number of times the socket initialization failed. Socket initialization includes configuring the association according to the settings in the GUI under SS7/Sigtran >Configuration>Associations>Configuration Sets.

Collection Interval: 30 min

Peg Condition: This measurement is incremented by one each time one or more socket options cannot be set according to the settings in the association’s configuration set.

Measurement Scope: NE, Server

Recovery:

  1. This measurement should have a zero value. A non-zero value indicates a problem with the association setup prior to attempting to connect the association. If this occurs, look for Event ID 19221 in the GUI under Alarms & Events>View History. Event 19221 provides details about the configuration failure.
  2. Contact My Oracle Support (MOS) for further assistance.