RxTrFarEndClose

Measurement Group: Association Exception

Measurement Type: Simple

Description: Number of times the far end closed the SCTP connection

Collection Interval: 30 min

Peg Condition: This measurement is incremented by one each time the far-end of the association closes the association by sending either SHUTDOWN or ABORT.

Measurement Scope: NE, Server

Recovery:

  1. If the closing of the association was expected, no further action is necessary, the association will be recovered as soon as the far-end is ready to connect again. If the closing of the association was not expected. You can view Association status from the GUI main menu under SS7/Sigtran>Maintenance>Associations.
  2. Look in the event history from the GUI main menu under Alarms & Events>View History for Event ID 19224 to determine exactly when the far-end closed the association.
  3. Look for other events for the association or MP server in the event history.
  4. Verify that IP connectivity still exists between the MP server and the SG.
  5. Verify whether the far-end of the association is undergoing maintenance.
  6. Contact My Oracle Support (MOS) for assistance if needed.